Electrical permit history — 6363 S Country Club Rd

6363 S Country Club Rd, Tucson — built 1989, with 44 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6363 S Country Club Rd

Built 1989 — 1980s commercial stock · 44 permits on record; no permitted panel/service or HVAC work among them

Parcel
14029037D
Built
1989 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Warehouse W/ Office/ Retail
Parcel size
3.55 acres
Building area
49,941 sq ft (assessor record)
Sewer
Connection on file (1996, 2007, 2024) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 6363 S Country Club Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fence / wall permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fence / wall permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0325-00211 — Pull and plug 3 existing pendent sprinklers to accommodate removed interior walls.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    A pool or spa was permitted in 2024. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2025-03-12 (TF-FCP-0325-00211) — Pull and plug 3 existing pendent sprinklers to accommodate removed interior walls..

Permit history (44)

Permit history for this parcel — 8 of 44 records
DateRecordWhatStatusValue
2025-03-12finaledTF-FCP-0325-00211City permit recordFence / wallPull and plug 3 existing pendent sprinklers to accommodate removed interior walls.Complete
2024-11-08finaledTC-COM-1124-02160City permit recordPool / spaINTERIOR TENANT IMPROVEMENT ONLY. WORK TO INCLUDE INTERIOR DEMOLITION, NEW OFFICE SPACE, AND EXISTING WAREHOUSE. MECHANICAL AND PLUMBING TO BE REWORKED TO FIT NEW LAYOUT. LIGHTING TO REMAIN AS IS.Complete
2023-02-07finaledTR-ROW-0223-00345City permit recordRight-of-Way (ROW)A charity car show, road closures of Transcon Way between Country Club Rd and E. Hemisphere Lp. Traffic control: 7Am setup take down 7pmComplete
2023-02-05TR-ROW-0223-00334City permit recordRight-of-Way (ROW)We are Having a charity car show for Tucson charities we will be closing down. This area will be used as a show are for the vehicles entering in the show. We will only be doing the event for one day.Void
2023-02-05finaledTR-ROW-0223-00335City permit recordRight-of-Way (ROW)The event is a car show for charity heled at the above location and we intend to Clouse down E. Transcon way form Country Club Rd to E. Hemisphere Loop. We will be parking cars on the street as a display area for the show.Complete
2022-11-09finaledTF-FOP-1122-00061City permit recordFire OperationalHigh-Piled storage in theatre scenery shop Prop Storage area.Complete
2022-10-04finaledT22FC00686City permit recordFire ConstructionAutomatic Fire Extingshing Sys - NFP to modify the existing fire sprinkler system.; Commercial Fire Sprinkler Systems - Modification of heads: 45Complete
2022-08-15finaledDP22-0236City permit recordDevelopment PackageSite - Arizona Theatre Company. Add interior mezzanine square footage.Complete
Show 36 older records
Permit history for this parcel — remaining 36 records
DateRecordWhatStatusValue
2022-06-27finaledT22CM04862City permit recordCommercial BuildingTI: Office/FactoryComplete
2022-05-04finaledT22CM03382City permit recordCommercial Buildingreplace wire in main serviceComplete
2022-01-19finaledT22CM00374City permit recordCOMBOelectric service reconnectFinal
2020-11-24finaledT20RW06308City permit recordROW3392-2-AT CORNER OF E. WELDING RD AND S. COUNTRY CLUB RD ACCESS MH 14714 TO SPLICE EXISTING. ADDRESS ON APPLICATION: 2943 E WIEDING RDFinal
2016-03-21finaledT16CM02105City permit recordCOMBONEW 200A CIRCUIT FOR OVENFinal
2016-02-16finaledT16CM01081City permit recordCOMBOTI: Install Process OvenL of c
2015-10-14T15CM07112City permit recordCOMBOT.I;OFFICEWithdrwn
2014-11-13expired 2015-05-25T14CM07753City permit recordCOMBOTI: OFFICEWithdrwn
2013-06-17expired 2013-08-16T13EX00836City permit recordEXCAVPOT HOLE ASPHALT ON CURB 3 X 7 TO REPAIR FIBER CONDUIT ON TRANSCON WAY.Closed
2012-05-11finaledT12BU00613City permit recordSPKLRAdd 46 fire sprinklersFinal
2012-03-01finaledT12CM00789City permit recordCOMBOTI: OFFICE BUILDINGC of o
2009-06-18finaledT09BU00887City permit recordSPKLRRelocate 1 fire sprinklerFinal
2008-05-21expired 2008-11-24T08BU00948City permit recordSPKLRAdd 8 new fire sprinkler heads.Expired
2007-04-12T07CM01534City permit recordCOMBOTI:OFFICEWithdrwn
2007-02-16finaledT07BU00384City permit recordSPKLRAdd two headsFinal
2005-11-08finaledT05OT02783City permit recordSIGN10033Final
2005-08-03finaledT05OT01911City permit recordSIGNSIGN: 9459 CHAMBERLAIN GROUPFinal
2005-07-11T05AN00745City permit recordADDRNEWIssued
2005-07-11finaledT05OT01698City permit recordC-OF-OC OF OC of o
2005-02-11finaledT05BU00314City permit recordSPKLRSPRINKLER:FIRE ADD 45Final
2005-02-11finaledT05OT00321City permit recordSIGNSIGN:8504 CHAMBERLAIN GROUPFinal
2005-01-06finaledT05BU00040City permit recordBUILDINSTALL:PALLET RACKINGFinal
2004-12-22finaledT04BU03035City permit recordSPKLRFIRE SPKR:RELOCATE 4 & ADD 46Final
2004-11-18T04AN01108City permit recordADDRNEWIssued
2004-11-18finaledT04CM05105City permit recordCOMBOTI:OFFICEC of o
2003-07-10finaledT03CM03373City permit recordCOMBOTI:OPTICALC of o
2003-04-01finaledT03BU00821City permit recordSPKLRFIRE SPKR:ADD 8Final
2002-03-18finaledT02BU00840City permit recordSPKLRFIRE SPKR:ADD 11 & RELOCATE 2Final
2001-11-02finaledT01OT00844City permit recordSIGNSIGN:3254Final
2001-10-01finaledT01CM04878City permit recordCOMBOTI:FACTORYFinal
1999-06-29T99BU01751City permit recordTEMP-FBBTEMP CLASSROOM TRAILERWithdrwn
1999-02-11finaledT99ME00181City permit recordMECHPRESSURE VESSEL CERTIFICATE:TUC-24678,24677,24676Final
1998-10-01T98BU02414City permit recordTANKSTANKS:200 GALLONSWithdrwn
1998-09-08expired 1999-03-21T98CM03851City permit recordFence / wallMECHANICAL EQUIEMENT FOUNDATION PAD FOR COOLING TOWER AND GAS ENGINE AND 8 FENCE (CHAINLINK) X 70,10 X 29 PAD.Expired
1998-05-08finaledT98BU01159City permit recordSPKLRFIRE SPKR:RELOC 14 & ADD 4Final
1997-12-22T97CM04195City permit recordCOMBOTI:OFFICEWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2008-11-12T08FR04296Code enforcement caseFireField
2007-04-10T07FR00694Code enforcement caseCode enforcement caseField
2005-07-29T05VL00651Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14029037D — 44 permits on file from 1997 to 2025 (11 combo, 9 spklr, 4 sign, 3 right-of-way (row)) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.