Electrical permit history — 3321 E Global Lp
3321 E Global Lp, Tucson — built 1995, with 49 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3321 E Global Lp
Built 1995 — 1990s commercial stock · last permitted panel/service work 2022 (permitted, completion not confirmed)
Permanent link: Electrical permit history for 3321 E Global Lp (aztucsonelectricalsolutions.com/property/140290280/3321-e-global-lp-tucson-az-85706) · Public records last checked 2026-08-16
- Parcel
- 140290280
- Built
- 1995 (county record)
- Jurisdiction
- Tucson
- Zoning
- I-1
- Assessor use
- Office Building 1 Story
- Parcel size
- 3.41 acres
- Building area
- 37,824 sq ft (assessor record)
- Sewer
- Connection on file (2002) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- A 2022 permit was issued; completion is not confirmed in the available record; the permit description states “Install 600kw NG generator with new ATS and switchgear. Underground electric conduit and electrical infrastructure for new UPS in IT closets”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionPermitted — completion not confirmedA 2022 permit specifies this work (the permit description states “Install 600kw NG generator with new ATS and switchgear. Underground electric conduit and electrical infrastructure for new UPS in IT closets”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: last recorded inspection 2024-06-20; no approved final is shown. TC-COM-1122-00050 — Install 600kw NG generator with new ATS and switchgear. Underground electric conduit and electrical infrastructure for new UPS in IT closets
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2005 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2016 (10 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T16BU01193 — SPRINKLER
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Recorded sales (4)
| Date | Price | Type |
|---|---|---|
| 2022-05-09 | $13,893,950 | Warranty Deed |
| 2017-06-30 | $13,500,000 | Warranty Deed |
| 2014-12-29 | $2,697,828 | Warranty Deed |
| 2005-08-04 | $7,500,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2023-08-02 (TR-UTL-0823-02187) — (1) 5' x 5' bell hole in pavement..
Permit history (49)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-08-02finaled | TR-UTL-0823-02187City permit record | Right-of-Way (ROW) - Utility(1) 5' x 5' bell hole in pavement. | Complete | |
| 2022-11-04expired 2024-12-17 | TC-COM-1122-00050City permit record | Commercial BuildingInstall 600kw NG generator with new ATS and switchgear. Underground electric conduit and electrical infrastructure for new UPS in IT closets | Issued | |
| 2016-08-19finaled | T16BU01193City permit record | SPKLRSPRINKLER | Final | |
| 2016-07-27finaled | T16CM05884City permit record | Fence / wallDEMISING WALL BETWEEN 2 SUITES | Final | |
| 2016-06-28finaled | T16BU00982City permit record | DEMODEMO ONLY | Final | |
| 2016-05-31finaled | DP16-0092City permit record | Development PackageRAYTHEON GLOBAL LOOP: COMMERCIAL PARKING | Complete | |
| 2015-01-16 | T15BU00035City permit record | BUILDFIRE ALARM | Withdrwn | |
| 2009-10-21finaled | T09BU01567City permit record | BUILDSTRUCTURAL ROOF REPAIR | Final |
41 older records are not shown here. — each links to its official file.
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2011-03-09finaled | T11FR00597Code enforcement case | Code enforcement case | Complete |
| 2009-02-05finaled | T09FR00522Code enforcement case | Fire | Complete |
| 2008-05-07 | T08FR01140Code enforcement case | Code enforcement case | Field |
| 2008-05-07 | T08FR01145Code enforcement case | Code enforcement case | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 140290280 — 49 permits on file from 1997 to 2023 (17 spklr, 8 regplant, 4 build, 4 combo) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.