Electrical permit history — 3105 E Valencia Rd

3105 E Valencia Rd, Tucson — built 1983, with 25 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3105 E Valencia Rd

Built 1983 — 1980s commercial stock · 25 permits on record; no permitted panel/service or HVAC work among them

Parcel
14029008B
Built
1983 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Restaurant Fast Food
Parcel size
0.58 acres
Building area
2,390 sq ft (assessor record)
Sewer
Connection on file (1996) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3105 E Valencia Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire operational permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire operational permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2019 (7 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T19FC00654 — (1) HOOK UP ANSUL SUPPRESSION SYSTEM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Most recent permit on record for this parcel: 2025-04-10 (TR-ROW-0425-00496) — The contractor will be installing cameras onto light poles for the Tucson Police Department. Shadow Truck less than an hour per location. 60 day Permit..

Permit history (25)

Permit history for this parcel — 8 of 25 records
DateRecordWhatStatusValue
2025-04-10finaledTR-ROW-0425-00496City permit recordRight-of-Way (ROW)The contractor will be installing cameras onto light poles for the Tucson Police Department. Shadow Truck less than an hour per location. 60 day Permit.Complete
2023-02-13TF-FOP-0223-00501City permit recordFire OperationalVOID-PLEASE SUBMIT GENERAL OPERATIONAL PERMIT - PLACES OF ASSEMBLY PERMIT - YOU ALREADY HAVE COMPRESSED GASES PERMIT - Compressed GasesVoid
2023-01-20finaledTF-FOP-0123-00388City permit recordFire OperationalCompressed Gases PermitComplete
2023-01-19TF-FOP-0123-00373City permit recordFire OperationalVOID-RESUBMITTED PERMIT#TF-FOP-0123-00388-Compressed Gases PermitVoid
2022-12-14TF-FOP-1222-00231City permit recordFire OperationalVOID-Resubmitted Permit#TF-FCP-0123-00373-Places of Assembly Permit neededVoid
2020-04-17finaledT20RW02228City permit recordROW(2) 5X5 BELLHOLES IN DIRT FRONT -- TO REPAIR/REPLACE GAS LINE ISSAP NPLFinal
2019-08-19finaledT19FC00654City permit recordFIRECONS(1) HOOK UP ANSUL SUPPRESSION SYSTEMFinal
2019-07-17finaledT19OT00658City permit recordSIGN10 sign rebrandFinal
Show 17 older records
Permit history for this parcel — remaining 17 records
DateRecordWhatStatusValue
2019-07-02expired 2020-02-05T19CM04740City permit recordFence / wallT19DV05199 - WALL REPAIRExpired
2019-06-28finaledT19RW03692City permit recordROW(2) 5x5 IN DIRT/CONCRETE ON COUNTRY CLUB RD TO POTHOLE GAS LINEFinal
2019-05-20finaledT19CM03538City permit recordCOMBOTI: MCDONALDSFinal
2019-05-15DS19-06City permit recordZoning Verification LetterMCDONALDS - COUNTRY CLUB & VALENCIA - TSMR, TSM Section 7-01-03.3.A (sidewalk/ADA access).Approved
2019-05-03finaledDP19-0112City permit recordDevelopment PackageSITE/GRADING - McDonalds USA, LLC, commercial restaurant.Complete
2018-05-03finaledT18FO00370City permit recordFIREOPERINSTALL CO2 ALARM SYSTEM FOR BULK CO2Final
2017-05-23finaledT17FO00454City permit recordFIREOPERPermit for Class IIIB Oil StorageFinal
2017-05-23finaledT17FO00455City permit recordFIREOPERPermit for CO2 Beverage SystemFinal
2017-05-18finaledT17FO00436City permit recordFIREOPERPermit for Place of AssemblyFinal
2008-10-01expired 2010-05-12T08CM03244City permit recordCOMBOTI:MCDONALDS RESTAURANTExpired
2006-03-17expired 2006-10-25T06CM01476City permit recordCOMBODINING RM REMODELClosed
2003-06-27finaledT03OT01164City permit recordSIGNSIGN:5724Final
2003-05-30finaledT03OT00975City permit recordSIGNSIGN:# 5598Final
1999-12-27T99OT00357City permit recordSITESITE:INCREASE SEATING AREAWithdrwn
1999-03-16T99OT00071City permit recordSITESITE:INCREASE SEATING AREAWithdrwn
1998-08-11finaledT98BU01950City permit recordAddition / alterationADDITION:FLAGPOLEFinal
1998-07-09expired 1998-09-07T98EX00772City permit recordEXCAVEXCAV:30 DRIVE APRONClosed

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2019-06-27T19DV05199Code enforcement caseCode enforcement caseComplian
2015-02-11T15DV00894Code enforcement caseCode enforcement caseComplian
2013-05-09T13DV03195Code enforcement caseCode enforcement caseNoverify
2011-01-19finaledT11FR00180Code enforcement caseCode enforcement caseComplete
2011-01-12T11FR00119Code enforcement caseFireField
2008-07-16finaledT08FR01953Code enforcement caseCode enforcement caseComplete
2007-12-03finaledT07FR02455Code enforcement caseCode enforcement caseComplete
2004-03-04T04ZV00130Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14029008B — 25 permits on file from 1998 to 2025 (4 fire operational, 4 fireoper, 3 sign, 3 combo) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.