Electrical permit history — 1430 E Wieding Rd

1430 E Wieding Rd, Tucson — built 1973, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1430 E Wieding Rd

Built 1973 — 1970s commercial stock · last permitted panel/service work 2012 (finaled)

Parcel
14024079B
Built
1973 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Manufacture Durable/Nondurable Goods
Parcel size
4.59 acres
Building area
35,929 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2012 permit was finalized; the permit description states “ADD (3) TEMP GENERATORS R3: INSTALL/REPAIR ELECTRICAL SERVICE”.

See the property

County aerial photograph centered on 1430 E Wieding Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2012 (14 years ago). City inspection record: ELECTRIC - FINAL approved 2012-02-21. Contractor of record: FAULK ELECTRIC CORPORATION. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T12EL00066 — ADD (3) TEMP GENERATORS R3: INSTALL/REPAIR ELECTRICAL SERVICE
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2016 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onA newer 2012 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Add 2 fire sprinklers”. Last permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU00081 — Add 12, relocate 2 fire sprinklers
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    A pool or spa was permitted in 2018. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2023-07-03$2,497,800Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2024-10-22 (TS-PRM-1024-00468) — Lexan Sign Panel - Change of Copy.

Permit history (19)

Permit history for this parcel — 8 of 19 records
DateRecordWhatStatusValue
2024-10-22TS-PRM-1024-00468City permit recordSign - PermanentLexan Sign Panel - Change of CopyExpired
2023-03-29finaledTZ-CMP-0323-00092City permit recordZoning Verification LetterZoning LetterComplete
2019-01-25finaledT19RW00423City permit recordROWJOB REQUIRES ACCESS TO MH # 6955 AT 1401 E VALENCIA RD., MH # 8167 AT 1700 E VALENCIA RD AND MH # 7512 AT 1701 E VALENCIA RD . ACCESS REQUIRED TO TO SPLICE FIBER.Final
2018-10-03finaledT18OT01045City permit recordFence / wallchange of copy-1 ILLUM wallFinal
2018-06-15finaledT18RW02687City permit recordPool / spaStarting on the S/E corner of E. Valencia Rd and S. Del Moral Blvd at TEP pole Overlash 875 coax South 51' and tie in mid span to New Strand. From TEP Pole South of S. Del Moral Blvd on the North side of E. Valencia Rd attach New 875 coax and New Strand going West for 598', riser down pole and Trench/ Bore North 15' to Out Of Row.Final
2017-06-09expired 2017-12-06T17CM04510City permit recordCOMBO12 X 12 METAL SHADE COVERExpired
2017-02-15T17CM01268City permit recordCOMBODETACHED CARPORTWithdrwn
2016-08-31finaledT16CM06703City permit recordAddition / alterationSTORAGE ADDITION TO EXISTING STORAGE; COMMFinal
Show 11 older records
Permit history for this parcel — remaining 11 records
DateRecordWhatStatusValue
2016-08-08expires 2026-11-13DP16-0133City permit recordDevelopment PackageSITEIssued
2012-01-20finaledT12PL00114City permit recordPLUMBGAS RECONNECTION - COMM (APA) R1 - GAS LINE REPAIRFinal
2012-01-18expired 2012-07-16T12BU00085City permit recordSPKLRAdd 2 fire sprinklersExpired
2012-01-11expired 2012-07-09T12BU00030City permit recordBUILDREPL FIRE DAMAGE METAL SHEATHING (T12DV00131)Expired
2012-01-09finaledT12EL00066City permit recordELECTADD (3) TEMP GENERATORS R3: INSTALL/REPAIR ELECTRICAL SERVICEFinal
2010-10-12finaledT10CM02824City permit recordCOMBOTEST FIELD FOR 80 PANEL PV SYSTEMFinal
2009-01-20finaledT09BU00081City permit recordSPKLRAdd 12, relocate 2 fire sprinklersFinal
2008-12-11expired 2010-01-25T08CM03863City permit recordFence / wallTI: PLANT (GE WALL EXTENSION AND NEW PIT) R1 -Si_xpire
2008-11-17finaledT08CM03702City permit recordAddition / alterationADDITION:CANOPY:SHED (PREFAB) TWO SHEDS 12'X12' AND 16'X55'Final
2008-11-10finaledT08CM03637City permit recordAddition / alterationADDITION:REPAIR SHOPFinal
2008-10-01finaledT08BU01760City permit recordBUILD9 NEW FIRE SPRINKLER HEADSFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2014-10-22T14DV08847Code enforcement caseCode enforcement caseComplian
2013-08-21T13DV06217Code enforcement caseElectricalComplian
2013-05-09T13DV03179Code enforcement caseCode enforcement caseNoverify
2012-01-09T12DV00131Code enforcement caseFireComplian
2010-01-06finaledT10FR00033Code enforcement caseCode enforcement caseComplete
2009-07-31T09DV04443Code enforcement caseSignNoverify
2009-05-06finaledT09FR01557Code enforcement caseCode enforcement caseComplete
2008-02-19T08DV01197Housing code violationILLEGAL DUMPINGrecorded before 2023COMPLIAN

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14024079B — 19 permits on file from 2008 to 2024 (3 combo, 3 addition / alteration, 2 fence / wall, 2 spklr) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.