Electrical permit history — 1145 E Valencia Rd

1145 E Valencia Rd, Tucson — built 2002, with 23 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1145 E Valencia Rd

Built 2002 — 2000s commercial stock · 23 permits on record; no permitted panel/service or HVAC work among them

Parcel
14024073E
Built
2002 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Multiuse Or Miscellaneous Industrial
Parcel size
5.38 acres
Building area
38,828 sq ft (assessor record)
Sewer
Connection on file (2018) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1145 E Valencia Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onLast permitted 2007 (19 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T07BU00326 — Add 5 fire sprinklers
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    There is an electrical reconnect permit from 2019. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2024-09-18 (TR-UTL-0924-01795) — wo2678346 1145 e valencia rd 15-14-07 sw remove device in water line in asphalt 4lf/ar.

Permit history (23)

Permit history for this parcel — 8 of 23 records
DateRecordWhatStatusValue
2024-09-18finaledTR-UTL-0924-01795City permit recordRight-of-Way (ROW) - Utilitywo2678346 1145 e valencia rd 15-14-07 sw remove device in water line in asphalt 4lf/arComplete
2020-07-16T20CM04504City permit recordCommercial BuildingREPLACEING A DAMAGED PRV VALVEApproved
2019-05-08finaledT19CM03311City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
2017-03-21T17CM02250City permit recordCOMBORELOCATE POWER PEDESTALWithdrwn
2016-11-22expired 2017-05-21T16OT01401City permit recordFence / wall1- NON ILLUM WALL SIGNExpired
2015-11-12finaledT15CM07898City permit recordAddition / alterationINSTALL ADDITIONAL SERVICE TO EXISTING 480, 3 PHASEFinal
2015-05-06expired 2015-11-18T15OT00609City permit recordFence / wall1- METAL WALL SIGNExpired
2014-04-11finaledT14OT00458City permit recordFLOODPLNFUP - T14CM01990Final
Show 15 older records
Permit history for this parcel — remaining 15 records
DateRecordWhatStatusValue
2014-04-09expired 2021-08-08DP14-0052City permit recordDEVPKGSITEClosed
2014-04-09finaledT14CM01990City permit recordAddition / alterationTI: ADDITION OF OFFICES TO WAREHOUSEFinal
2013-12-23expired 2023-04-05T13BU01441City permit recordSPKLRFIRE SPRINKLERSClosed
2013-12-23T13CM07754City permit recordCOMBOFIRE ALARMWithdrwn
2012-08-15expired 2021-08-08DP12-0133City permit recordPool / spaPARKING LOT RESTRIPE TO ADD ADDITIONAL PARKING SPACESClosed
2012-08-15expired 2014-03-09T12CM05036City permit recordCOMBOTI:TUCSON ROLLER DERBYWithdrwn
2010-06-04finaledT10EL01343City permit recordELECTELECTRIC:RECONNECT CORRECTION: PEDASTAL ON AN EMPTY LOT FOR TEMPORARY SECURITY RVFinal
2009-12-04expired 2010-12-04T09OT02614City permit recordPEDDLERBAGS N'MORE/ SELLING DECALS/GIFTS ITEMSExpired
2007-06-26finaledT07BU01401City permit recordBUILDINSTALL:RACKS AND REISSUE CofO IN BUSINESS NAMEC of o
2007-06-26T07OT01490City permit recordC-OF-OC OF O:WHOLESALEWithdrwn
2007-06-25T07AN00515City permit recordADDRNEWIssued
2007-02-09finaledT07BU00326City permit recordSPKLRAdd 5 fire sprinklersFinal
2005-05-11finaledT05BU01145City permit recordGRADINGGRADING:Final
2005-02-16finaledT05CM00693City permit recordAddition / alterationADDITION:WAREHOUSEC of o
2003-07-29T03CM03757City permit recordCOMBONEW:WAREHOUSEWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (8)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 8 records
DateRecordWhatStatus
2023-09-20CE-VIO0923-05648Code enforcement caseVegetationClosed - resolved
2021-05-21T21DV03020Code enforcement caseRefuseComplian
2021-05-19T21DV02951Code enforcement caseCode enforcement caseComplian
2020-01-08T20DV00150Code enforcement caseCode enforcement caseComplian
2015-04-14T15DV02889Code enforcement caseSignComplian
2013-05-09T13DV03175Code enforcement caseCode enforcement caseNoverify
2007-05-15T07DV04403Code enforcement caseVegetationInvalid
2005-05-18T05VL00441Code enforcement caseWork without permitReferred

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14024073E — 23 permits on file from 2003 to 2024 (4 combo, 3 addition / alteration, 2 fence / wall, 2 spklr) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.