1616 E Bantam Rd, Tucson — built 1974, with 47 permits on record. Review electrical, HVAC and remodel history with links to official records.
Electrical Property Screening Report · Manufactured home
1616 E Bantam Rd
A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.
Verify parcel data at official source ↗
Built 1974 — manufactured home · 47 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1616 E Bantam Rd (aztucsonelectricalsolutions.com/property/140212180/1616-e-bantam-rd-tucson-az-85706) · Public records last checked 2026-08-19
Public record indicators for electrical planning
- Parcel
- 140212180
- Year constructed
- 1974 (county record)
- Permitting authority
- Tucson
- Zoning
- MH-1
- Lot size
- 8.22 acres
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: the federal flood layer did not answer when this page was built. That is a lookup failure, not a statement about the property. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 140212180 ↗ · the City of Tucson ↗
Is it time to upgrade?
- Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
- Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
- Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system.
- Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Worth confirming
This reads as a manufactured or mobile home. The electrical questions are different from a stick-built house: the service and meter usually sit on a separate pedestal, and the feeder from that pedestal to the home is where undersizing and corrosion show up first.
- Worth confirming
Bonding and grounding are the common finding on older units — the frame must be bonded, and the neutral and ground have to stay separated downstream of the service disconnect at the pedestal.
- Routine
Adding an EV charger, a mini-split, or a casita usually means looking at the pedestal service and feeder capacity rather than the panel inside the home.
What to check at the panel
Everything above is read off public records. These are the things only someone standing at the panel can settle, and they take about a minute.
- The rating on the main breaker at the service pedestal, not the panel inside the home — the pedestal is the service.
- The condition of the feeder running from the pedestal to the home, and its rating. Undersizing and corrosion show up here first.
- Whether the frame is bonded, and whether neutral and ground are separated downstream of the pedestal disconnect. This is the most common finding on older units.
- Whether the water heater, dryer and range are gas or electric — no public record carries fuel type, and it is the single biggest variable in what the service can still take.
With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work.
The most recent permitted work on this parcel was in 2022. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2022. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 47 building permits for this parcel dated between 1998 and 2022. By category the work is mh (25), row (3) and residential building - one or two family (2). 24 of them carry a final inspection; the other 23 were issued, expired or are still open, which is not the same as work completed. There are 9 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Code enforcement cases (9): 2023 CE-VIO0123-01642 · 2022 T22DV05651 · 2016 T16DV04784 · 2014 T14DV06463 · 2014 T14DV01761 · 2013 T13DV05220 · 2007 T07DV06165 · 2006 T06DV02095 · 1999 T99VL02813
City permit record (47): 2022 T22MH00013 · 2022 T22CM00645 · 2019 T19RW06626 · 2019 T19CM07679 · 2019 T19RW05189 · 2019 T19MH00087 · 2018 T18CM06922 · 2016 T16RW02542 · 2016 T16CM06374 · 2016 T16CM06375 · 2015 T15EX01945 · 2015 T15TC01580 · 2010 T10PL01031 · 2010 T10BU00800 · 2009 T09BU01023 · 2008 T08OT02582 · 2008 T08BU00625 · 2007 T07CM03920 · 2007 T07CM03077 · 2004 T04MH00013 · 2003 T03MH00183 · 2003 T03MH00088 · 2003 T03MH00089 · 2003 T03MH00035 · 2003 T03MH00022 · 2003 T03MH00002 · 2002 T02MH00309 · 2002 T02PL01557 · 2002 T02MH00129 · 2002 T02MH00079 · and 17 older — search the parcel at the office below
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 140212180. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All mobile-home parks · Commercial property in 85706 · Commercial & industrial reports · Homes in 85706 · Permit data by neighborhood
Planning work at this home?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this report was built
This is a reading of public records for parcel 140212180 — 47 permits on file from 1998 to 2022 (25 mh, 5 combo, 3 row, 2 residential building - one or two family) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-19; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.