Electrical permit history — 194 W Valencia Rd

194 W Valencia Rd, Tucson — built 2002, with 13 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

194 W Valencia Rd

Built 2002 — 2000s commercial stock · last permitted panel/service work 2023 (finaled)

Parcel
138144580
Built
2002 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Store Front Commercial Bldg
Parcel size
0.88 acres
Building area
7,880 sq ft (assessor record)
Sewer
Connection on file (2002) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2023 permit was finalized; the permit description states “remove and replace existing 400amp disconnect with new 400amp disconnect”.

See the property

County aerial photograph centered on 194 W Valencia Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2023 (3 years ago). City inspection record: COT - LCEL - Electrical Final approved 2023-01-13. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0123-00396 — remove and replace existing 400amp disconnect with new 400amp disconnect
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2002-01-24$225,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-02-27 (TC-COM-0225-00399) — Replacing service disconnect..

Permit history (13)

Permit history for this parcel — 8 of 13 records
DateRecordWhatStatusValue
2025-02-27finaledTC-COM-0225-00399City permit recordCommercial BuildingReplacing service disconnect.Complete
2023-09-26finaledTR-UTL-0923-02582City permit recordRight-of-Way (ROW) - UtilityCOX TO BORE 219' TO INSTALL NEW CATV CONDUIT FOR SYSTEM TIE.Complete
2023-01-03finaledTC-COM-0123-00396City permit recordCommercial Buildingremove and replace existing 400amp disconnect with new 400amp disconnectComplete
2022-10-17T22CM07986City permit recordCommercial BuildingVOIDED WILL USE PERMIT TC-COM-0123-00396 (T22DV01196) We will replace vandalized 400amp disconnect with a new like for like 400amp disconnectVoid
2022-03-04finaledT22RW00780City permit recordROWLANE AND SIDEWALK CLOSURE FOR WELDING ON EXISTING POLE AND PATCHING APPROXIMATELY 12' OF SIDEWALK PANEL PER PAG SD 200. PLACEMENT OF SIDEWALK CLOSED AHEAD SIGNS AT NEAREST ADA RAMPS AND PLACEMENT OF SHOULDER WORK AHEAD SIGNS. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.Final
2020-07-07finaledT20RW03833City permit recordPool / spaBORE 105' AND TRENCH 27' TO PLACE INNERDUCT AND CONDUIT. PLACE 1-30X48 VAULT FOR TUC30_084 VALENCIA RD. IS UNDER MORATORIUM. MORATORIUM REQUIREMENTS SHALL BE MET. LANE CLOSURE ON TCP MAY HAVE TO SWITCH TO WEST BOUND DURING CONSTRUCTION. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 48-HOURS PRIOR TO START OF WORK FOR COORDINATION. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. MORATORIUM REQUIREMENTS WILL BE CONVEYED IN THE FIELD BY THE INSPECTOR. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS.Final
2012-03-21finaledT12OT00457City permit recordFence / wall1- C OF C DF SIGN / 1- ILLUM WALL SIGN / 20350Final
2002-04-19finaledT02OT00606City permit recordSIGNSIGN:3897Final
Show 5 older records
Permit history for this parcel — remaining 5 records
DateRecordWhatStatusValue
2002-02-22expired 2002-04-23T02EX00226City permit recordEXCAVEXCAV:INSTALL DRIVEWAY & CURBClosed
2001-10-12finaledT01CM05133City permit recordCOMBONEW STOREC of o
2001-07-12D01-0023City permit recordDevelopment PackageFAMILY DOLLAR/VALENCIAApproved
2001-06-27T01AN00585City permit recordADDRNEWIssued
2001-06-27T01OT00184City permit recordSITESITEVoid

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (12)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 12 records
DateRecordWhatStatus
2022-12-07CE-VIO1222-00853Code enforcement caseVegetationClosed - resolved
2022-02-15T22DV01196Code enforcement caseCode enforcement caseComplian
2022-01-11T22DV00205Code enforcement caseVegetationVoid
2022-01-11T22DV00215Code enforcement caseRefuseComplian
2021-08-04T21DV04948Code enforcement caseVegetationComplian
2021-02-23T21DV01005Code enforcement caseRefuseComplian
2019-10-16T19DV08202Code enforcement caseRefuseComplian
2015-07-13T15DV05047Code enforcement caseCode enforcement caseComplian
Show 4 older records
Code enforcement history for this parcel — remaining 4 records
DateRecordWhatStatus
2015-01-09T15DV00152Code enforcement caseRefuseComplian
2010-05-27finaledT10FR01049Code enforcement caseFireComplete
2008-11-03finaledT08FR04125Code enforcement caseFireComplete
2006-10-25finaledT06FR02695Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 138144580 — 13 permits on file from 2001 to 2025 (3 commercial building, 1 right-of-way (row) - utility, 1 row, 1 pool / spa) and 12 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.