Electrical permit history — 190 W Valencia Rd

190 W Valencia Rd, Tucson — built 1984, with 23 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

190 W Valencia Rd

Built 1984 — 1980s multifamily stock · last permitted panel/service work 2022 (finaled); a newer 2023 permit is issued

Parcel
13814457L
Built
1984 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Apartments 100+ Units 2 Story
Parcel size
2.39 acres
Building area
41,504 sq ft (assessor record)
Sewer
Connection on file (1983) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2022 permit was finalized; the permit description states “REPLACE METER SOCKET ASSEMBLY WITH MAIN BREAKER AND INSULATOR. NOTE Dan Santa Cruz considers this a service upgrade as there is no other category for it.” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 190 W Valencia Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentA newer 2023 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Replace Meter socket assembly, insulator and main breaker./ 'Like for Like' per applicant. 100 amp meter. Unit # 235.”. Last permitted 2022 (4 years ago). City inspection record: ELECTRIC - FINAL approved 2022-01-12. Contractor of record: Colt Construction Inc. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T22CM00016 — REPLACE METER SOCKET ASSEMBLY WITH MAIN BREAKER AND INSULATOR. NOTE Dan Santa Cruz considers this a service upgrade as there is no other category for it.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2020 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-08-13 (TC-COM-0826-01291) — Need an electrical clearance for TEP to connect service, as unit as not had electric utility service for more than 12months as it was vacant.

Permit history (23)

Permit history for this parcel — 8 of 23 records
DateRecordWhatStatusValue
2026-08-13TC-COM-0826-01291Commercial buildingTrade permitNeed an electrical clearance for TEP to connect service, as unit as not had electric utility service for more than 12months as it was vacantNeeds Resubmittal$100
2024-08-28applied 2024-06-28 · expired 2025-08-04TC-COM-0624-01272MultifamilyAddition / alterationbathroom exhaust fan caught damage. 4x4 sq for damage area20 sq ftInspections$5,000
2024-06-26expired 2024-12-23TC-COM-0624-01259City permit recordCommercial BuildingVoid - Duplicate/Same scope of work as existing application permit number TC-COM-1023-02316. Please resubmit under existing permit or withdraw existing permit before moving forward with a new application. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf exhaust fan caught fire small hole in roof . area to be replaced with like materialsVoid
2023-10-02expired 2024-09-04TC-COM-1023-02316City permit recordCommercial Buildingfire damage to exterior 2nd floor.Issued
2023-09-06expired 2024-03-24TC-COM-0923-02160City permit recordCommercial BuildingReplace Meter socket assembly, insulator and main breaker./ 'Like for Like' per applicant. 100 amp meter. Unit # 235.Issued
2023-03-30expired 2023-10-04TC-COM-0323-00925City permit recordCommercial Buildingmeter socket assembly and main breaker replacement for this one unitIssued
2022-12-27applied 2022-12-19 · expired 2023-07-16TC-COM-1222-00334Commercial buildingTrade permitReplace the main 100 breaker and Meter socket bussing for units 166 and 170 in a multi meter pack.Issued$1,400
2022-10-05finaledT22CM07660City permit recordCOMBOReplace Meter socket assembly with insulator and 100A 22K main breakerFinal
Show 15 older records
Permit history for this parcel — remaining 15 records
DateRecordWhatStatusValue
2022-07-22finaledT22CM05580City permit recordCOMBOreplace meter socket assembly, insulator and main breakerFinal
2022-01-03finaledT22CM00016City permit recordCOMBOREPLACE METER SOCKET ASSEMBLY WITH MAIN BREAKER AND INSULATOR. NOTE Dan Santa Cruz considers this a service upgrade as there is no other category for it.Final
2020-09-14finaledT20CM06281City permit recordCOMBOFIRE DAMAGE REPAIR (T20DV03350,3366)Final
2020-03-26finaledT20CM01918City permit recordCOMBOREPL GAS LINE FROM METER TO LAUNDRY ROOMFinal
2020-03-10finaledT20BU00109City permit recordFence / wallW - 7' FENCEFinal
2019-10-23finaledT19CM07822City permit recordCOMBOELECTRIC RECONNECTFinal
2019-02-28finaledT19BU00085City permit recordFence / wall7' IRON FENCEFinal
2016-08-29expired 2017-02-26T16BU01233City permit recordFence / wallFENCEExpired
2016-03-30finaledT16CM02356City permit recordCOMBOELECTRIC RECONNECTFinal
2015-12-17finaledT15CM08810City permit recordCOMBOREPL 100AMP MAIN BREAKERFinal
2013-11-15finaledT13CM06985City permit recordCOMBOCHANGE OUT 100 AMP MAIN BREAKER AND BUSS BARSFinal
2013-04-24finaledT13CM02438City permit recordCOMBOREPLACE 100 AMP MAINBREAKER AND POSSIBLE BUSSING (APA)Final
2012-08-03finaledT12CM04765City permit recordCOMBOREPLACE MAIN BREAKER UP TO 200AMPFinal
2012-07-11finaledT12CM04149City permit recordCOMBOREPLACE BREAKER UP TO 200AMP + REPLC METER SOCKET AND BUSSBARS (APA)Final
2001-01-26finaledT01PL00244City permit recordPLUMBGASLINE:REPAIR(APA)Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (25)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 25 records
DateRecordWhatStatus
2024-05-09closed 2024-05-10CE-VIO0524-01732Code enforcement caseFireClosed - Resolved
2024-05-09closed 2024-05-10CE-VIO0524-01727Code enforcement caseFireClosed - Resolved
2023-12-15CE-VIO1223-06910Code enforcement caseCode enforcement caseClosed - unfounded
2023-06-05CE-VIO0623-03902Code enforcement caseFireClosed - resolved
2020-05-14T20DV03350Code enforcement caseFireComplian
2020-05-14T20DV03364Code enforcement caseFireComplian
2020-05-14T20DV03366Code enforcement caseFireComplian
2020-05-14T20DV03367Code enforcement caseFireComplian
Show 17 older records
Code enforcement history for this parcel — remaining 17 records
DateRecordWhatStatus
2020-05-14T20DV03369Code enforcement caseFireComplian
2020-05-14T20DV03370Code enforcement caseFireComplian
2020-05-14T20DV03371Code enforcement caseFireComplian
2020-05-14T20DV03373Code enforcement caseFireComplian
2020-05-14T20DV03374Code enforcement caseFireComplian
2020-05-14T20DV03375Code enforcement caseFireComplian
2019-07-17T19DV05737Code enforcement caseCode enforcement caseComplian
2018-07-17T18DV04117Code enforcement caseCode enforcement caseVoid
2016-04-22T16DV02548Code enforcement caseElectricalComplian
2015-07-02T15DV04828Code enforcement caseCode enforcement caseComplian
2014-09-16T14DV07452Code enforcement caseCode enforcement caseComplian
2014-08-21T14DV06363Code enforcement caseCode enforcement caseComplian
2014-08-12T14DV06019Code enforcement caseCode enforcement caseComplian
2013-05-02T13DV02885Code enforcement caseCode enforcement caseNoverify
2012-06-11T12DV04863Code enforcement caseCode enforcement caseNoverify
2008-04-21T08DV03249Code enforcement caseCode enforcement caseComplian
2007-02-14T07DV01544Code enforcement caseCode enforcement caseCancel

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13814457L — 23 permits on file from 2001 to 2026 (12 combo, 4 commercial building, 3 fence / wall, 2 trade permit) and 25 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.