Electrical permit history — 6302 S 6th Av
6302 S 6th Av, Tucson — built 1998, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
6302 S 6th Av
Build year not published — permits on file from 1998 · HVAC 2014 (finaled)
Permanent link: Electrical permit history for 6302 S 6th Av (aztucsonelectricalsolutions.com/property/13812038b/6302-s-6th-av-tucson-az-85706) · Public records last checked 2026-08-17
- Parcel
- 13812038B
- Built
- 1998 (earliest permit on file)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Telecommunications Property
- Parcel size
- 2.03 acres
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 right-of-way (row) - utility permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalGetting onLast permitted 2014 (12 years ago). City inspection record: BUILDING - FINAL approved 2014-11-12. Contractor of record: BURKEL CONTRACTING INC , R W. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T14CM04056 — INSTALLATION OF CHILLER
- Fire alarm & life safetyCurrentLast permitted 2018 (8 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T18FC00271 — Add 3 Sprinkler heads - Relocate 1 Head
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2025-09-15 (TR-UTL-0925-01577) — w/o 3123360. 6300 s. 6th av. 15-13-12se. repair leaking main. bluestake 30'x30' area painted white on east side of property on asphalt and dirt. 8lf DR..
Permit history (19)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-09-15finaled | TR-UTL-0925-01577City permit record | Right-of-Way (ROW) - Utilityw/o 3123360. 6300 s. 6th av. 15-13-12se. repair leaking main. bluestake 30'x30' area painted white on east side of property on asphalt and dirt. 8lf DR. | Complete | |
| 2025-09-10finaled | TR-UTL-0925-01547City permit record | Right-of-Way (ROW) - Utilitywo#319580 6300 s 6th ave 15-13-12 se repair 4" fire protection valve painted out in white at the north east corner of the lot in dirt and asphalt 6lf/ar | Complete | |
| 2025-03-18finaled | TR-UTL-0325-00461City permit record | Right-of-Way (ROW) - Utilitywo#2997309 6300 S 6th Ave 15-13-12 se to replace valves and tee in intersection in asphalt 15lf/ar | Complete | |
| 2025-01-29 | TR-ROW-0125-00138City permit record | Right-of-Way (ROW)6th Ave Drexel to Valencia - Pave & Mill / Potholing 25-028 | Withdrawn | |
| 2023-09-11 | TR-UTL-0923-02477City permit record | Right-of-Way (ROW) - UtilityP.122865 (KAHNA) - ACCESS MH 6221, MH 14363, MH 15554B, MH 16414, MH 21721 & MH 16243, MH 19762 & 2 EX HH'S FOR SPLICING | Denied | |
| 2020-10-16finaled | T20RW05679City permit record | ROWCHANGING OUT (3) TEP POLES AT CIRCLED LOCATIONS. WO 6300305. | Final | |
| 2020-07-14finaled | T20RW04047City permit record | ROWCHANGING OUT (3) TEP POLES AT CIRCLED LOCATIONS. | Final | |
| 2018-04-03finaled | T18FC00271City permit record | FIRECONSAdd 3 Sprinkler heads - Relocate 1 Head | Final |
Show 11 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2017-10-02finaled | T17FO00829City permit record | FIREOPERTELECOMMUNICATIONS SWITCHING FACILITY | Final | |
| 2017-10-02finaled | T17FO00830City permit record | FIREOPERTELECOMMUNICATIONS SWITCHING FACILITY | Final | |
| 2015-08-31finaled | T15BU00993City permit record | TANKSUNDERGROUND STORAGE TANK REMOVAL | Final | |
| 2014-06-30finaled | T14CM04056City permit record | COMBOINSTALLATION OF CHILLER | L of c | |
| 2008-02-07finaled | T08BU00239City permit record | BUILDFIRE ALARM SYSTEM | Final | |
| 2007-12-17expired 2008-06-16 | T07BU02608City permit record | BUILDFIRE ALARM SYSTEM | Expired | |
| 2007-10-15finaled | T07CM04051City permit record | COMBOTI:CHILLER UPGRADE | Final | |
| 2000-05-31finaled | T00BU01631City permit record | SPKLRFIRE SPKR:ADD 2 | Final | |
| 1999-08-17expired 2000-04-17 | T99BU02242City permit record | SPKLRFIRE SPKR:ADD 6 | Closed | |
| 1998-11-17expired 1999-01-16 | T98EX01366City permit record | EXCAVEXCAV:TRENCH 275LF | Closed | |
| 1998-03-30finaled | T98CM01301City permit record | COMBOGENERATOR:ELECTRIC | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2009-05-14finaled | T09FR01699Code enforcement case | Fire | Complete |
| 2008-09-24 | T08FR03069Code enforcement case | Code enforcement case | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 13812038B — 19 permits on file from 1998 to 2025 (4 right-of-way (row) - utility, 3 combo, 2 row, 2 fireoper) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.