Built 1962 — 1960s commercial stock · last permitted panel/service work 2013 (finaled)
Permanent link: Electrical permit history for 6443 S 12th Av (aztucsonelectricalsolutions.com/property/13805045h/6443-s-12th-av-tucson-az-85706) · Public records last checked 2026-08-17
- Parcel
- 13805045H
- Built
- 1962 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Retail Strip Center
- Parcel size
- 0.57 acres
- Building area
- 4,200 sq ft (assessor record)
- Sewer
- Connection on file (2010) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2013 permit was finalized; the permit description states “UPGRADE ELECTRICAL SERVICE FROM 400 AMPS TO 800 AMPS.” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2013 (13 years ago). City inspection record: ELECTRIC - FINAL approved 2013-11-13. Contractor of record: BUCHANAN ELECTRIC INC ,. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T13CM05593 — UPGRADE ELECTRICAL SERVICE FROM 400 AMPS TO 800 AMPS.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2010 solar pv permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Solar equipment was permitted here in 2010 — the permit category covers PV, solar water heating and pool heating alike. If it was PV, there is an existing interconnection and the busbar already carries backfeed, which constrains what else can be added under the 120% rule; a thermal system carries no such constraint. Worth confirming which it is.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2006-01-27 | $780,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2024-04-26 (TS-PRM-0424-00181) — Fab & install LED illuminated channel letters flush to fascia.
Permit history (19)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-04-26expired 2024-10-23 | TS-PRM-0424-00181City permit record | Sign - PermanentFab & install LED illuminated channel letters flush to fascia | Expired | |
| 2020-03-24finaled | T20OT00275City permit record | Fence / wall2-ILLUM WALL SIGN | Final | |
| 2019-06-25finaled | T19RW03635City permit record | ROW10 LF REAR ASPHALT ALLEY TO REPAIR LEAKING MAIN - EMERGENCY | Final | |
| 2017-09-25 | T17CM07317City permit record | COMBOREMODEL BATHROOM | Withdrwn | |
| 2016-05-13finaled | T16EX01851City permit record | EXCAVFor COT Road Recovery Fiscal Year 2017 Rehabilitation Package 2, COT Proj No. U-2016-004 - Air Vacuum Excavation of 16 Utility Potholes 12"x12" in size along 12th Ave between Valencia Rd and Ajo Way | Final | |
| 2016-05-13 | T16TC01170City permit record | BARRICADFor COT Road Recovery Fiscal Year 2017 Rehabilitation Package 2, COT Proj No. U-2016-004 - Air Vacuum Excavation of 16 Utility Potholes 12"x12" in size along 12th Ave between Valencia Rd and Ajo Way | Expired | |
| 2015-11-20expired 2016-05-30 | T15OT01558City permit record | Fence / wall1 - ILLUM WALL SIGN | Sign-pc | |
| 2014-04-14expired 2015-04-11 | T14OT00461City permit record | Fence / wall2- IDENTICAL ILLUM WALL SIGNS ON THE E. & S. ELEVS | Expired |
Show 11 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2013-09-11finaled | T13CM05593City permit record | COMBOUPGRADE ELECTRICAL SERVICE FROM 400 AMPS TO 800 AMPS. | Final | |
| 2012-04-06expired 2012-10-06 | T12CM01648City permit record | COMBORECONNECT: ELECTRIC - RES | Expired | |
| 2010-11-05finaled | T10CM03125City permit record | Solar PVADD; 8 PANEL SOLAR HOT WATER HEATER | Final | |
| 2010-05-19finaled | T10OT01077City permit record | SIGN18368 | Final | |
| 2010-04-20finaled | T10CM01062City permit record | COMBOTI:FOOD SERVICE:TAKE OUT ONLY | C of o | |
| 2010-03-25 | T10OT00664City permit record | C-OF-OC OF O: RETAIL /FOOD SERVICES TAKE OUT ONLY | Withdrwn | |
| 2006-07-27finaled | T06OT01973City permit record | SIGN11559 | Final | |
| 2006-03-06finaled | T06OT00621City permit record | SIGN10752 | Final | |
| 2005-04-01expired 2005-10-23 | T05EL00636City permit record | ELECTELEC: RECONNECT OFFICE | Expired | |
| 2004-12-22finaled | T04OT02500City permit record | SIGNSIGN:8240 12TH AVE LAUNDRY | Final | |
| 2004-10-06finaled | T04CM04442City permit record | COMBOTI:12TH AVE LAUNDRY | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (7)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-01-08 | CE-VIO0125-00090Code enforcement case | Work without permit | Closed - resolved |
| 2015-06-15 | T15DV04431Code enforcement case | Work without permit | Complian |
| 2015-01-28 | T15DV00533Code enforcement case | Code enforcement case | Complian |
| 2014-10-20 | T14DV08725Code enforcement case | Sign | Complian |
| 2014-06-30 | T14DV04327Code enforcement case | Code enforcement case | Complian |
| 2010-11-19finaled | T10FR02427Code enforcement case | Fire | Complete |
| 2009-11-06finaled | T09FR03479Code enforcement case | Fire | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 13805045H — 19 permits on file from 2004 to 2024 (5 combo, 4 sign, 3 fence / wall, 1 sign - permanent) and 7 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.