Electrical permit history — 1840 W Valencia Rd

1840 W Valencia Rd, Tucson — built 2001, with 10 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1840 W Valencia Rd

Built 2001 — 2000s commercial stock · last permitted panel/service work 2024 (permitted, completion not confirmed) · HVAC 2018 (finaled)

Parcel
137339100
Built
2001 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Store Front Commercial Bldg
Parcel size
0.65 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2024 permit was issued; completion is not confirmed in the available record; the permit description states “REPLACE 200AMP PANEL LIKE FOR LIKE WAS DAMAGED”.

See the property

County aerial photograph centered on 1840 W Valencia Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2024 permit specifies this work (the permit description states “REPLACE 200AMP PANEL LIKE FOR LIKE WAS DAMAGED”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: COT - LCEL - Electrical Final approved 2024-04-18. TC-COM-0124-00022 — REPLACE 200AMP PANEL LIKE FOR LIKE WAS DAMAGED
  • Heating, cooling & mechanicalCurrentLast permitted 2018 (8 years ago). City inspection record: MECHANICAL - FINAL approved 2018-03-29. Contractor of record: LENNOX NATIONAL ACCOUNT SERVICES LLC. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T18CM01932 — repl 3 like for like hvac units
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2024-01-04 (TC-COM-0124-00022) — REPLACE 200AMP PANEL LIKE FOR LIKE WAS DAMAGED.

Permit history (10)

Permit history for this parcel — 8 of 10 records
DateRecordWhatStatusValue
2024-01-04expired 2024-10-15TC-COM-0124-00022City permit recordCommercial BuildingREPLACE 200AMP PANEL LIKE FOR LIKE WAS DAMAGEDIssued
2021-12-27expired 2023-03-19T21CM09881City permit recordPool / spaINTERIOR TENANT ALTERATION OF EXISTING TENANT SPACEIssued
2020-08-31finaledT20RW04832City permit recordROWTHIS JOB WILL PLACE, PULL AND SPLICE NEW FIBER IN EXISTING UTILITY CONDUIT FOR 6,060'. WORK WILL BE PERFORMED ON W VALENCIA WITH TWO LATERALS ON S MIDVALE PARK RD AND S OAK TREE DR FOR TUC40_014-LD. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 48-HOURS PRIOR TO START OF WORK FOR COORDINATION. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS.Final
2020-06-03finaledT20OT00403City permit recordFence / wall4 - illum wall signsFinal
2018-07-26finaledT18RW03279City permit recordROWStarting in front of 1825 W. Valencia Rd at Cox existing PED, Trench / Bore North 150' continue East 55' placing a 3x3x3 pothole for Split Y connect and New PED PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTAINED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. SEE EXPIRED PERMIT # T18RW02331Final
2018-05-21finaledT18RW02331City permit recordROWStarting in front of 1825 W. Valencia Rd at Cox existing PED, Trench / Bore North 150' continue East 55' placing a 3x3x3 pothole for Split Y connect and New PED PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTAINED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED.Final
2018-03-14finaledT18CM01932City permit recordCOMBOrepl 3 like for like hvac unitsL of c
2017-05-11expired 2017-11-07T17OT00498City permit recordFence / wall4-ILLUM WALL SIGNS, 1-CofC for DFExpired
Show 2 older records
Permit history for this parcel — remaining 2 records
DateRecordWhatStatusValue
2015-11-02expired 2016-05-16T15OT01480City permit recordFence / wall3 - ILLUM WALL SIGNS & 1-CofC on MONU SIGNExpired
2015-10-20finaledT15CM07254City permit recordCOMBOADD RECEPTACLES;COMMFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2015-06-29T15DV04713Code enforcement caseSignNoverify
2014-07-14T14DV04731Code enforcement caseSignComplian
2013-01-16T13DV00353Code enforcement caseCode enforcement caseComplian
2012-12-03T12DV10839Code enforcement caseGraffitiComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 137339100 — 10 permits on file from 2015 to 2024 (3 row, 3 fence / wall, 2 combo, 1 commercial building) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.