Electrical permit history — 1800 W Valencia Rd

1800 W Valencia Rd, Tucson — built 1998, with 57 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

1800 W Valencia Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1998 — 1990s commercial stock · HVAC 2023 (permitted, completion not confirmed)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 special events fire permit - vendor permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “Replacing 24 like for like HVAC package units on roof”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-COM-1123-02648 — Replacing 24 like for like HVAC package units on roof
  • Fire alarm & life safetyFinaled permit foundA newer 2023 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Minor adjustments to existing in rack sprinklers to accommodate new racking layout.”. Last permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00479 — FIRE ALARM UPGRADE
  • RoofPermitted — completion not confirmedA 2026 permit specifies this work (the permit description states “Main Roof: Leave the existing roofing system in place. Temporarily, by section, move over and stockpile the rock ballast, then install a new loose-laid TPO membrane with heat-welded seams. After each section of TPO installation, replace the rock ballast over the new membrane. The contractor’s canopy and garden center roofs are mechanically attached TPO systems (unlike the main ballasted roof) and currently have two layers of membrane. In these areas, both existing membrane layers will be removed and replaced with a new TPO membrane. The existing insulation may remain in place, provided it is confirmed to be dry.”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-COM-0726-01044 — Main Roof: Leave the existing roofing system in place. Temporarily, by section, move over and stockpile the rock ballast, then install a new loose-laid TPO membrane with heat-welded seams. After each section of TPO installation, replace the rock ballast over the new membrane. The contractor’s canopy and garden center roofs are mechanically attached TPO systems (unlike the main ballasted roof) and currently have two layers of membrane. In these areas, both existing membrane layers will be removed and replaced with a new TPO membrane. The existing insulation may remain in place, provided it is confirmed to be dry.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2017. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 208,703 sq ft (county building-footprint layer)
Usable for solar, planning estimate
≈ 146,100 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,610 kW — roughly 4,030 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 2,650,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$212,000–$345,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “I-10 and Valencia Rd”, is about 5.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13733909B
Year constructed
1998 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Warehhouse Type Store
Building area
190,597 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 57 building permits for this parcel dated between 1998 and 2026. By category the work is trade permit (13), special events fire permit - vendor (11), addition / alteration (7) and permanent sign (4). 32 of them carry a final inspection; the other 25 were issued, expired or are still open, which is not the same as work completed. There are 7 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13733909B. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85746 · Commercial & industrial reports · Homes in 85746 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on W VALENCIA RD hold 1,413 City permits on record, 357 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (64 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-0726-01044Commercial Addition/Alteration PermitIssued
2026TF-FOP-0626-00856Special Events Fire Permit - OrganizerIn Review
2026TF-FOP-0526-00621Special Events Fire Permit - VendorComplete
2025TF-FOP-0925-01268Special Events Fire Permit - VendorComplete
2025TP-PRE-0525-00104Pre-Application ConferenceComplete
2025TF-FOP-0525-00636Special Events Fire Permit - VendorComplete
2024TF-FOP-1024-01116Special Events Fire Permit - VendorComplete
2024CE-VIO1024-04023Code enforcement caseClosed - Resolved
2024TF-FOP-0424-00506Special Events Fire Permit - VendorComplete
2023TC-COM-1123-02648Commercial Trade PermitIssued
2023TF-FOP-0923-01506Special Events Fire Permit - VendorComplete
2023TF-FCP-0923-01106Fire Automatic Extinguishing System PermitExpired
2023TC-COM-0723-01859Commercial Trade PermitWithdrawn
2023recordRight-of-Way (ROW) Permit - UtilityComplete
2022T22FO00842Special Events Fire Permit - VendorComplete
2022T22CM07599Commercial Trade PermitWithdrawn
2022T22SA00266Zoning ComplianceComplete
2022T22CFW0045Special Events Fire Permit - VendorComplete
2022DP21-0189Development PackageComplete
2021T21FO00670Special Events Fire Permit - VendorComplete
2021T21FC00479Fire Alarm System PermitComplete
2021T21CM07277Commercial Trade PermitWithdrawn
2021S21-039 Land Split/Lot SplitComplete
2021T21PRE0088Pre-Application ConferenceCanceled
2020T20FO00518Special Events Fire Permit - VendorComplete
2020T20CM06318Commercial Trade PermitWithdrawn
2019T19FO00988Special Events Fire Permit - VendorComplete
2019T19OT00788Peddler PermitCanceled
2019T19PRE0118Pre-Application ConferenceCanceled
2018T18OT00735Peddler PermitCanceled
2018T18DV03711PEDDLERSCOMPLIAN
2017T17CM08072Commercial Trade PermitComplete
2017T17DV05561EMERGENCYCOMPLIAN
2014T14SA00145Zoning ComplianceComplete
2013T13SA00093Zoning ComplianceComplete
2013DP13-0028Development PackageExpired
2012T12DV10761MULTIPLE TYPESCOMPLIAN
2012T12DV05139WEEDSNOVERIFY
2009T09DV02504ENVIRONMENTALCOMPLIAN
2008T08CM03516Commercial Addition/Alteration PermitWithdrawn
2008T08DV01857PAINT DISTCANCEL
2008T08BU00425GradingWithdrawn
2007T07PL00734Residential Trade PermitComplete
2006T06EL01396Commercial Trade PermitCanceled
2005T05BA00211Stormwater BasinApproved
2004T04OT01208Permanent Sign PermitCanceled
2004T04BU00330Commercial Trade PermitComplete
2004T04OT00396Permanent Sign PermitComplete
2004T04OT00265Permanent Sign PermitComplete
2004T04BU00257Fire Automatic Extinguishing System PermitComplete
2004T03BU02375GradingCanceled
2003T03CM04380Commercial Addition/Alteration PermitComplete
2003T03CM03747Commercial Addition/Alteration PermitWithdrawn
2003T03BU01880Commercial DemolitionCanceled
2002T02EL02096Commercial Trade PermitCanceled
2002T02EL00316Commercial Trade PermitComplete
2001T01VL02073Permanent Sign PermitComplete
2001T01CM02163Commercial Addition/Alteration PermitCanceled
2000D00-0060Development PackageCanceled
2000T00ME01192Commercial Trade PermitComplete
1999T99EL02693Commercial Trade PermitCanceled
1998T98BU01616Fire Automatic Extinguishing System PermitComplete
1998T98CM02276Commercial Addition/Alteration PermitComplete
1998T98CM01042Commercial Addition/Alteration PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13733909B — 57 City permits on file from 1998 to 2026 and 7 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.