Electrical permit history — 5525 S Mission Rd

5525 S Mission Rd, Tucson — built 1988, with 56 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

5525 S Mission Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1988 — 1980s multifamily stock · 1 open code case · 56 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2020 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2020 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2001. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2014. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 110,729 sq ft (county building-footprint layer, 12 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 77,500 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 850 kW — roughly 2,130 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,400,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$112,000–$182,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 5.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13711428V
Year constructed
1988 (assessor record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 100+ Units 3 Or More Story
Building area
202,002 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 56 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (33), addition / alteration (16), zoning compliance (4) and right-of-way (row) permit - utility. 46 of them carry a final inspection; the other 10 were issued, expired or are still open, which is not the same as work completed. There are 25 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13711428V. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85746 · Commercial & industrial reports · Homes in 85746 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S MISSION RD hold 1,060 City permits on record, 147 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (81 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0926-03667FireReceived
2026TC-COM-0826-01227Commercial Trade PermitNeeds Resubmittal
2026TC-COM-0626-00928Commercial Trade PermitNeeds Resubmittal
2026TC-COM-0626-00926Commercial Trade PermitNeeds Resubmittal
2026recordRight-of-Way (ROW) Permit - UtilityFees Due
2023TC-COM-0523-01408Commercial Trade PermitIssued
2023TS-PRM-1122-00031Permanent Sign PermitComplete
2023TS-MSP0323-00007Master Sign ProgramComplete
2022T22SA00213Zoning ComplianceComplete
2021T21CM03237Commercial Addition/Alteration PermitExpired
2021T21DV01692EMERGENCYCOMPLIAN
2021T21DV01693EMERGENCYCOMPLIAN
2021T21DV01691EMERGENCYCOMPLIAN
2021T21DV00962EMERGENCYCOMPLIAN
2021T21DV00963EMERGENCYCOMPLIAN
2020T20SA00275Zoning ComplianceComplete
2020T19CM05928Commercial Addition/Alteration PermitComplete
2019T19DV08925OBSTR DEAD TREES AND SHRUBSNOVERIFY
2019T19CM03252Commercial Trade PermitCanceled
2018T18SA00557Zoning ComplianceComplete
2018T18DV07149RES: MINIMUM HOUSINGCANCEL
2018T18DV04831PROP MAINT MULTIPLE TYPESCOMPLIAN
2018T18DV03619MULTIPLE TYPESCOMPLIAN
2017T17SA00209Zoning ComplianceComplete
2016T16CM07784Commercial Addition/Alteration PermitComplete
2016T16DV04879EMERGENCYCOMPLIAN
2015T15DV06738RES: MINIMUM HOUSINGNOVERIFY
2014T14DV09003RES: MINIMUM HOUSINGNOVERIFY
2014T14DV06273RES: MINIMUM HOUSINGCOMPLIAN
2014T14CM02940Commercial Trade PermitComplete
2014T14CM02941Commercial Trade PermitComplete
2014T14CM02942Commercial Trade PermitComplete
2014T14CM02936Commercial Trade PermitComplete
2014T14CM02937Commercial Trade PermitComplete
2014T14CM02938Commercial Trade PermitComplete
2014T14CM02939Commercial Trade PermitComplete
2014T14CM02943Commercial Trade PermitComplete
2014T14CM02944Commercial Trade PermitComplete
2014T14CM02945Commercial Trade PermitComplete
2013T13CM07629Commercial Trade PermitComplete
2013T13DV08574COMMERCIAL ZONINGNOVERIFY
2013T13DV06987RES: MINIMUM HOUSINGCOMPLIAN
2013T13CM05338Commercial Trade PermitCanceled
2013T13DV05241RES: MINIMUM HOUSINGNOVERIFY
2013T13CM00316Commercial Trade PermitCanceled
2013T13CM00317Commercial Trade PermitComplete
2011T11DV08336MULTIPLE TYPESCOMPLIAN
2011T11DV07966RES: MINIMUM HOUSINGCOMPLIAN
2011T11DV05285ENVIRONMENTALCOMPLIAN
2010T10BU00178Commercial Addition/Alteration PermitComplete
2010T10BU00180Commercial Addition/Alteration PermitComplete
2010T10BU00184Commercial Addition/Alteration PermitComplete
2010T10BU00185Commercial Addition/Alteration PermitComplete
2010T10BU00186Commercial Addition/Alteration PermitComplete
2010T10BU00179Commercial Addition/Alteration PermitComplete
2010T10BU00181Commercial Addition/Alteration PermitComplete
2010T10BU00182Commercial Addition/Alteration PermitComplete
2010T10BU00183Commercial Addition/Alteration PermitComplete
2010T10BU00187Commercial Addition/Alteration PermitComplete
2010T10BU00188Commercial Addition/Alteration PermitComplete
2010T10DV00976ENVIRONMENTALCOMPLIAN
2009T09BU00992Commercial Trade PermitComplete
2009T09BU00993Commercial Trade PermitComplete
2009T09BU00994Commercial Trade PermitComplete
2009T09BU00995Commercial Trade PermitComplete
2009T09BU00996Commercial Trade PermitComplete
2009T09BU00997Commercial Trade PermitComplete
2009T09BU00998Commercial Trade PermitComplete
2009T09DV03160ENVIRONMENTALCOMPLIAN
2008T08CM04027Commercial Addition/Alteration PermitComplete
2008T08EL01666Commercial Trade PermitComplete
2008T08DV06657WEEDSNOVERIFY
2008T08DV05995REFUSECOMPLIAN
2008T08DV05635REFUSECOMPLIAN
2006T06EL02272Commercial Trade PermitComplete
2005T05BU03000Commercial Addition/Alteration PermitComplete
2001T01EL01951Commercial Trade PermitComplete
2001T01EL00464Commercial Trade PermitComplete
1998T98EL02061Commercial Trade PermitCanceled
1998T98EL02007Commercial Trade PermitComplete
1997T97PL01824Commercial Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13711428V — 56 City permits on file from 1997 to 2026 and 25 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.