Electrical permit history — 5515 S Calle Santa Cruz
5515 S Calle Santa Cruz
- Electrical service: no service or distribution permit on record, and no build year is published.
- Watch for: no build year is published, so the wiring era is unknown. A look at the panel settles it.
- Other work on record: pre-application conference permit 2025, zoning compliance permit 2019, trade permit 2015, and 1 more — see the records below.
From City of Tucson permits, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
No published build year for this parcel. Year built is only published for part of the county — most of it inside Tucson city limits — and this parcel isn't in that dataset. Tell us roughly when it was built and you'll get the same read.
Is it time to upgrade?
Can’t tell yet: no service permit is on record and no build year is published.
- Electrical service & distributionWorth checkingNo service or distribution permit on record, and no build year is published. Capacity and condition come from the nameplates and the panel schedule, not from this record. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalWorth checkingNo permit on record names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyWorth checkingNo permit on record names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofWorth checkingNo permit on record names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
What that usually means electrically
- Era-based check
A capacity and condition review is the usual starting point before any tenant improvement or added load.
- Routine
A trade permit was pulled in 2015. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 4.8 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 137055410 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 137055410
- Permitting authority
- Tucson
- Zoning
- C-3
- Property type
- Power Center
- Electrical service
- No service or distribution permit on record, and no build year is published.
Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2025. City records show the permit was finalized. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 6 building permits for this parcel dated between 2015 and 2025. Two development package permits, two zoning compliance permits, one pre-application conference permit and one trade permit. 4 of them carry a final inspection; the other 2 were issued, expired or are still open, which is not the same as work completed.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (6): 2025 TD-DEV-1225-00301 · 2025 TP-PRE-0825-00173 · 2022 TD-DEV-1222-00090 · 2019 T19SA00487 · 2019 T19SA00071 · 2015 T15BU00300
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 137055410.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85706 · Commercial & industrial reports · Homes in 85706 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 5515 S Calle Santa Cruz (aztucsonelectricalsolutions.com/property/137055410/5515-s-calle-santa-cruz-tucson-az-85706)
Electrical summary — 5515 S Calle Santa Cruz, Tucson, AZ 85706
Parcel 137055410Year built not publishedPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: no service or distribution permit on record, and no build year is published.
- Watch for: no build year is published, so the wiring era is unknown. A look at the panel settles it.
- Other work on record: pre-application conference permit 2025, zoning compliance permit 2019, trade permit 2015, and 1 more — see the records below.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Dec 2025 | TD-DEV-1225-00301 | Development package permit | Open |
| Aug 2025 | TP-PRE-0825-00173 | Pre-application conference permit | Final |
| Nov 2019 | T19SA00487 | Zoning compliance permit | Final |
| Feb 2019 | T19SA00071 | Zoning compliance permit | Final |
| Mar 2015 | T15BU00300 | Trade permit | Final |
Voided or withdrawn permit records: 1 (not listed).
Ask your inspector or engineer to check
- The main switchboard’s nameplate rating and the age and make of the distribution gear.
- Whether the arc-flash labels match the installed gear (NFPA 70E reviews them every five years).
Live report: https://www.aztucsonelectricalsolutions.com/property/137055410/5515-s-calle-santa-cruz-tucson-az-85706
How this property compares nearby
Properties on S CALLE SANTA CRUZ hold 629 City permits on record, 103 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 137055410 — 6 City permits on file from 2015 to 2025 — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The assessor’s building record, the sewer connection file and the flood map were also not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 22 Sep 2026 and compared against the City’s 13 Nov 2026 permit export, with no change for this parcel.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.