Electrical permit history — 1225 W Irvington Rd

1225 W Irvington Rd, Tucson — built 2001, with 60 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1225 W Irvington Rd

Built 2001 — 2000s commercial stock · HVAC 2021 (finaled); a newer 2022 permit is issued

Parcel
137055230
Built
2001 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Power Center
Parcel size
9.86 acres
Building area
129,680 sq ft (assessor record)
Sewer
Connection on file (2008, 2011) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1225 W Irvington Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentA newer 2022 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “HVAC Retrofit Project at the Target in Tucson”. Last permitted 2021 (5 years ago). City inspection record: MECHANICAL - FINAL approved 2021-05-24. Contractor of record: AES Mechanical Services Group, Inc.. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T21CM03040 — Remove and replace 1 packaged rooftop HVAC unit, like for like.
  • Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00407 — Replacing Fire Alarm System
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2022. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    Solar was permitted here in 2015. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2000-10-31$2,000,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-05-08 (TF-FOP-0526-00635) — TARGET #1316 - CFW retail sales.

Permit history (60)

Permit history for this parcel — 8 of 60 records
DateRecordWhatStatusValue
2026-05-08finaledTF-FOP-0526-00635City permit recordFire OperationalTARGET #1316 - CFW retail salesComplete
2025-12-31expired 2026-06-29TC-COM-1225-02354City permit recordCommercial BuildingJUST RECONNECT NO REPIPE. BEING DONE FOR SW GAS CLEARANCE ONLY PER MATHEW CARLTON EMERGENCY GAS RECONNECT NEEDED OCCUPIED TARGET DISTRIBUTION CENTER Repaired leak on existing gas line no fittings replaced. Tightened unionInspections
2025-12-10finaledTF-FOP-1225-01608City permit recordFire OperationalTarget #1316 - CFW retail salesComplete
2025-07-01expired 2025-10-12TR-ROW-0725-00877City permit recordRight-of-Way (ROW)Prop 411 Calle Santa Cruz Pavement Rehabilitation & Sidewalk (IRVINGTON RD TO VALENCIA RD) COT JOB NO. U-2025-002 Times: 8PM - 5AM and 6AM to 6PM Contact-Armando Valero***Inspections
2025-05-08finaledTF-FOP-0525-00651City permit recordFire OperationalTARGET #1316 - CFW retail salesComplete
2024-12-02finaledTF-FOP-1224-01417City permit recordFire OperationalTARGET 1316 - CFW RETAIL SALESComplete
2024-04-29finaledTF-FOP-0424-00524City permit recordFire OperationalIndoor retail sales - CFW - special events vendorComplete
2023-12-07finaledTF-FOP-1223-01899City permit recordFire OperationalTarget- CFW INDOOR RETAIL SALEComplete

52 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (3)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 3 of 3 records
DateRecordWhatStatus
2008-10-17finaledT08FR03795Code enforcement caseCode enforcement caseComplete
2008-02-12finaledT08FR00417Code enforcement caseCode enforcement caseComplete
2004-11-18finaledT04FR00649Code enforcement caseFireComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 137055230 — 60 permits on file from 2006 to 2026 (24 firewrks, 9 combo, 8 fire operational, 3 commercial building) and 3 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.