Electrical permit history — 3700 S Calle Polar

3700 S Calle Polar, Tucson — built 2005, with 39 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

3700 S Calle Polar

Built 2005 — 2000s multifamily stock · last permitted panel/service work 2023 (permitted, completion not confirmed)

Parcel
136254120
Built
2005 (assessor record)
Jurisdiction
Tucson
Zoning
RX-1
Assessor use
Apartments 25 - 99 Units 1 Story
Parcel size
8.62 acres
Building area
30,346 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
D — flood hazard undetermined (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2023 permit was issued; completion is not confirmed in the available record; the permit description states “like for like panel replacement... 200 amp to 200 amp and has an underground feed”.

See the property

County aerial photograph centered on 3700 S Calle Polar, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “like for like panel replacement... 200 amp to 200 amp and has an underground feed”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: COT - LCEL - Electrical Final approved 2023-11-14. TC-COM-0923-02268 — like for like panel replacement... 200 amp to 200 amp and has an underground feed
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2026 permit for the same system is recorded as “Inspections” — The work was permitted, but final completion is not confirmed. The permit description states “Replacement of existing fire alarm system with new.”. Last permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1025-00935 — EXPEDITE - INSTALLATION OF (1) FIRE SPRINKLER MONITORING SYSTEM.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-04-29 (TC-COM-0426-00632) — Repipe water system in aqua pex.

Permit history (39)

Permit history for this parcel — 8 of 39 records
DateRecordWhatStatusValue
2026-04-29expires 2026-11-16TC-COM-0426-00632City permit recordCommercial BuildingRepipe water system in aqua pexInspections
2026-04-28finaledTC-RES-0426-02181City permit recordFence / wallScope of work: *WATER* Tie onto hot and cold 3/4 copper line inside the existing water heater closet and run new 1/2 insulated hot and cold type L copper lines to the exterior and wrap around to the front porch mounted along the wall with uni strut. New lines will serve a washing machine. *50feet 1/2" cold (new) *50 feet 1/2" hot (new) *DRAIN* For the drain there will be a 1/3 hp ejector pump system that will eject in 1 1/2 PVC up the wall and to the roof and over to the nearest stack on roof. *20 feet 1.1/2 schedule 40 pressure pipe and fittings (new)Complete
2026-04-28finaledTF-FOP-0426-00558City permit recordFire OperationalEsperanza En Escalante Sober Living Facility w/ 7 residents and a live in manager. With a total of 8 people in the facility.Complete
2026-03-09expired 2026-05-22TR-UTL-0326-00484City permit recordRight-of-Way (ROW) - UtilityWO T175438. TEP will remove 3 poles from ROW with no sidewalk impact.Inspections
2026-02-26TC-COM-0226-00280City permit recordCommercial BuildingVOID - DUPLICATE PERMIT; PLEASE CONTINUE WITH EXISTING PERMIT TC-COM-1025-01998 Repipe water systemVoid
2026-02-24expires 2026-09-16TF-FCP-0226-00119City permit recordFire ConstructionReplacement of existing fire alarm system with new.Inspections
2025-10-31finaledTC-COM-1025-01998City permit recordCommercial Building** whole home repipe **Complete
2025-10-29finaledTF-FCP-1025-00935City permit recordFire ConstructionEXPEDITE - INSTALLATION OF (1) FIRE SPRINKLER MONITORING SYSTEM.Complete
Show 31 older records
Permit history for this parcel — remaining 31 records
DateRecordWhatStatusValue
2025-10-28TC-RES-1025-05261City permit recordTrade permitVOID: – Wrong Permit Type. The scope of work and building type require that this request be submitted under a Commercial Trade Permit. This permit will be voided. For questions: Building_Official@tucsonaz.gov ** whole home repipe **Void
2025-09-04finaledTF-FCP-0925-00707City permit recordFire ConstructionEXPEDITE - Installation of (2) fire sprinkler monitoring systems.Complete
2025-09-04finaledTF-FCP-0925-00708City permit recordFire ConstructionEXPEDITE - Installation of fire sprinkler monitoring system.Complete
2025-06-06finaledTF-FCP-0625-00460City permit recordFire Constructioninstall new wet-type fire sprinkler system in existing duplex.Complete
2025-05-23finaledTF-FCP-0525-00410City permit recordFire ConstructionRetro fit two dwellings with new wet type fire sprinkler systems, to include connecting rise to existing privite fire loop. Unit #2 is a duplex of approximately 1,400 square feet fed by a single riser. Unit #5 is a 5 bedroom home of approximately 2,180 square feet fed by a single riser.Complete
2025-05-22TC-RES-0525-02688City permit recordPool / spaVOID: Wrong permit type. Please apply for the appropriate Fire Permit. For more information: https://www.tucsonaz.gov/files/sharedassets/public/v/1/fire/tdc_customer_self_service_user_guide.pdf Install a new wet type fire sprinkler system per NFPA 13D in two dwellings. Dwelling Unit #2 is a duplex home of approximately 2,180 square feet supplied by a single riser. Dwelling #5 is a home with 5 bedrooms of approximately 1,400 square feet, supplied by a single independent fire rise fed from an existing privite fire pool.Void
2025-01-21finaledTR-UTL-0125-00127City permit recordRight-of-Way (ROW) - UtilityCox to aerial overlash 4,620', trench 23' and bore 123' to install conduit and place vaulted ped for system tie.Complete
2025-01-21finaledTR-UTL-0125-00128City permit recordRight-of-Way (ROW) - UtilityWO T26204. TEP TO REPLACE 11 POLES & 7 ANCHORS (DIG 1-4’ & 17-2’ HOLES IN DIRT). REMOVE 1 POLE & 1 ANCHOR. INSTALL 1,940' OF OVERHEAD WIRE. Permit update 4/30/2025: Renewed for 90 days.Complete
2024-07-10finaledTZ-CMP-0724-00087City permit recordZoning Verification LetterI am requesting zoning verification (what is the property zoned, can the property be rebuilt as is if destroyed, is the property legally conforming/legally non-conforming.) *Please confirm any zoning violations or maps available*Complete
2024-05-15TR-ROW-0524-00586City permit recordRight-of-Way (ROW)This permit will be for bike path maintenance. The work consists of closing 1 mile long segments of the Aviation Greenway to seal coat and protect the existing asphalt.Void
2024-01-02expired 2024-06-30TC-COM-0124-00007City permit recordCommercial BuildingVOIDED DUPLICATE PERMIT like for like change out panel 200 amps to 200 amps NOTE: although i am applying for unit TEP has this as unit 5, somehow this got swaped however this will be inspected either wayVoid
2023-12-29expired 2024-06-26TC-COM-1223-02961City permit recordCommercial Buildinglike for like panel with underground feed note: the meter actually indicates that its actually unit 5 to TEP so ive been told to just apply as unit 4 because 5 is marked as already done but its actually not doneVoid
2023-12-28expired 2024-06-25TC-COM-1223-02955City permit recordCommercial BuildingVOIDED DUPLICATE PERMIT like for like panel 200 amp to 200 amp and it has an underground feedVoid
2023-09-25expired 2024-05-12TC-COM-0923-02268City permit recordCommercial Buildinglike for like panel replacement... 200 amp to 200 amp and has an underground feedIssued
2023-09-25expired 2024-06-08TC-COM-0923-02269City permit recordCommercial Buildinglike for like panel replacement... 200 amp to 200 amp and has an underground feedIssued
2023-09-25expired 2024-07-03TC-COM-0923-02270City permit recordCommercial Buildinglike for like panel replacement... 200 amp to 200 amp and has an underground feedIssued
2023-09-21expired 2024-03-19TC-RES-0923-08216City permit recordResidential Building - One or Two FamilyVOID: SUBMIT UNDER CORRECT PERMIT "Commercial trade". Its like for like panel replacement from 200 Amp to a 200 Amp and the main feed is through underground.Void
2023-09-21expired 2024-03-19TC-RES-0923-08217City permit recordResidential Building - One or Two FamilyVOID: SUBMIT UNDER CORRECT PERMIT "Commercial trade". like for like panel... replacing existing 200amp to 200amp panel with an underground main feedVoid
2023-09-21expired 2024-03-19TC-RES-0923-08219City permit recordResidential Building - One or Two FamilyVOID: SUBMIT UNDER CORRECT PERMIT "Commercial trade". like for like panel... replacing existing 200amp to 200amp panel with an underground main feedVoid
2023-09-18expired 2024-03-16TC-RES-0923-08114City permit recordTrade permit* VOID: YL-Unable to process, wrong permit type. Submit a new application under Commercial Trade Permit. This permit will be voided as it is not the correct permit type. Please note that each unit/location requires it's own individual permit.* -3 locations on same community... All three are like for like panels... Replacing existing 200 Amp panel with 200 Amp serviceVoid
2023-09-01expired 2024-04-15TC-RES-0923-07731City permit recordResidential Building - One or Two FamilyPanel upgrade to a 200 amp... it currently has a 200 amp panel... its a like for like replacement and its through an underground feedIssued
2023-06-30expired 2024-02-21TC-COM-0623-01622City permit recordCommercial BuildingPanel replacement/ 200 amps all in one 'Like for Like' per applicant. Unit #9Issued
2023-06-29expired 2023-12-26TC-RES-0623-06219City permit recordTrade permitVOIDED NEED TO SUBMIT A COMMERCIAL TRADE PERMIT AND INCLUDE A PLAN Panel replacement to 200 ampVoid
2023-06-14expired 2024-01-24TC-RES-0623-05925City permit recordResidential Building - One or Two FamilyPanel replacement to 200ampExpired
2020-05-28expired 2021-04-05T20CM03246City permit recordCommercial Building30'x40' shade structure with an 11' entrExpired
2018-11-13finaledDP18-0277City permit recordDevelopment PackageSITE/GRADING/SWPPP - ESPERANZA EN ESCALANTE, buildings 1-18 - PHASE II. Residential care services coComplete
2017-09-20expired 2018-03-19DP17-0231City permit recordDevelopment PackageSHADE CANOPYIssued
2016-04-19DP16-0069City permit recordDevelopment PackageSITEApproved
2015-10-27finaledDP15-0188City permit recordDevelopment PackageSITE/ GRADING -10 NEW VETERANS MULTI HOUSING BUILDINGS Originally approved 3/23/2016 (17 pages)Complete
2012-11-08finaledDP12-0207City permit recordDevelopment PackageESPERANZA EN ESCALANTEComplete
2006-01-10D06-0002City permit recordDevelopment PackageESPERANZA EL ESCALANTEApproved

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 136254120 — 39 permits on file from 2006 to 2026 (11 commercial building, 6 fire construction, 6 development package, 5 residential building - one or two family) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.