Electrical permit history — 6502 E Golf Links Rd
6502 E Golf Links Rd, Tucson — built 1983, with 40 permits on record. Review electrical, HVAC and remodel history with links to official records.
Electrical Property Screening Report · Multifamily property
6502 E Golf Links Rd
A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.
Verify parcel data at official source ↗
Built 1983 — 1980s multifamily stock · last permitted panel/service work 2016 (finaled)
Permanent link: Electrical permit history for 6502 E Golf Links Rd (aztucsonelectricalsolutions.com/property/13625271h/6502-e-golf-links-rd-tucson-az-85730) · Public records last checked 2026-08-20
Is it time to upgrade?
- Electrical service & distributionFinaled permit foundLast permitted 2016 (10 years ago). City inspection record: ELECTRIC - FINAL approved 2016-08-02. Contractor of record: BERT S ELECTRIC AND PLUMBING CO *APA*. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T16CM05681 — REPAIR/REPLACE METER SOCKET, BUSSING AND MAIN 100 AMP BREAKER (APA)
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 right-of-way (row) permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
A finaled 2016 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2006. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: FEMA flood zone X — minimal flood hazard, not a Special Flood Hazard Area. FIRM panel 04019C2303L, effective 2011-06-16. Open this property on FEMA’s official flood map ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 13625271H ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 13625271H
- Year constructed
- 1983 (county record)
- Permitting authority
- Tucson
- Zoning
- O-3
- Property type
- Apartments 100+ Units 2 Story
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Service on record
- City records show the 2016 permit was finalized; the permit description states “REPAIR/REPLACE METER SOCKET, BUSSING AND MAIN 100 AMP BREAKER (APA)”.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 40 building permits for this parcel dated between 1999 and 2026. By category the work is elect (10), commercial building (4) and right-of-way (row). 32 of them carry a final inspection; the other 8 were issued, expired or are still open, which is not the same as work completed. There are 19 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (40): 2026 TR-ROW-0526-00538 · 2025 TC-COM-1125-02107 · 2025 TR-UTL-1125-01968 · 2025 TC-COM-0625-01135 · 2024 TC-COM-0824-01618 · 2023 TC-COM-1023-02352 · 2022 T22CM03515 · 2022 T22CM00399 · 2021 T21CM02757 · 2018 T18RW04058 · 2017 T17CM02164 · 2016 T16CM05681 · 2015 T15CM07433 · 2015 T15CM05996 · 2014 T14CM05740 · 2014 T14CM02315 · 2014 T14CM01918 · 2014 T14CM01919 · 2013 T13CM05945 · 2013 T13CM05108 · 2013 T13CM03922 · 2013 T13CM01128 · 2013 T13CM00108 · 2012 T12CM07125 · 2012 T12CM06477 · 2012 T12CM04679 · 2012 T12CM04174 · 2012 T12EL00367 · 2012 T12EL00221 · 2011 T11EL02994 · and 10 older — search the parcel at the office below
Code enforcement cases (19): 2021 T21DV00959 · 2021 T21DV00960 · 2021 T21DV00961 · 2017 T17DV03466 · 2016 T16DV05231 · 2016 T16DV02858 · 2015 T15DV09472 · 2015 T15DV05296 · 2011 T11DV07303 · 2008 T08DV06685 · 2007 T07DV10952 · 2007 T07DV08573 · 2007 T07DV04663 · 2007 T07DV01850 · 2006 T06DV01272 · 2003 T03VL00583 · 2002 T02VL01478 · 2001 T01VL00484 · 1999 T99VL00112
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13625271H. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All multifamily property · Commercial property in 85730 · Commercial & industrial reports · Homes in 85730 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this report was built
This is a reading of public records for parcel 13625271H — 40 permits on file from 1999 to 2026 (20 combo, 10 elect, 4 commercial building, 1 right-of-way (row)) and 19 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-20; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.