Electrical permit history — 2699 S Pantano Rd

2699 S Pantano Rd, Tucson — built 1998, with 16 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2699 S Pantano Rd

Built 1998 — 1990s commercial stock · 16 permits on record; no permitted panel/service or HVAC work among them

Parcel
13615383A
Built
1998 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Auto Repair Garage Autos/Light Trucks
Parcel size
0.98 acres
Building area
2,673 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 2699 S Pantano Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2019-11-25$220,000Warranty Deed
2015-05-20$314,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-04-26 (TC-UTL-0425-00030) — AT&T equipment upgrade on existing Sooner wireless communication facility. AT&T is currently on Sooner Tower and would like to swap out its older Nokia equipment for upgraded Ericsson equipment to increase wireless reception in the area. The upgrade will not increase tower height, will not increase ground footprint or lease area, and will maintain current structure stealthing. Exact SOW is as follows: CHANGES ON THE EXISTING MONOPALM: · REMOVE (6) EXISTING ANTENNAS. · REMOVE ALL EXISTING NOKIA RADIOS. · REMOVE EXISTING TMAS · REMOVE EXISTING ANTENNA MOUNT · INSTALL NEW MSFAA PINCH RING · INSTALL NEW VFA6-HD ANTENNA MOUNT · INSTALL NEW 840-370966K ANTENNA ON P1 A/B/C · INSTALL NEW AIR6419 B77D+AIR6419 B77G STACKED ANTENNA ON P2 A/B/C · INSTALL NEW 840-370799K ANTENNA ON P3 A/B/C · INSTALL NEW 4490 B5/B12A & 4415 B30 RADIOS ON P1 A/B/C · INSTALL NEW 4478 B14 AND 4890 B25/B66 RADIOS ON P3 A/B/C · REUSE EXISTING DC AND FIBER TRUNKS. · INSTALL (1) NEW 24 PAIR FIBER · INSTALL (2) NEW 6AWG POWER TRUNK · INSTALL (1) NEW DC9-48-60-24-8C-EV (SQUID) CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · REMOVE ALL (E) NOKIA BBUS · INSTALL E// BBU'S (BBU INFORMATION TO BE FINALIZED PRIOR TO CONSTRUCTION) · INSTALL (1) SAU, (1) XMU, (2) 6651 & (1) 6610 IN NEW FLX42 PURCELL CABINET · INSTALL (1) NEW DC12-48-60-0-25E (OUTDOOR).

Permit history (16)

Permit history for this parcel — 8 of 16 records
DateRecordWhatStatusValue
2025-04-26finaledTC-UTL-0425-00030City permit recordUtilitiesAT&T equipment upgrade on existing Sooner wireless communication facility. AT&T is currently on Sooner Tower and would like to swap out its older Nokia equipment for upgraded Ericsson equipment to increase wireless reception in the area. The upgrade will not increase tower height, will not increase ground footprint or lease area, and will maintain current structure stealthing. Exact SOW is as follows: CHANGES ON THE EXISTING MONOPALM: · REMOVE (6) EXISTING ANTENNAS. · REMOVE ALL EXISTING NOKIA RADIOS. · REMOVE EXISTING TMAS · REMOVE EXISTING ANTENNA MOUNT · INSTALL NEW MSFAA PINCH RING · INSTALL NEW VFA6-HD ANTENNA MOUNT · INSTALL NEW 840-370966K ANTENNA ON P1 A/B/C · INSTALL NEW AIR6419 B77D+AIR6419 B77G STACKED ANTENNA ON P2 A/B/C · INSTALL NEW 840-370799K ANTENNA ON P3 A/B/C · INSTALL NEW 4490 B5/B12A & 4415 B30 RADIOS ON P1 A/B/C · INSTALL NEW 4478 B14 AND 4890 B25/B66 RADIOS ON P3 A/B/C · REUSE EXISTING DC AND FIBER TRUNKS. · INSTALL (1) NEW 24 PAIR FIBER · INSTALL (2) NEW 6AWG POWER TRUNK · INSTALL (1) NEW DC9-48-60-24-8C-EV (SQUID) CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: · REMOVE ALL (E) NOKIA BBUS · INSTALL E// BBU'S (BBU INFORMATION TO BE FINALIZED PRIOR TO CONSTRUCTION) · INSTALL (1) SAU, (1) XMU, (2) 6651 & (1) 6610 IN NEW FLX42 PURCELL CABINET · INSTALL (1) NEW DC12-48-60-0-25E (OUTDOOR)Inspections complete
2024-11-14expired 2025-03-02TR-UTL-1124-02156City permit recordRight-of-Way (ROW) - UtilityWO T125595. TEP will be removing 8 poles (89,88,185,21, 20,18,213,17), in the ROW 3'x3' holes 12' deep with be removed and backfilled. Will impact sidewalk. Locations are starting on Escalante along the East side of Pantano to Golf Links. 1 of 3.Inspections
2023-11-15finaledTR-UTL-1123-02923City permit recordRight-of-Way (ROW) - UtilityPlace aerial fiber over lash on E Golf Links Rd from S Marc Dr to S Pantano Rd. Place 4 hand holes over existing conduit stub ups on S Pantano Rd from E Golf Links Rd to E Escalante Rd. Pull fiber. This is part of the TEP Joint relocate project. Update 5/21/2024 - Request for 30 day extension as of 5/17/2024Complete
2023-11-07TR-ROW-1123-01332City permit recordRight-of-Way (ROW)Place 4 hand holes over existing Conduit stubs, Place aerial and buried fiber in conduit associated with TEP joint relocates on S Pantano Rd from E Golf Links Rd to E Escalante Rd for Teleport Communications America, LLC .Withdrawn
2023-09-20finaledTR-UTL-0923-02543City permit recordRight-of-Way (ROW) - Utility323020 Site 3 - Install Approximately 456 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. EMC will Rehabilitate the bench on MH's 8372-16 and MH 8372-12Complete
2022-07-06expired 2023-02-22T22CM05082City permit recordCommercial BuildingTHIS PROJECT WILL BE COMPRISED OF:CHANGES ON THE EXISTING MONOPALM:· POSITION 1- REMOVE (1) ANTENNIssued
2022-03-02expired 2023-11-15T22CM01516City permit recordCommercial BuildingModification to an Existing Monopalm by adding (3) antennas, (6) radio heads, (1) Raycap, (1) hybridIssued
2019-10-22finaledT19FO00909City permit recordFIREOPERGARNER AUTOMOTIVE REPAIRFinal
Show 8 older records
Permit history for this parcel — remaining 8 records
DateRecordWhatStatusValue
2019-01-18finaledT19CM00362City permit recordCOMBOCELL TOWER ANTENNAFinal
2016-03-21finaledT16EX00867City permit recordEXCAVACCESS MANHOLE # 17327 AND BORE 240' OF CABLE AND REPLACE 1248 PED WITH A CHARLES PED. WORK ORDER # N.049217Final
2016-03-21finaledT16TC00699City permit recordBARRICADACCESS MANHOLE # 17327 AND BORE 240' OF CABLE AND REPLACE 1248 PED WITH A CHARLES PED. WORK ORDER # N.049217Final
2016-03-04finaledT16CM01679City permit recordCOMBOCELL TOWERFinal
2012-04-23finaledT12CM02131City permit recordCOMBOANTENNA REPLACEMENT - FAN PALM COMMUNICATION TOWERFinal
2011-07-19expired 2011-09-17T11EX00361City permit recordEXCAVTRENCHING +/- TO PLACE TIME WARNER FACILITIES ALONG PANTANO RD TRENCH WILL BE FROM BASE OF POLE AT SW COR. OF PROPERTY TO PROJECT PROPERTYClosed
2008-11-25finaledT08CM03769City permit recordCOMBOINSTALLATION OF ANTENNASFinal
1998-05-19expired 1998-07-18T98EX00592City permit recordEXCAVEXCAV:APRON:30 FT & 5LF FIRE LINEClosed

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (5)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 5 of 5 records
DateRecordWhatStatus
2019-01-23T19DV00399Code enforcement caseVegetationComplian
2013-09-24T13DV07209Code enforcement caseGraffitiComplian
2011-04-20finaledT11FR00869Code enforcement caseCode enforcement caseComplete
2011-03-30finaledT11FR00749Code enforcement caseCode enforcement caseComplete
2000-09-27T00VL01340Code enforcement caseCode enforcement caseClosed

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13615383A — 16 permits on file from 1998 to 2025 (4 combo, 3 right-of-way (row) - utility, 3 excav, 2 commercial building) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.