Electrical permit history — 8050 E Lakeside Pw
8050 E Lakeside Pw, Tucson — built 2005, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
8050 E Lakeside Pw
Built 2005 — 2000s commercial stock · 24 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 8050 E Lakeside Pw (aztucsonelectricalsolutions.com/property/13615040b/8050-e-lakeside-pw-tucson-az-85730) · Public records last checked 2026-08-17
- Parcel
- 13615040B
- Built
- 2005 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Medical Clinic No Pharmacy
- Parcel size
- 0.87 acres
- Sewer
- Connection on file (2006, 2013) (county sewer connection records)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00146 — *** No Plans *** Relocate 6 pendant fire sprinklers.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Most recent permit on record for this parcel: 2026-08-04 (TF-FOP-0826-01030) — VOID - Duplicate Permit#TF-FOP-0826-01028 - Outpatient clinic.
Permit history (24)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-08-04 | TF-FOP-0826-01030City permit record | Fire OperationalVOID - Duplicate Permit#TF-FOP-0826-01028 - Outpatient clinic | Void | |
| 2026-08-03 | TF-FOP-0826-01028City permit record | Fire OperationalOutpatient clinic | Fees paid | |
| 2025-06-17 | TF-FOP-0625-00873City permit record | Fire OperationalVOID - Duplicate permit - Annual for licensed healthcare facility. | Void | |
| 2025-06-02finaled | TF-FOP-0625-00803City permit record | Fire Operationaloutpatient clinic | Complete | |
| 2024-06-17finaled | TF-FOP-0624-00718City permit record | Fire OperationalCOPE Community Outpatient | Complete | |
| 2024-03-13finaled | TR-UTL-0324-00494City permit record | Right-of-Way (ROW) - UtilityPRJ267058-1 Cox to pull coax cable through 220' of existing conduit for CATV Service Drop | Complete | |
| 2023-06-21finaled | TF-FOP-0623-01178City permit record | Fire OperationalCope Community Services | Complete | |
| 2022-06-08finaled | T22FO00520City permit record | FIREOPERCOPE COMMUNITY SERVICES INC - LAKESIDE CLINIC (OUTPATIENT) | Final |
Show 16 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2021-02-24finaled | T21FC00146City permit record | FIRECONS*** No Plans *** Relocate 6 pendant fire sprinklers. | Final | |
| 2020-12-29finaled | T20CM09246City permit record | COMBOTI: GENOA HEALTH PHARMACY | L of c | |
| 2017-08-17finaled | T17RW03689City permit record | ROWStarting on the North Side of E. Lakeside PKWY North Of the ally at Cox PED, pull through Existing Conduit Going West under sidewalk 10' Then South 5' Placing a 3x3x3 Pothole with a Y intercept on the Edge of Roadway, continue South Trench/bore 220' Placing another 3x3x3 Pothole then Continuing Trench/Bore East 20' Under Sidewalk, Placing a New Cox PED, Continuing To out of Row | Final | |
| 2014-03-19finaled | T14CM01545City permit record | COMBOINSTALL PUSH PIER TO COMM | L of c | |
| 2014-03-17finaled | T14OT00310City permit record | Fence / wall2- PLASTIC WALL SIGNS | Final | |
| 2014-01-14finaled | T14BU00035City permit record | SPKLRRELOCATE 10/27 NEW SPRINKLERS | Final | |
| 2014-01-14 | T14CM00242City permit record | COMBO27 NEW/ 10 RELOCATE SPRINKLERS | Withdrwn | |
| 2013-11-07finaled | DP13-0222City permit record | Development PackageSITE | Complete | |
| 2013-11-06expired 2014-09-22 | T13CM06788City permit record | Addition / alterationADDITIONS AND ALTERATIONS: OFFICE | Expired | |
| 2010-02-09 | T10BU00247City permit record | BUILDSMALL PORTABLE DONATION BIN | Withdrwn | |
| 2005-04-04expired 2005-12-24 | T05OT00789City permit record | SIGNSING:8776 COPE | Expired | |
| 2005-01-05finaled | T05BU00035City permit record | Fence / wallWALL:299 LF OF 6' HI RET | Final | |
| 2004-10-12expired 2004-12-11 | T04EX00978City permit record | EXCAVEXCAV:TRENCH 20LF | Closed | |
| 2004-09-10finaled | T04BU02253City permit record | SPKLRFIRE SPKR:ADD 90 & INSTALL 30LF OF 4" PIPE | Final | |
| 2004-08-19expired 2004-10-18 | T04EX00841City permit record | EXCAVEXCA:INSTALL HCS CORRECTION AND GAS WTER LINES | Closed | |
| 2004-08-05expired 2005-03-28 | T04EX00795City permit record | EXCAVEXCAV:INSTALL SIDEWALK/CURB CUT/DRIVEWAY 170LF | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2011-01-05finaled | T11FR00046Code enforcement case | Fire | Complete |
| 2010-12-07finaled | T10FR02565Code enforcement case | Fire | Complete |
| 2008-01-25finaled | T08FR00254Code enforcement case | Fire | Complete |
| 2007-12-17 | T07FR02545Code enforcement case | Fire | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85730 · Commercial & industrial reports · Homes in 85730 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 13615040B — 24 permits on file from 2004 to 2026 (6 fire operational, 3 combo, 3 excav, 2 fence / wall) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.