- Parcel
- 13613027J
- Built
- 1979 (county record)
- Jurisdiction
- Tucson
- Zoning
- RV
- Assessor use
- Travel Trailer Or Rv Park
- Parcel size
- 26.04 acres
- Building area
- 18,949 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 development package permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalCurrentA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “*URGENT/EMERGENCY NEED* Customer elected to have HVAC system replaced as opposed to repairing existing system. Replacement of existing system "like for like". Remove existing HVAC system and replace with: 15.2 SEER2 3 TON MH PACK HP 15.2 SEER2 Two-Stage Compressor Dedicated Multipositional American Made”. Last permitted this year (2026). City inspection record: RSBU - Building Final approved 2026-02-27. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-RES-0226-00692 — Installation of new 2 ton mini split system. 2 indoor heads, condenser on ground.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-04-14 (TC-RES-0426-01855) — *URGENT/EMERGENCY NEED* Customer elected to have HVAC system replaced as opposed to repairing existing system. Replacement of existing system "like for like". Remove existing HVAC system and replace with: 15.2 SEER2 3 TON MH PACK HP 15.2 SEER2 Two-Stage Compressor Dedicated Multipositional American Made.
Permit history (35)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-04-14expires 2027-05-18 | TC-RES-0426-01855City permit record | Residential Building - One or Two Family*URGENT/EMERGENCY NEED* Customer elected to have HVAC system replaced as opposed to repairing existing system. Replacement of existing system "like for like". Remove existing HVAC system and replace with: 15.2 SEER2 3 TON MH PACK HP 15.2 SEER2 Two-Stage Compressor Dedicated Multipositional American Made | Issued | |
| 2026-02-09finaled | TC-RES-0226-00692City permit record | Residential Building - One or Two FamilyInstallation of new 2 ton mini split system. 2 indoor heads, condenser on ground. | Complete | |
| 2026-01-20expires 2027-01-26 | TC-RES-0126-00290City permit record | Residential Building - One or Two FamilyInstallation of new 1.5 ton mini split system, condenser on ground. | Issued | |
| 2025-10-28finaled | TC-RES-1025-05249City permit record | Residential Building - One or Two FamilyHVAC INSTALL: 2 TON SPLIT SYSTEM HEAT PUMP UNIT | Complete | |
| 2025-10-07finaled | TZ-CMP-1025-00176City permit record | Zoning Verification LetterZoning Verification for “Rincon Country East” located at 8989 E Escalante Rd, Tucson, AZ 85730, Parcel # 13613027J | Complete | |
| 2025-01-27 | TC-RES-0125-00520City permit record | Residential Building - One or Two FamilyHVAC Replacement | Expired | |
| 2025-01-24 | TC-RES-0125-00480City permit record | Residential Building - One or Two FamilyHVAC Unit Replacement | Fees due | |
| 2024-09-05finaled | TC-RES-0924-05123City permit record | Residential Building - One or Two FamilyGas line reconnect. | Complete |
Show 27 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-05-09expired 2024-11-25 | TC-RES-0524-02853City permit record | Fence / wallWe are adding a 3/4 inch pipe to an existing 1/2 inch pipe. The gas line pipe will run to a new gas meter installed by Southwestern Gas Co. The length of the new pipe will be less than 15 ft. The new pipe will be attached to an existing structural wall of the park model unit number 172. | Issued | |
| 2023-08-01expired 2024-02-04 | TC-RES-0823-06955City permit record | Residential Building - One or Two FamilyHVAC Swap | Issued | |
| 2023-05-08expired 2023-11-04 | TC-RES-0523-05005City permit record | Residential Building - One or Two FamilyReplace 28gal electric water heater, like for like | Issued | |
| 2023-01-16expired 2023-11-18 | TC-RES-0123-02125City permit record | Residential Building - One or Two Familyinstall new mini split | Issued | |
| 2022-05-18finaled | DP22-0128City permit record | Development PackageSite/Grading - Rincon Country East RV Resort. Courtyard improvements and lobby renovations. | Complete | |
| 2022-05-10finaled | T22CM03585City permit record | Commercial BuildingCourtyard improvements and lobby renovations | Complete | |
| 2022-02-11expired 2022-08-21 | T22CM01084City permit record | Commercial BuildingNew Gas Line | Expired | |
| 2022-01-26expired 2022-08-03 | T22CM00608City permit record | Commercial BuildingNew Gas Line | Expired | |
| 2019-12-18finaled | T19CM09304City permit record | COMBONEW GASLINE | Final | |
| 2019-03-18finaled | T19CM01911City permit record | COMBO10 GAL ELECTRIC WATER HEATER REPLACEMENT LIKE FOR LIKE | Final | |
| 2019-03-18 | T19CM01913City permit record | COMBO10 GAL ELECTRIC WATER HEATER REPLACEMENT LIKE FOR LIKE | Withdrwn | |
| 2017-03-24finaled | T17CM02332City permit record | COMBOGAS RECONNECT | Final | |
| 2014-10-21finaled | T14BU01157City permit record | BUILDFIXED SYSTEM | Final | |
| 2014-07-23expired 2015-03-15 | T14CM04664City permit record | COMBOHOOD EXTENSION | Expired | |
| 2012-03-05finaled | T12CM00849City permit record | COMBOEXTEND GAS LINE TO METER LOCATION - RES | Final | |
| 2011-09-27finaled | T11ME00271City permit record | MECHREPLACE EXISTING 2.5 TON HEAT PUMP PACKAGE UNIT, GROUND LEVEL | Final | |
| 2008-08-19expired 2009-02-15 | T08ME00502City permit record | MECHReplace exsisting 3ton package heatpump. | Expired | |
| 2006-11-28finaled | T06PL02170City permit record | PLUMBGAS LINE:REPAIR | Final | |
| 2006-09-07finaled | T06ME00536City permit record | MECHINSTALL: 2 1/2 TON PACKAGE UNIT (APA) | Final | |
| 2004-02-05expired 2004-08-03 | T04PL00244City permit record | PLUMBREPLACE:WATER HEATER | Withdrwn | |
| 2003-09-30finaled | T03PL01610City permit record | PLUMBREPLACE:WATER HEATER (APA) | Final | |
| 2000-02-15expired 2000-08-13 | T00PL00393City permit record | PLUMBWATER CONDITIONER | Expired | |
| 1999-02-12finaled | T99PL00368City permit record | PLUMBGAS LINE:DRYER | Final | |
| 1997-10-21expired 1998-04-19 | T97PL01678City permit record | PLUMBGAS LINE:PRESSURE TEST | Expired | |
| 1997-10-06expired 1998-04-06 | T97PL01519City permit record | PLUMBRECONNECT:GAS | Expired | |
| 1997-06-24finaled | T97PL00766City permit record | PLUMBGAS PRESSURE TEST | Final | |
| 1997-04-11finaled | T97PL00300City permit record | PLUMBGAS LINE:PRESSURE TEST | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (6)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-04-07 | CE-VIO0425-01441Code enforcement case | Code enforcement case | Closed - resolved |
| 2024-05-21 | CE-VIO0524-01927Code enforcement case | Code enforcement case | Closed - unfounded |
| 2020-09-23 | T20DV06413Code enforcement case | Work without permit | Referred |
| 2014-10-14 | T14DV08607Code enforcement case | Code enforcement case | Noverify |
| 2008-10-16finaled | T08FR03791Code enforcement case | Code enforcement case | Complete |
| 2003-01-31 | T03VL00089Code enforcement case | Fire | Closed |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 13613027J — 35 permits on file from 1997 to 2026 (10 residential building - one or two family, 9 plumb, 6 combo, 3 commercial building) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.