Electrical permit history — 1684 S Research Lp
1684 S Research Lp, Tucson — built 1985, with 74 permits on record. Review electrical, HVAC and remodel history with links to official records.
Electrical Property Screening Report · Commercial property
1684 S Research Lp
A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.
Verify parcel data at official source ↗
Built 1985 — 1980s commercial stock · last permitted panel/service work 2018 (finaled)
Permanent link: Electrical permit history for 1684 S Research Lp (aztucsonelectricalsolutions.com/property/135074550/1684-s-research-lp-tucson-az-85710) · Public records last checked 2026-08-22
Is it time to upgrade?
- Electrical service & distributionFinaled permit foundLast permitted 2018 (8 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T18CM04270 — ADD NEW METER TO EXISTING SERVICE
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 special events fire permit - organizer permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyLikely dueA newer 2026 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Install (24) new fire sprinkler heads in new grid ceiling”. Last permitted 2002 (24 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T02BU00512 — FIRE SPRINKLER:ADD
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
A finaled 2018 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.
- Worth confirming
A pool or spa was permitted in 2006. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
- Worth confirming
There is an electrical reconnect permit from 2004. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
- Routine
A trade permit was pulled in 2018. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
Solar and energy potential
- Roof footprint
- ≈ 72,118 sq ft (county building-footprint layer, 7 structures)
- Usable for solar, planning estimate
- ≈ 50,500 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 560 kW — roughly 1,400 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 920,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- $74,000–$120,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Irvington and Houghton”, is about 2.2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Get a commercial solar & switchgear analysis
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot, so no zone is shown here. That is a gap in this page, not a statement about the property. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 135074550 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 135074550
- Year constructed
- 1985 (assessor record)
- Permitting authority
- Tucson
- Zoning
- I-1
- Property type
- Warehouse W/ Office/ Retail
- Building area
- 67,609 sq ft
- Service on record
- City records show the 2018 permit was finalized; the permit description states “ADD NEW METER TO EXISTING SERVICE ”.
The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.
What that reading rests on. The issuing offices hold 74 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (38), addition / alteration (19), zoning compliance (4) and fire automatic extinguishing system (4). 54 of them carry a final inspection; the other 20 were issued, expired or are still open, which is not the same as work completed.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Commercial building (1): 2026 TC-COM-0826-01252
City permit record (73): 2026 TZ-CMP-0626-00111 · 2026 TF-FCP-0526-00306 · 2023 TF-FOP-0323-00587 · 2021 T21CM07882 · 2021 T21SA00310 · 2020 T20CM01167 · 2020 T20CM01714 · 2019 T19SA00424 · 2019 T19SA00306 · 2019 T19FC00103 · 2019 T18CM10039 · 2018 T18CM08797 · 2018 T18CM05556 · 2018 T18CM04270 · 2018 T18CM00920 · 2017 T17CM04648 · 2016 T16CM08114 · 2015 T14OT00692 · 2015 T15CM06896 · 2014 T14SA00414 · 2014 T14OT00307 · 2012 T12SA00156 · 2011 T11SA00106 · 2010 T10OT01903 · 2010 T10OT00987 · 2009 T09EL02773 · 2009 T09OT02650 · 2009 T09OT02610 · 2009 T09OT00312 · 2009 T09OT01439 · and 43 older — search the parcel at the office below
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 135074550. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All industrial property · Commercial property in 85710 · Commercial & industrial reports · Homes in 85710 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this property compares nearby
Properties on S RESEARCH LP hold 413 City permits on record, 37 of them since 2022.
Computed from the same public records as this report — counts and years, not an appraisal.
Complete permit record (74 entries)
Every permit and case we hold for this parcel, newest first. Each number links to the official file.
| Year | Number | Type | Status |
|---|---|---|---|
| 2026 | TC-COM-0826-01252 | Commercial Trade Permit | Inspections |
| 2026 | TZ-CMP-0626-00111 | Zoning Compliance | In Review |
| 2026 | TF-FCP-0526-00306 | Fire Automatic Extinguishing System Permit | Issued |
| 2023 | TF-FOP-0323-00587 | Special Events Fire Permit - Organizer | Complete |
| 2021 | T21CM07882 | Commercial Trade Permit | Expired |
| 2021 | T21SA00310 | Zoning Compliance | Complete |
| 2020 | T20CM01167 | Commercial Addition/Alteration Permit | Expired |
| 2020 | T20CM01714 | Commercial Trade Permit | Expired |
| 2019 | T19SA00424 | Zoning Compliance | Complete |
| 2019 | T19SA00306 | Zoning Compliance | Complete |
| 2019 | T19FC00103 | Fire Automatic Extinguishing System Permit | Complete |
| 2019 | T18CM10039 | Commercial Addition/Alteration Permit | Complete |
| 2018 | T18CM08797 | Commercial Trade Permit | Complete |
| 2018 | T18CM05556 | Commercial Trade Permit | Complete |
| 2018 | T18CM04270 | Commercial Trade Permit | Complete |
| 2018 | T18CM00920 | Commercial Trade Permit | Complete |
| 2017 | T17CM04648 | Commercial Addition/Alteration Permit | Canceled |
| 2016 | T16CM08114 | Commercial Addition/Alteration Permit | Complete |
| 2015 | T14OT00692 | Permanent Sign Permit | Canceled |
| 2015 | T15CM06896 | Commercial Trade Permit | Complete |
| 2014 | T14SA00414 | Marijuana Use Authorization | Withdrawn |
| 2014 | T14OT00307 | Permanent Sign Permit | Complete |
| 2012 | T12SA00156 | Marijuana Use Authorization | Canceled |
| 2011 | T11SA00106 | Marijuana Use Authorization | Canceled |
| 2010 | T10OT01903 | Commercial Addition/Alteration Permit | Complete |
| 2010 | T10OT00987 | Commercial Addition/Alteration Permit | Complete |
| 2009 | T09EL02773 | Commercial Trade Permit | Complete |
| 2009 | T09OT02650 | Commercial Addition/Alteration Permit | Complete |
| 2009 | T09OT02610 | Commercial Addition/Alteration Permit | Complete |
| 2009 | T09OT00312 | Commercial Addition/Alteration Permit | Complete |
| 2009 | T09OT01439 | Commercial Addition/Alteration Permit | Canceled |
| 2009 | T09OT00726 | Permanent Sign Permit | Complete |
| 2009 | T09OT00625 | Commercial Addition/Alteration Permit | Complete |
| 2009 | T09OT00075 | Commercial Addition/Alteration Permit | Complete |
| 2008 | T08OT01580 | Commercial Addition/Alteration Permit | Complete |
| 2007 | T07OT00318 | Permanent Sign Permit | Complete |
| 2006 | T06CM06525 | Commercial Addition/Alteration Permit | Complete |
| 2006 | T06OT03154 | Commercial Addition/Alteration Permit | Withdrawn |
| 2006 | T06EL02135 | Commercial Trade Permit | Complete |
| 2006 | T06OT01618 | Peddler Permit | Canceled |
| 2005 | T05EL02123 | Commercial Trade Permit | Complete |
| 2005 | T05ME00567 | Commercial Trade Permit | Complete |
| 2005 | T05CM02129 | Commercial Addition/Alteration Permit | Complete |
| 2004 | T04EL00817 | Commercial Trade Permit | Complete |
| 2002 | T02EL02074 | Commercial Trade Permit | Canceled |
| 2002 | T02ME00308 | Residential Trade Permit | Complete |
| 2002 | T02EL00987 | Commercial Trade Permit | Complete |
| 2002 | T02BU00512 | Fire Automatic Extinguishing System Permit | Complete |
| 2002 | T02BU00241 | Fire Automatic Extinguishing System Permit | Complete |
| 2001 | T01CM05986 | Commercial Addition/Alteration Permit | Complete |
| 2001 | T01EL02038 | Residential Trade Permit | Complete |
| 2001 | T01EL02039 | Residential Trade Permit | Complete |
| 2001 | T01CM01180 | Commercial Addition/Alteration Permit | Complete |
| 2001 | T01CM00155 | Commercial Trade Permit | Complete |
| 2001 | T01EL00200 | Commercial Trade Permit | Complete |
| 2000 | T00CM05423 | Commercial Trade Permit | Withdrawn |
| 1999 | T99EL02134 | Commercial Trade Permit | Complete |
| 1999 | T99EL02135 | Commercial Trade Permit | Complete |
| 1999 | T99EL02136 | Commercial Trade Permit | Complete |
| 1999 | T99EL02137 | Commercial Trade Permit | Complete |
| 1999 | T99EL02138 | Commercial Trade Permit | Complete |
| 1999 | T99EL02132 | Commercial Trade Permit | Complete |
| 1999 | T99EL02139 | Residential Trade Permit | Complete |
| 1999 | T99CM00027 | Commercial Trade Permit | Canceled |
| 1999 | T99EL00047 | Commercial Trade Permit | Canceled |
| 1998 | T98EL00999 | Commercial Trade Permit | Complete |
| 1998 | T98EL00380 | Commercial Trade Permit | Complete |
| 1998 | T98CM00301 | Commercial Addition/Alteration Permit | Canceled |
| 1997 | T97EL02122 | Commercial Trade Permit | Withdrawn |
| 1997 | T97PL01958 | Commercial Trade Permit | Complete |
| 1997 | T97PL01784 | Residential Trade Permit | Complete |
| 1997 | T97PL01702 | Commercial Trade Permit | Complete |
| 1997 | T97EL01710 | Commercial Trade Permit | Complete |
| 1997 | T97EL00936 | Commercial Trade Permit | Complete |
prints this report — permits, comparisons and sources — as a clean document
How this report was built
This is a reading of public records for parcel 135074550 — 74 City permits on file from 1997 to 2026 — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.
The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.