Electrical permit history — 7510 E 22nd St

7510 E 22nd St, Tucson — built 1995, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

7510 E 22nd St

Built 1995 — 1990s commercial stock · HVAC 2001 (permit expired without a confirmed final)

Parcel
13507330G
Built
1995 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
1.13 acres
Building area
3,767 sq ft (assessor record)
Sewer
Connection on file (2018) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 7510 E 22nd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 1997 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2001 permit specifies this work (the permit description states “REPLACE:2-3 TON A/C (APA)”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. Contractor of record: CONTEMPORARY REFRIGERATION INC. T01ME00891 — REPLACE:2-3 TON A/C (APA)
  • Fire alarm & life safetyCurrentLast permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00591 — Replacing (2) Unleaded(87) West Fill/Vapor Spill Buckets
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2025-05-21 (TR-ROW-0525-00712) — The contractor will be installing cameras onto light poles for the Tucson Police Department. Shadow Truck less than an hour per location. 60 DAY PERMIT.

Permit history (22)

Permit history for this parcel — 8 of 22 records
DateRecordWhatStatusValue
2025-05-21finaledTR-ROW-0525-00712City permit recordRight-of-Way (ROW)The contractor will be installing cameras onto light poles for the Tucson Police Department. Shadow Truck less than an hour per location. 60 DAY PERMITComplete
2025-03-31finaledTR-UTL-0325-00533City permit recordRight-of-Way (ROW) - UtilityPRJ289439-1: Cox to trench 6' to install CATV conduit for system tie.Complete
2025-01-22TD-DEV-0125-00025City permit recordDevelopment PackageRaze and rebuild of existing commercial site. Proposed 5,200 sf C-Store with 6 pumps.Expired
2017-11-03finaledT17OT01150City permit recordFence / wall5-CofC (3 WALL + 2 DF)Final
2017-07-21finaledT17FC00591City permit recordFIRECONSReplacing (2) Unleaded(87) West Fill/Vapor Spill BucketsFinal
2017-06-08finaledT17FO00512City permit recordFIREOPERCARBON DIOXIDE DETECTION SYSTEM INSTALLATION STORE# 5318Final
2017-04-20finaledT17FO00342City permit recordFIREOPERLIST OF FUEL TANKS & PRODUCT STOER #5318Final
2016-01-08finaledT16BU00020City permit recordTANKSREPL DISPENSERSFinal
Show 14 older records
Permit history for this parcel — remaining 14 records
DateRecordWhatStatusValue
2014-05-20expired 2015-09-08T14BU00524City permit recordTANKSREMOVE 3 FUEL DISPENSERS;COMMExpired
2014-03-07expired 2014-09-09T14OT00275City permit recordSIGN22ND ST. DF SIGN / REPAIR OF EXISTING MANUAL PRICE CHANGER TO EMC PRICE CHANGER / MAX 200 NIT NIGHTBRIGHTNESS.Expired
2014-02-11finaledT14CM00825City permit recordCOMBOCIRCLE KC of o
2014-02-03finaledDP14-0015City permit recordDevelopment PackageSITE FOR CIRCLE K EXPANSIONComplete
2011-04-11finaledT11OT00692City permit recordSIGNBANNER:45 DAYS 4-11-2011 TO 5-26-2011Final
2011-04-11finaledT11OT00693City permit recordSIGNPENNANT:DAYS 4-11-2011 TO 4-21-2011Final
2011-04-11finaledT11OT00695City permit recordSIGNBALLOON; 3 DAYS; 04/15/11 - 04/18/11 (T11DV01630)Final
2005-01-12finaledT05OT00067City permit recordSIGNSIGN:8323 CIRCLE K #5318Final
2004-06-25finaledT04OT01273City permit recordSIGNSIGN:7366Final
2004-06-14finaledT04EL01248City permit recordELECTREPLACE:EXISTING DISPENSERSFinal
2001-10-30expired 2002-04-28T01ME00891City permit recordMECHREPLACE:2-3 TON A/C (APA)Expired
2000-09-19expired 2002-07-08T00EL02242City permit recordELECTSIGN:ELECTRIC:1405Expired
1999-07-30expired 2000-01-26T99BU02053City permit recordTANKSTANKS:1000 GALLONSExpired
1997-09-11finaledT97CM02903City permit recordCOMBOTI:STORE REMODEL INTERIOR AND REPLACE WINDOW WITH MASONRYFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (7)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 7 of 7 records
DateRecordWhatStatus
2018-06-14T18DV03458Code enforcement caseCode enforcement caseComplian
2015-04-15T15DV02913Code enforcement caseCode enforcement caseComplian
2013-03-19T13DV01695Code enforcement caseGraffitiComplian
2011-04-29finaledT11FR00953Code enforcement caseCode enforcement caseComplete
2008-04-08finaledT08FR00855Code enforcement caseCode enforcement caseComplete
2007-10-25T07DV11516Code enforcement caseCode enforcement caseCancel
2007-06-05finaledT07FR01078Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13507330G — 22 permits on file from 1997 to 2025 (6 sign, 3 tanks, 2 development package, 2 fireoper) and 7 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.