- Parcel
- 135021330
- Built
- 1962 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-1
- Assessor use
- State School Prop
- Parcel size
- 35.48 acres
- Building area
- 318,290 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 right-of-way (row) - utility permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 right-of-way (row) - utility permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2014 (12 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T14BU01390 — FIRE SPRINKLER
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Solar was permitted here in 2018. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.
Most recent permit on record for this parcel: 2026-05-13 (TR-ROW-0526-00582) — The Tucson Police Department will be installing camera systems at 70 locations. An excel spreadsheet has been included with all the locations and pole numbers, as well as, a traffic control plan. TPD will be utilizing a TPD marked vehicle to assist with traffic safety. This permit will serge for streetlight(s): #5183.
Permit history (24)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-05-13expires 2026-08-30 | TR-ROW-0526-00582City permit record | Right-of-Way (ROW)The Tucson Police Department will be installing camera systems at 70 locations. An excel spreadsheet has been included with all the locations and pole numbers, as well as, a traffic control plan. TPD will be utilizing a TPD marked vehicle to assist with traffic safety. This permit will serge for streetlight(s): #5183 | Issued | |
| 2026-04-17finaled | TR-UTL-0426-00681City permit record | Right-of-Way (ROW) - Utilitywo#3196579 1302 s Avenida vega 14-15-19 ne replace fire hydrant at the northwest side off of e 22nd st in the shoulder in dirt area 6lf/ar | Complete | |
| 2024-03-13finaled | TR-ROW-0324-00285City permit record | Right-of-Way (ROW)The contractor will be relocating the street light power source to TEP pole for Robert Stineman for the City of Tucson. Emergency, done after the fact. | Complete | |
| 2023-02-16finaled | TR-ROW-0223-00393City permit record | Right-of-Way (ROW)Site 1 - This location is located on 22nd St. in front of Palo Verde HS. Ellison-Mills construction is coordinating the work with Palo Verde HS to take place during the spring break during the week of 3/20 to 3/24/2023. Install Approximately 315 LF of 8" Cured in Place Pipe. The Cured in Place Pipe is a trench-less technology for sewer rehabilitation and does NOT require disturbance of the earth. New concrete collars will be completed on MH's 5486-04 and MH 5486-05 per PCRWRD standard detail 211/212. | Complete | |
| 2018-04-03finaled | T18CM02469City permit record | Solar PVELECTRONIC REVIEW COMMERCIAL SOLAR PV INSTALL | L of c | |
| 2017-02-09finaled | T17RW00731City permit record | ROWStarting East of the N / E corner East Calle Betelgeux and S Avenida Sirio at TEP pole riser down pole and trench North 15' placing a 4 x4 x4 pothole for a New Vault then continuing North Trench another 3' to intercept Vault OUT OF ROW | Final | |
| 2016-06-06finaled | T16EX02193City permit record | EXCAVTEP TO REPLACE 1 POLE @ PALO VERDE HIGH SCHOOL IN THE ROW - 48" DIAMETER, NO LANE CLOSURE, TEP IS GOING TO PARK ON PRIVATE PROPERTY. | Final | |
| 2016-06-06 | T16TC01375City permit record | BARRICADTEP TO REPLACE 1 POLE @ PALO VERDE HIGH SCHOOL IN THE ROW - 48" DIAMETER, NO LANE CLOSURE, TEP IS GOING TO PARK ON PRIVATE PROPERTY. | Expired |
Show 16 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2015-06-24finaled | T15EX01898City permit record | EXCAVTRENCH APPROX. 57' TO PLACE 1-4" CONDUIT FROM AN EXISTING MANHOLE TO BOTTOM OF WOOD POLE AND FROM EXISTING POLE TO NEW HANDHOLE. WORK ORDER E.769986 ** R1 PLAN CHANGE *** TRENCH DETAIL IS BEING REVISED TO REFLECT TRENCH FROM 45' TO 210'. CUSTOMER IS VERIZON CELL SITE | Final | |
| 2015-06-24finaled | T15TC01548City permit record | BARRICADTRENCH APPROX. 57' TO PLACE 1-4" CONDUIT FROM AN EXISTING MANHOLE TO BOTTOM OF WOOD POLE AND FROM EXISTING POLE TO NEW HANDHOLE. WORK ORDER E.769986 | Final | |
| 2015-03-19expired 2016-03-26 | T15CM01853City permit record | COMBONEW CELL TOWER, SHELTER AND GENERATOR | Expired | |
| 2014-12-17finaled | T14BU01390City permit record | SPKLRFIRE SPRINKLER | Final | |
| 2013-09-11finaled | T13CM05616City permit record | Solar PVINSTALL GROUND MOUNT SOLAR SYSTEM | Final | |
| 2013-01-10expired 2013-03-11 | T13EX00024City permit record | EXCAVPLACE ANCHOR NORTHWEST OF POLE #24. BORE FROM POLE #24 THEN TURN NE AND CONTINUE TO BORE UNDER SIDEWALK FOR 61LF AND PLACE HAND HOLE IN SIDEWALK AREA | Closed | |
| 2013-01-10expired 2013-03-11 | T13EX00025City permit record | EXCAVFROM POLE #152 TRENCH 20LF, BORE 36' UNDER DRIVEWAY CONTINUE TRENCHING NORTH 107LF THEN TURN WEST AND BORE UNDER AVENIDA BEGA FOR 44LF AND SET HAND HOLE BACK OF SIDEWALK | Closed | |
| 2013-01-09expired 2013-03-10 | T13EX00017City permit record | EXCAVPLACE ANCHOR ON POLE #12 TO THE WEST | Closed | |
| 2008-06-04finaled | T08BU01029City permit record | SPKLRAdd 4 new and relocate 12 fire sprinkler heads. | Final | |
| 2008-05-27finaled | T08BU00984City permit record | SPKLRAdd three fire sprinkler heads. | Final | |
| 2008-01-14finaled | T08CM00131City permit record | COMBOCONCESSION BLDG W/GANG TOILET FACILITIES | C of o | |
| 2003-06-12expired 2003-08-11 | T03EX00609City permit record | EXCAVLANDSCAPE AND EXISTING IRRIGATION | Closed | |
| 2003-06-12 | T03OT01061City permit record | SITELANDSCAPING IMPROVEMENTS | Withdrwn | |
| 2000-06-07expired 2000-08-06 | T00EX00826City permit record | EXCAVEXCAV:900 LF OF SIDEWALK ALONG CALLE BETELGEUX | Closed | |
| 1999-02-02finaled | T99ME00135City permit record | MECHPRESSURE VESSEL CERTIFICATE:TUC-30018,30017,23148,23149,24276, | Final | |
| 1996-12-24expired 1997-02-22 | T96EX00606City permit record | EXCAVDEPRESS CURB - 40 L F | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (1)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2007-07-24 | T07DV06833Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 135021330 — 24 permits on file from 1996 to 2026 (8 excav, 3 right-of-way (row), 3 spklr, 2 solar pv) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.