Electrical permit history — 6303 E 22nd St

6303 E 22nd St, Tucson — built 1985, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6303 E 22nd St

Built 1985 — 1980s commercial stock · last permitted panel/service work 2025 (finaled)

Parcel
13424436A
Built
1985 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Car/Truck Wash Full Service
Parcel size
1.20 acres
Building area
3,840 sq ft (assessor record)
Sewer
Connection on file (1963, 1983, 2010) (county sewer connection records)
Flood zone
X (shaded) — 0.2% annual-chance flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2025 permit was finalized; the permit description states “Remove/Replace 400 amp electrical disconnect which failed.”.

See the property

County aerial photograph centered on 6303 E 22nd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2025 (1 year ago). City inspection record: COT - LCEL - Electrical Final approved 2025-01-09. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0125-00054 — Remove/Replace 400 amp electrical disconnect which failed.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2010-03-05$1,100,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-06-12 (TS-PRM-0626-00216) — Install 1 illuminated ground sign.

Permit history (19)

Permit history for this parcel — 8 of 19 records
DateRecordWhatStatusValue
2026-06-12expires 2027-02-08TS-PRM-0626-00216City permit recordSign - PermanentInstall 1 illuminated ground signIssued
2026-05-04expires 2026-12-09TS-PRM-0526-00161City permit recordFence / wallInstall 7 illuminated wall signs and install 1 illuminated ground sign.Issued
2025-12-09TE-FPU-1225-00455City permit recordFloodplain UseShell building improvement: no square footage added; no change in site conditions.Issued
2025-12-02finaledTR-ROW-1225-01458City permit recordRight-of-Way (ROW)TYPSA will perform 125 utility potholes in the Yale Estates subdivision.Complete
2025-09-26expires 2026-10-26TC-COM-0925-01765City permit recordCommercial BuildingShell building improvement: no square footage added; no change in site conditions.Inspections
2025-01-07finaledTC-COM-0125-00054City permit recordCommercial BuildingRemove/Replace 400 amp electrical disconnect which failed.Complete
2023-02-14finaledTS-PRM-0223-00186City permit recordFence / wallInstall two lighted wall signs and one non-lighted directional sign.Complete
2020-03-10finaledT20RW01551City permit recordROWREMOVING 16,000 FEET OF LEVEL 3 /CENTURYLINK AERIAL FIBER OPTIC STARTING AT 22nd ST AND ALVERNON AND ENDING AT 22ND ST AND KOLB RD. THIS PORTION OF THE PROJECT IS FROM 22ND ST/WILMOT RD TO 22ND ST/CRAYCROFT RD. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 FOR COORDINATION.Final
Show 11 older records
Permit history for this parcel — remaining 11 records
DateRecordWhatStatusValue
2017-08-03expired 2018-01-30T17OT00793City permit recordFence / wall1- ILLUM WALL SIGNExpired
2017-03-27expired 2018-01-02T17OT00323City permit recordFence / wall12 -SIGNS, 1-DD, 2-CofC DP, 3 illum wall +6 non illum wallExpired
2015-06-17expired 2015-12-22T15OT00812City permit recordFence / wallNON-ILLUM WALL SIGNSExpired
2010-06-24finaledT10OT01375City permit recordSIGN18561Final
2010-05-12expired 2010-07-11T10EX00234City permit recordEXCAVEXCA:CLOSING EXISTING DRIVEWAY ENTRANCE AND CONSTRUCT A NEW DRIVEWAY ENTRANCE WITH CURB RETURNS & CURB ACCESS RAMPClosed
2010-05-04finaledT10OT00963City permit recordSIGN18302Final
2009-11-06finaledT09CM02956City permit recordCOMBONEW:CAR WASH & CANOPIESC of o
2009-11-04T09OT02350City permit recordFLOODPLNFLOOD PLAIN USE PERMIT: CAR WASH and office building.Issued
2009-10-01finaledT09BU01488City permit recordGRADSWPPGRADING FOR NEW CARWASHFinal
2009-10-01finaledT09CM02651City permit recordCOMBOSITE REVIEW FOR NEW CAR WASHFinal
2006-02-09expired 2007-02-09T06OT00386City permit recordPEDDLERMARK HAWKINS REGULATED PEDDLER -GIFT BASKETSExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2019-04-25T19DV03318Code enforcement caseVegetationComplian
2009-09-17T09DV05399Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13424436A — 19 permits on file from 2006 to 2026 (5 fence / wall, 2 commercial building, 2 sign, 2 combo) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.