Electrical permit history — 77 S Kolb Rd

77 S Kolb Rd, Tucson — built 1975, with 48 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

77 S Kolb Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1975 — 1970s commercial stock · 48 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 trade permit permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 trade permit permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyLikely dueLast permitted 1999 (27 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T98BU00967 — FIRE SPKR:ADD 11
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2017. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2000. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2014. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 7,806 sq ft (county building-footprint layer, 3 structures)
Usable for solar, planning estimate
≈ 5,500 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 60 kW — roughly 150 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 99,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$8,000–$13,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Irvington and Houghton”, is about 3.7 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13419042A
Year constructed
1975 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Retail Strip Center
Building area
6,484 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permit with evidence of issuance is dated 2025. City records show the permit was finalized. The permit covers only the work described in that record.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permit with evidence of issuance is dated 2025. City records show the permit was finalized. The permit covers only the work described in that record.

What that reading rests on. The issuing offices hold 48 building permits for this parcel dated between 1997 and 2025. By category the work is trade permit (17), permanent sign (14), addition / alteration (10) and electrical reconnect. 26 of them carry a final inspection; the other 22 were issued, expired or are still open, which is not the same as work completed. There are 21 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13419042A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85710 · Commercial & industrial reports · Homes in 85710 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S KOLB RD hold 877 City permits on record, 179 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (69 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0426-01562Work without permitClosed - Unfounded
2026CE-VIO0126-00480Code enforcement caseClosed - Unfounded
2025SP-NRP-0625-00317Electrical ReconnectApproved
2025recordRight-of-Way (ROW) Permit - GeneralComplete
2023recordROW Permit - City CIP/JOCIn Revision
2020T20DV03938SIGN VIOLATIONCOMPLIAN
2020T20OT00284Permanent Sign PermitComplete
2019T19OT00116Permanent Sign PermitComplete
2018T18OT00029Permanent Sign PermitExpired
2017T17CM06625Commercial Trade PermitComplete
2017T17FC00079Fire Alarm System PermitCanceled
2016T15OT01621Permanent Sign PermitCanceled
2016T16OT00789Permanent Sign PermitCanceled
2016T16DV00975SIGN VIOLATIONCOMPLIAN
2016T16DV00903SIGN VIOLATIONCOMPLIAN
2016T16DV00560SIGN VIOLATIONNOVERIFY
2015T15DV08800SIGN VIOLATIONNOVERIFY
2015T15DV08801SIGN VIOLATIONNOVERIFY
2015T15BU00857Commercial Trade PermitWithdrawn
2015T15DV03350SIGN VIOLATIONCOMPLIAN
2014T14DV07186SIGN VIOLATIONCOMPLIAN
2014T14DV07127SIGN VIOLATIONNOVERIFY
2014T14DV07181SIGN VIOLATIONCOMPLIAN
2014T14DV07078CAR THROUGH COMMERCIAL BUILDINCOMPLIAN
2014T14CM05886Commercial Trade PermitComplete
2014T14DV04557SIGN VIOLATIONCOMPLIAN
2014T14DV03932SIGN VIOLATIONNOVERIFY
2013T13DV08614SIGN VIOLATIONCOMPLIAN
2013T13DV03542SIGN VIOLATIONNOVERIFY
2012T12DV01324SIGN VIOLATIONCOMPLIAN
2011T11DV01417SIGN VIOLATIONCOMPLIAN
2009T09DV02100GRAFFITICOMPLIAN
2009T09DV01774GRAFFITICANCEL
2007T07OT02656Permanent Sign PermitCanceled
2007T07OT01023Permanent Sign PermitCanceled
2006T06VL00911Permanent Sign PermitComplete
2006T06CM03050Commercial Trade PermitWithdrawn
2006T06CM02442Commercial Trade PermitWithdrawn
2006T06VL00046Permanent Sign PermitComplete
2005T05OT01449Permanent Sign PermitComplete
2005T05OT00823Permanent Sign PermitCanceled
2005T05OT00780Permanent Sign PermitComplete
2005T05EL00365Commercial Trade PermitComplete
2004T04BU00200Commercial Fence/Wall PermitCanceled
2003T03CM04653Commercial Trade PermitComplete
2003T03OT00988Development PackageComplete
2003T03CM02918Commercial Addition/Alteration PermitCanceled
2003T03OT00736Permanent Sign PermitComplete
2002T02EL02299Commercial Trade PermitCanceled
2002T02OT01074Permanent Sign PermitComplete
2002T02CM00861Commercial Addition/Alteration PermitComplete
2000T00CM04540Commercial Addition/Alteration PermitWithdrawn
2000T00OT00200Commercial Addition/Alteration PermitWithdrawn
2000T00CM02595Commercial Addition/Alteration PermitComplete
2000T00EL01480Residential Trade PermitCanceled
2000T00CM01590Commercial Addition/Alteration PermitWithdrawn
2000T00EL00743Commercial Trade PermitCanceled
2000T00CM01263Commercial Addition/Alteration PermitComplete
2000T00PL00524Commercial Trade PermitComplete
2000T00PL00523Commercial Trade PermitComplete
2000T00EL00467Commercial Trade PermitComplete
2000T00CM00137Commercial Trade PermitCanceled
2000T00PL00019Commercial Trade PermitComplete
1999T98BU00967Fire Automatic Extinguishing System PermitComplete
1999T98CM01646Commercial Addition/Alteration PermitComplete
1998T98PL01443Commercial Trade PermitComplete
1998T98CM01777Commercial Addition/Alteration PermitCanceled
1998T98EL00680Commercial Trade PermitComplete
1997T97CM01682Commercial Addition/Alteration PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13419042A — 48 City permits on file from 1997 to 2025 and 21 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-11-13.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.