Electrical permit history — 1102 S Sherwood Village Dr
1102 S Sherwood Village Dr
- Electrical service: no service or distribution permit on record for this 1986 building.
- Watch for: built 1986; distribution gear this age is often past manufacturer support.
- Other work on record: zoning compliance permit 2021, addition or alteration permit 2019, development package permit 2019, and 2 more — see the records below.
From City of Tucson permits and the Pima County Assessor, checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Possibly: no service or distribution work is on record for this 1986 building.
- Electrical service & distributionWorth checkingNo service or distribution permit on record for this 1986 building. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Worth knowing: a 2019 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalLooks currentLast permitted 2019 (7 years ago) — the permit passed final inspection. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T19CM04847 — HVAC CHANGE OUT LIKE FOR LIKE
- Fire alarm & life safetyWorth checkingNo permit on record names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofWorth checkingNo permit on record names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear.
- Worth confirming
A pool or spa was permitted in 2019. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Solar and energy potential
- Roof footprint
- ≈ 3,733 sq ft (county building-footprint layer)
- Usable for solar, planning estimate
- ≈ 2,600 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 30 kW — roughly 80 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 49,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- Estimate $4,000–$6,500 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Irvington and Houghton”, is about 2.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 134113670 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 134113670
- Year constructed
- 1986 (assessor record)
- Permitting authority
- Tucson
- Zoning
- C-1
- Property type
- Privately Owned Academic School - Charter
- Building area
- 2,996 sq ft
- Electrical service
- No service or distribution permit on record for this 1986 building. (the era estimate is from the year built, 1986 — not a measurement)
Building area comes from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
What this means for work here
The most recent permit with evidence of issuance is dated 2021. City records show the permit was finalized. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 7 building permits for this parcel dated between 2001 and 2024. Three addition or alteration permits, two development package permits, one zoning compliance permit and one trade permit. 5 of them carry a final inspection; the other 2 were issued, expired or are still open, which is not the same as work completed. There is 1 code-enforcement case recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
City permit record (7): 2024 TD-DEV-1024-00289 · 2021 T21SA00153 · 2019 T19OT00630 · 2019 DP19-0174 · 2019 T19CM04847 · 2001 T01CM04797 · 2001 T01OT00141
Code enforcement cases (1): 2010 T10DV06287
Permit records courtesy of the City of Tucson — each link opens the City’s own file. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 134113670.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85710 · Commercial & industrial reports · Homes in 85710 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 1102 S Sherwood Village Dr (aztucsonelectricalsolutions.com/property/134113670/1102-s-sherwood-village-dr-tucson-az-85710)
Electrical summary — 1102 S Sherwood Village Dr, Tucson, AZ 85710
Parcel 134113670Year built 1986Building area 2,996 sq ftPermit history City of TucsonRecord checked 13 Nov 2026
- Electrical service: no service or distribution permit on record for this 1986 building.
- Watch for: built 1986; distribution gear this age is often past manufacturer support.
- Other work on record: zoning compliance permit 2021, addition or alteration permit 2019, development package permit 2019, and 2 more — see the records below.
Permits on record, newest first
| Date | Permit | Type | Status |
|---|---|---|---|
| Oct 2024 | TD-DEV-1024-00289 | Development package permit | Open |
| Apr 2021 | T21SA00153 | Zoning compliance permit | Final |
| Aug 2019 | T19OT00630 | Addition or alteration permit | Final |
| Jul 2019 | DP19-0174 | Development package permit | Final |
| Jul 2019 | T19CM04847 | Heating & cooling | Final |
| Oct 2001 | T01CM04797 | Addition or alteration permit | Final |
Voided or withdrawn permit records: 1 (not listed).
Era flags
- Built 1986: distribution gear this age is often past manufacturer support.
Ask your inspector or engineer to check
- The main switchboard’s nameplate rating and the age and make of the distribution gear.
- Whether the arc-flash labels match the installed gear (NFPA 70E reviews them every five years).
Live report: https://www.aztucsonelectricalsolutions.com/property/134113670/1102-s-sherwood-village-dr-tucson-az-85710
How this property compares nearby
Properties on S SHERWOOD VILLAGE DR hold 163 City permits on record, 25 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 134113670 — 7 City permits on file from 2001 to 2024 and 1 code enforcement case — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. The construction year and living area on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 13 Nov 2026 from the City’s permit export of that day.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.