Electrical permit history — 140 S Camino Seco

140 S Camino Seco, Tucson — built 1986, with 94 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

140 S Camino Seco

Built 1986 — 1980s commercial stock · last permitted panel/service work 2005 (finaled)

Parcel
13409019L
Built
1986 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Warehouse W/ Office/ Retail
Parcel size
2.12 acres
Building area
35,338 sq ft (assessor record)
Sewer
Connection on file (1998) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2005 permit was finalized; the permit description states “200 amp replacement”.

See the property

County aerial photograph centered on 140 S Camino Seco, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2005 (21 years ago). City inspection record: ELECTRIC - FINAL approved 2005-10-04. Contractor of record: MEHL ELECTRIC SERVICE INC,*C. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T05EL02010 — 200 amp replacement
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 1997 pool / spa permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    There is an electrical reconnect permit from 2019. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 1997. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2025-04-15 (SP-NRP-0425-00192) — The electricity has been off for some time, and we need it turned back on as soon as possible so we can rent the space out again..

Permit history (94)

Permit history for this parcel — 8 of 94 records
DateRecordWhatStatusValue
2025-04-15expired 2025-05-15SP-NRP-0425-00192City permit recordPool / spaThe electricity has been off for some time, and we need it turned back on as soon as possible so we can rent the space out again.Inspections
2024-08-29expired 2025-12-29TC-UTL-0824-00072City permit recordUtilitiesRemove existing antennas, RRUs, and TMA. Install new antennas, RRUs and new mount.Expired
2023-08-23expired 2024-02-19TC-COM-0823-02050City permit recordAddition / alterationVOID - Duplicate Application. There is already a permit in process for this address: T22CM04858 (140 S CAMINO SECO TUCSON, AZ 85710). Please process through the permit already in process or request a withdrawal prior to submitting additional permits. - replace antennas, ancillary equipment and ground equipment as per plans for an existing carrier on an existing wireless communication facility.Void
2023-04-14expired 2023-12-01TC-COM-0423-01057City permit recordCommercial BuildingFrom TEP transformer to TEP main meter pull box need to repair broken conduit and replace conductors that were also damaged. Which feeds all meters at address. Electrical permit request per TEPIssued
2022-06-27expired 2024-05-21T22CM04858City permit recordCommercial Buildingreplace antennas, ancillary equipment and ground equipment as per plans for an existing carrier on aWithdrawn
2021-12-18expired 2023-11-05T21CM09717City permit recordCommercial BuildingCollocation of antennas, ancillary equipment and ground equipment as per plans for a new carrier onIssued
2021-12-03finaledT21RW05154City permit recordROWSTARTING AT THE VAULT ON THE SOUTHEAST SIDE OF 150 S CAMINO SECO BEGIN PULLING 48ct FIBER THRU EXISTING ATT CONDUIT HEADING SOUTH FOR 25' AND THEN TURN WEST AND ON TO PRIVATE PROPERY... ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING.Final
2021-08-31finaledT21RW04049City permit recordROWInstall 22lf of 4" fiber conduit in ROW to existing fiber vault. Work along west side of S Camino Seco, back of sidewalk, crossing gutter to storm drain. Proof of notification is required at the time of the preconstruction meeting. 1. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 2. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 3. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 4. MAINTAIN PEDESTRIAN ACCESSFinal

86 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (19)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 19 records
DateRecordWhatStatus
2026-07-28CE-VIO0726-03139Code enforcement caseGraffitiClosed - unfounded
2013-10-16T13DV07736Code enforcement caseRefuseNoverify
2011-01-31finaledT11FR00306Code enforcement caseCode enforcement caseComplete
2009-12-18finaledT09FR03821Code enforcement caseCode enforcement caseComplete
2009-07-16finaledT09FR02317Code enforcement caseCode enforcement caseComplete
2008-07-31finaledT08FR02216Code enforcement caseCode enforcement caseComplete
2007-03-16finaledT07FR00510Code enforcement caseCode enforcement caseComplete
2007-03-16T07FR00512Code enforcement caseCode enforcement caseField
Show 11 older records
Code enforcement history for this parcel — remaining 11 records
DateRecordWhatStatus
2007-02-14T07FR00329Code enforcement caseCode enforcement caseField
2006-06-06finaledT06FR01794Code enforcement caseCode enforcement caseComplete
2006-05-24finaledT06FR01466Code enforcement caseCode enforcement caseComplete
2005-02-02finaledT05FR00157Code enforcement caseFireComplete
2005-02-02finaledT05FR00158Code enforcement caseFireComplete
2004-09-01T04FR00332Code enforcement caseCode enforcement caseField
2004-09-01T04FR00333Code enforcement caseCode enforcement caseField
2004-09-01T04FR00334Code enforcement caseCode enforcement caseField
2004-09-01T04FR00335Code enforcement caseCode enforcement caseField
2004-09-01T04FR00338Code enforcement caseCode enforcement caseField
2004-09-01T04FR00339Code enforcement caseCode enforcement caseField

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13409019L — 94 permits on file from 1997 to 2025 (29 combo, 24 c-of-o, 17 elect, 6 addrnew) and 19 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.