Electrical permit history — 9505 E 22nd St

9505 E 22nd St, Tucson — built 2004, with 14 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

9505 E 22nd St

Built 2004 — 2000s commercial stock · HVAC 2021 (finaled)

Parcel
13355230B
Built
2004 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Free Standing Drugstore
Parcel size
1.74 acres
Building area
14,412 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 9505 E 22nd St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2021 (5 years ago). City inspection record: COT - LCME - Mechanical Final approved 2023-09-13. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T21CM04629 — Roof top unit replacement. 6 units and 2 exhaust fans
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0123-00264 — INSTALLATION OF NEW FIRE ALARM DEVICES & TIE INTO AN EXISTING FIRE ALARM SYSTEM.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2010-12-08$5,096,000Warranty Deed
2002-12-17$4,088,172Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2023-12-11 (TR-UTL-1223-03034) — PRJ262040-1 Cox to BORE 214' and PULL THROUGH EXISTING 226' TO INSTALL NEW CATV CONDUIT FOR SYSTEM TIE.

Permit history (14)

Permit history for this parcel — 8 of 14 records
DateRecordWhatStatusValue
2023-12-11finaledTR-UTL-1223-03034City permit recordRight-of-Way (ROW) - UtilityPRJ262040-1 Cox to BORE 214' and PULL THROUGH EXISTING 226' TO INSTALL NEW CATV CONDUIT FOR SYSTEM TIEComplete
2023-07-20expired 2024-01-16TC-COM-0723-01783City permit recordCommercial BuildingVOIDED DUPLICATE PERMIT Adding 2 dedicated 20 AMP circuit for hand dryers in men and womens restroomsVoid
2023-01-23finaledTC-COM-0123-00525City permit recordCommercial BuildingAdding 2 dedicated 20 AMP circuit for a hand dryer in the Men's & Women's restrooms.Complete
2023-01-16finaledTS-PRM-0123-00130City permit recordFence / wallInstall 5 lighted wall signs, replacement tenant panels for the monument sign, and 1 interior non-lighted signComplete
2023-01-06finaledTF-FCP-0123-00264City permit recordFire ConstructionINSTALLATION OF NEW FIRE ALARM DEVICES & TIE INTO AN EXISTING FIRE ALARM SYSTEM.Complete
2023-01-03TF-FCP-0123-00248City permit recordFire ConstructionVOID-SUBMITTED NEW PERMIT#TF-FCP-0123-00264-INSTALLATION OF NEW FIRE ALARM DEVICES & TIE INTO AN EXISTING FIRE ALARM SYSTEM.Void
2022-12-15finaledTF-FCP-1222-00206City permit recordFire ConstructionModification of existing fire sprinkler system per NFPA 13Complete
2022-11-21TC-DMO-1122-00012City permit recordDemolitionInterior demo only for master project T22CM04989Fees due
Show 6 older records
Permit history for this parcel — remaining 6 records
DateRecordWhatStatusValue
2022-07-01finaledT22CM04989City permit recordCommercial BuildingTI:WalgreensComplete
2021-06-03finaledT21CM04629City permit recordCommercial BuildingRoof top unit replacement. 6 units and 2 exhaust fansComplete
2021-05-07finaledT21FC00350City permit recordFIRECONSREPLACE ANALOG POTS LINES WITH A CELL DIALER FOR FIRE ALARM COMMUNICATIONSFinal
2018-08-31finaledT18RW03923City permit recordROWCONDUIT PROOFING EXISTING CITY OF TUCSON CONDUITS ALONG HARRISON RD FROM 22ND ST TO SPEEDWAY BL AND SPEEDWAY BL FROM CAMINO SECO TO HOUGHTON RDFinal
2014-05-23T14EX00626City permit recordEXCAVDIG UP AND REPLACE APPROX. 135LF OF 8" PVC SEWER LINE WITH 8" PVC SEWER PIPE IN ASPHALT.Closed
2010-08-18expired 2011-02-14T10BU01309City permit recordBUILDSMALL DONATION BINExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (6)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 6 of 6 records
DateRecordWhatStatus
2014-09-24T14DV07911Code enforcement caseCode enforcement caseComplian
2014-01-13T14DV00236Code enforcement caseSignComplian
2011-03-30finaledT11FR00745Code enforcement caseCode enforcement caseComplete
2009-03-12finaledT09FR00929Code enforcement caseFireComplete
2008-08-08T08DV06874Code enforcement caseSignComplian
2008-05-14finaledT08FR01226Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13355230B — 14 permits on file from 2010 to 2023 (4 commercial building, 3 fire construction, 1 right-of-way (row) - utility, 1 fence / wall) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.