Electrical permit history — 8655 E Broadway Bl

8655 E Broadway Bl, Tucson — built 1984, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

8655 E Broadway Bl

Built 1984 — 1980s commercial stock · 19 permits on record; no permitted panel/service or HVAC work among them

Parcel
13329015M
Built
1984 (assessor record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Day Care/Pre-School Ctr Private Children
Parcel size
1.33 acres
Building area
7,960 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 8655 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2015 (11 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T15BU01126 — FIRE ALARM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2018. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2026-03-18 (TR-UTL-0326-00532) — wo#3261657 8655 e broadway bl 14-15-09 se emg service repair front south side of lot in dirt 6LF/sc **emergency in progress**.

Permit history (19)

Permit history for this parcel — 8 of 19 records
DateRecordWhatStatusValue
2026-03-18expired 2026-04-17TR-UTL-0326-00532City permit recordRight-of-Way (ROW) - Utilitywo#3261657 8655 e broadway bl 14-15-09 se emg service repair front south side of lot in dirt 6LF/sc **emergency in progress**Inspections
2025-10-30finaledTF-FOP-1025-01438City permit recordFire OperationalCasa Ninos School of Montessori is a private Montessori school. We have kids from infant age to 4th grade.Complete
2024-10-11finaledTF-FOP-1024-01171City permit recordFire OperationalFire Code PermitComplete
2023-10-06finaledTF-FOP-1023-01617City permit recordFire OperationalFire Code PermitComplete
2022-10-11finaledT22FO00875City permit recordFIREOPER158 PEOPLEFinal
2021-09-21finaledT21FO00626City permit recordFIREOPER158 PERSONSFinal
2020-10-20finaledT20FO00535City permit recordFIREOPERCASA NINOS SCHOOL OF MONTESSORI - 125 PERSONSFinal
2020-02-04expired 2020-08-02T20OT00137City permit recordFence / wall1-NON ILLUM WALL SIGNExpired
Show 11 older records
Permit history for this parcel — remaining 11 records
DateRecordWhatStatusValue
2019-10-29finaledT19FO00948City permit recordFIREOPERCASA NINOS SCHOOL OF MONTESSORI - OCC 125Final
2019-08-29expired 2020-06-24T19OT00829City permit recordSign - Annual Portable90 DAY BANNER EXP ON NOV 24TH 2019Expired
2019-03-07expired 2020-01-05T19OT00210City permit recordSIGN90 DAY BANNER EXP ON JUNE 9 2019Closed
2018-09-04finaledT18FO00724City permit recordFIREOPERDAYCARE - OCC 125Final
2018-06-25finaledT18OT00680City permit recordSIGN90 DAY BANNER EXPS SEPT 9TH 2018Final
2018-02-12finaledDP18-0038City permit recordSolar PVSITE - SOLAR CANOPYComplete
2018-02-01expired 2018-11-25T18CM00824City permit recordSolar PVCANOPY WITH SOLARExpired
2017-08-10finaledT17FO00670City permit recordFIREOPERDAY CARE - OCC 125Final
2015-09-29finaledT15BU01126City permit recordBUILDFIRE ALARMFinal
2015-05-09expired 2015-07-10T15EX00887City permit recordEXCAVRiser down pole on the N/side of Broadway on the S/E side of property. From pole trench north 20ft dirt, trench continues north out of ROW. WORK ORDER NUMBER: 41520150000CTU0186Expired
2015-05-09finaledT15TC01133City permit recordBARRICADRiser down pole on the N/side of Broadway on the S/E side of property. From pole trench north 20ft dirt, trench continues north out of ROW. WORK ORDER NUMBER: 41520150000CTU0186Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2013-08-08T13DV05773Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13329015M — 19 permits on file from 2015 to 2026 (6 fireoper, 3 fire operational, 2 sign, 2 solar pv) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.