Electrical permit history — 600 N Pantano Rd

600 N Pantano Rd, Tucson — built 1983, with 60 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

600 N Pantano Rd

Built 1983 — 1980s multifamily stock · 60 permits on record; no permitted panel/service or HVAC work among them

Parcel
13324002H
Built
1983 (county record)
Jurisdiction
Tucson
Zoning
R-3
Assessor use
Apartments 100+ Units 3 Or More Story
Parcel size
12.55 acres
Building area
261,135 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 600 N Pantano Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2015 combo permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2012. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2024-10-17 (TC-COM-1024-01997) — *EMERGENCY* Replace the bussing tabs for the circuit breaker for Unit 1407 like for like. This is an existing 6 pack meter with only 1407 being affected. There is no other work being done in the other 5 meters..

Permit history (60)

Permit history for this parcel — 8 of 60 records
DateRecordWhatStatusValue
2024-10-17finaledTC-COM-1024-01997City permit recordCommercial Building*EMERGENCY* Replace the bussing tabs for the circuit breaker for Unit 1407 like for like. This is an existing 6 pack meter with only 1407 being affected. There is no other work being done in the other 5 meters.Complete
2024-05-17finaledTR-UTL-0524-00994City permit recordRight-of-Way (ROW) - UtilityPlace 1320 ft aerial fiber on existing power poles, Dirt trench with 2" conduit 1252 ft, bore 366 ft with 2" conduit and remove and replace 3'x7' section of asphalt, for First Digital fiberComplete
2024-01-03finaledTR-UTL-0124-00017City permit recordRight-of-Way (ROW) - UtilityPermit 1 of 3. WO 6339123. Replace 12 poles & 5,215' of overhead wire. RE: Expired Permits TR-UTL-1122-00314 & TR-UTL-0423-01413. TEP POC: Juan Valenzuela / Juanvalenzuela@tep.com / (520) 603-2169 Update - Renewal/Extension- Request for 90 day Renewal as of 4/28/2024 .Complete
2023-12-13TR-UTL-1223-03057City permit recordRight-of-Way (ROW) - UtilityContinuation of Expired - Permit TR-UTL-0423-01413 & TR-UTL-0423-01413 - WO 6339123. Install 24 Poles & 12,060' of overhead wire. Remove 26 Poles & 11,020' of overhead wire.Void
2023-09-19finaledTR-ROW-0923-01159City permit recordRight-of-Way (ROW)Installation of Fiber optic cable in existing underground conduit to relocate the existing fiber from aerial to underground.Complete
2023-08-01finaledTZ-CMP-0823-00149City permit recordZoning Verification LetterI am looking for a letter verifying the zoning of the multifamily property called Canyon Oaks located at 600 N Pantano Rd, Tucson, AZ with parcel number 13324002H. Thanks!Complete
2023-04-28finaledTR-UTL-0423-01413City permit recordRight-of-Way (ROW) - UtilityWO#6339123. Install 25 Poles & 12,145' of overhead wire. RE: Existing Permit TR-UTL-1122-00314. Expiring 05/13/23 - WO 6339123. Install 25 Poles & 12,145' of overhead wire. Remove 27 Poles & 11,105' of overhead wire.Complete
2022-11-22finaledTR-UTL-1122-00314City permit recordRight-of-Way (ROW) - UtilityWO#6339123. Install 25 Poles & 12,145' of overhead wire. Remove 27 Poles & 11,105' of overhead wire.Complete

52 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (37)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 37 records
DateRecordWhatStatus
2026-05-05CE-VIO0526-01990Code enforcement caseCode enforcement caseClosed - resolved
2025-11-28CE-VIO1125-05183Code enforcement caseCode enforcement caseClosed - resolved
2025-02-11CE-VIO0225-00643Code enforcement caseCode enforcement caseClosed - resolved
2024-09-12CE-VIO0924-03677Code enforcement caseCode enforcement caseClosed - unfounded
2021-08-04T21DV04975Code enforcement caseCode enforcement caseNoverify
2020-11-19T20DV07522Code enforcement caseCode enforcement caseReferred
2020-08-03T20DV05238Code enforcement caseElectricalComplian
2019-07-25T19DV06039Code enforcement caseCode enforcement caseNoverify
Show 29 older records
Code enforcement history for this parcel — remaining 29 records
DateRecordWhatStatus
2018-04-20T18DV02226Code enforcement caseCode enforcement caseComplian
2018-02-14T18DV00794Code enforcement caseCode enforcement caseComplian
2018-01-05T18DV00123Code enforcement caseCode enforcement caseNoverify
2017-02-22T17DV00758Code enforcement caseElectricalComplian
2015-04-21T15DV03017Code enforcement caseFireComplian
2014-12-09T14DV10013Code enforcement caseCode enforcement caseComplian
2014-11-05T14DV09239Code enforcement caseCode enforcement caseComplian
2014-09-04T14DV06925Code enforcement caseCode enforcement caseComplian
2014-05-19T14DV03262Code enforcement caseCode enforcement caseNoverify
2013-07-26T13DV05410Code enforcement caseCode enforcement caseComplian
2012-12-24T12DV11289Code enforcement caseCode enforcement caseComplian
2012-12-17T12DV11140Code enforcement caseCode enforcement caseComplian
2011-03-15T11DV01620Code enforcement caseCode enforcement caseComplian
2010-07-20T10DV04710Code enforcement caseCode enforcement caseNoverify
2010-04-19finaledT10FR00767Code enforcement caseCode enforcement caseComplete
2010-04-14T10DV02126Code enforcement caseCode enforcement caseComplian
2009-12-10T09DV06807Code enforcement caseWork without permitCourtcmp
2008-12-10T08DV11267Code enforcement caseSignComplian
2007-10-04T07DV10378Code enforcement caseSignComplian
2007-08-14T07DV07652Code enforcement caseCode enforcement caseComplian
2007-03-21finaledT07FR00537Code enforcement caseCode enforcement caseComplete
2005-08-24T05FR01338Code enforcement caseCode enforcement caseField
2005-08-10finaledT05FR01248Code enforcement caseCode enforcement caseComplete
2005-08-02T05FR01199Code enforcement caseCode enforcement casePrecite
2000-10-24T00VL01525Code enforcement caseSignComplian
2000-04-05T00VL00439Code enforcement caseSignComplian
1999-03-31T99VL00881Code enforcement caseSignComplian
1998-12-02T98VL01320Code enforcement caseFireClosed
1998-11-09T98VL01199Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13324002H — 60 permits on file from 1997 to 2024 (24 combo, 15 sign, 6 elect, 5 right-of-way (row) - utility) and 37 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.