Electrical permit history — 7685 E Broadway Bl

7685 E Broadway Bl, Tucson — built 2003, with 38 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

7685 E Broadway Bl

Built 2003 — 2000s commercial stock · HVAC 2017 (finaled)

Parcel
13323356A
Built
2003 (assessor record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Warehhouse Type Store
Parcel size
14.66 acres
Building area
115,098 sq ft (assessor record)
Sewer
Connection on file (2002) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 7685 E Broadway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2017 (9 years ago). City inspection record: MECHANICAL - FINAL approved 2018-02-02. Contractor of record: LENNOX NATIONAL ACCOUNT SERVICES LLC. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T17CM08354 — HVAC REPLACEMENT
  • Fire alarm & life safetyCurrentLast permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0226-00127 — Fire alarm TI: Replacement of cellular dialer
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-05-08 (TF-FOP-0526-00639) — HOME DEPOT #410 - CFW retail sales.

Permit history (38)

Permit history for this parcel — 8 of 38 records
DateRecordWhatStatusValue
2026-05-08finaledTF-FOP-0526-00639City permit recordFire OperationalHOME DEPOT #410 - CFW retail salesComplete
2026-02-25finaledTF-FCP-0226-00127City permit recordFire ConstructionFire alarm TI: Replacement of cellular dialerInspections complete
2025-05-08finaledTF-FOP-0525-00655City permit recordFire OperationalHOME DEPOT #410 - CFW retail salesComplete
2024-12-02finaledTF-FOP-1224-01432City permit recordFire OperationalHOME DEPOT 410 - CFW RETAIL SALESComplete
2023-08-14finaledTZ-REV-0823-00031City permit recordZoning Review 60 DayFencing for accommodation of Seasonal sales of live goods and Christmas tree lot.Complete
2023-08-09TZ-PMT-0823-00090City permit recordFence / wallVOID - INCORRECT PERMIT TYPE - Temporary fence enclosure to accommodate seasonal sales events.Void
2022-12-02finaledTR-UTL-1222-00365City permit recordRight-of-Way (ROW) - UtilityPRJ236910--1 Cox to start on the North side of E Broadway Blvd, East of Chuck Huckleberry Loop, Tie into existing, Aerial, Overlash .48 ct Fiber East 324' Riser down, Bore 178' East Trench 6' To out of rowComplete
2021-07-23finaledT21RW03461City permit recordROWENTRANCE BEHIND THE HOME DEPOT IS VERY NARROW AND FOR THAT REASON SEMI TRUCKS ARE DRIVING OVER THE SIDEWALK AND VERTICAL CURB. CURRENT ENTRANCE IS 25' WIDE, IT NEEDS TO WIDEN TO 35' OR MORE IF POSSIBLE. CURRENT SIDEWALK, CURB, HANDICAP RAMPS AND SIDEWALK NEED TO BE REMOVED AND RE-DESIGNED FOR THE CURRENT TRAFFIC FLOW. TO INSTALL LONGER CURB RETURNS WITH TYPE 2 DIRECTIONAL CURB ACCESS RAMPS PER PAG SD 207Final
Show 30 older records
Permit history for this parcel — remaining 30 records
DateRecordWhatStatusValue
2020-11-27expired 2021-07-11T20BU00521City permit recordFence / wallFreestanding Fence for Christmas tree lot. 84ft in length and 72ft wide. See attachment highlighted in red.Issued
2019-11-20T19BU00590City permit recordFence / wallCHAIN LINK FENCEWithdrwn
2019-11-01T19RW06794City permit recordRight-of-Way (ROW)SR 19R3526 REPAIR LEAKING MAIN AT THE FRONT SIDE OF THE LOT. *EMERGENCY*; Work Order: 19R3526Submitted
2019-02-04expired 2020-04-04T19FC00096City permit recordFire ConstructionAutomatic Fire Extingshing Sys - NEW FIRE SPRINKLER SYSTEM IN AEROSOL DISPLAY AREA.; Commercial Fire Sprinkler Systems - Modification of heads: 4Expired
2018-11-06finaledT18FO00974City permit recordFIREOPERHOME DEPOT TENT (1) 40 X 150 SET- UP DATE: 11.13.18 TAKE DOWN DATE: 12.26.18 TENT FOR CHRISTMAS TREESFinal
2018-01-19finaledT18FO00075City permit recordFIREOPERSpecial Event - one Tent 40x80 *** UP FOR ONE MONTH *** Set-up: 01/22/2018 Onsite Contact: Rodrigo 302-1341Final
2017-11-13finaledT17FO00964City permit recordFIREOPERSPECIAL OLYMPICS - 1 TENT SETUP DATE 11/15/17Final
2017-11-08finaledT17CM08354City permit recordCOMBOHVAC REPLACEMENTFinal
2017-07-06finaledT17CM05189City permit recordCOMBOREPL MAIN BREAKERFinal
2017-02-07finaledT17FO00076City permit recordFIREOPER40 x 80 tent for carpet sale set-up 2-13-2017 contact: Rodrigo 302-1341Final
2016-11-29finaledT16FO00129City permit recordFIREOPERChristmas Tree lotFinal
2016-08-15finaledT16RW01057City permit recordROWSUNLAND ASPHALT WILL BE MILLING AND PAVING THE ENTRANCE DRIVE TO HOME DEPOT OVER 3 DAY PERIOD. NEED TO BLOCK THE DEDICATED TURN LANE AND DECEL LANE COMING OFF BROADWAY.Final
2016-02-19T16BU00272City permit recordFence / wallTEMPORARY FENCEWithdrwn
2015-11-30expired 2016-05-29T15BU01380City permit recordTENTSTENT PERMITExpired
2015-11-17finaledT15BU01337City permit recordTENTSTENTFinal
2015-03-02expired 2015-05-01T15EX00201City permit recordEXCAVTHIS PROJECT WILL BORE 933' 1-1 1/4" CONDUITClosed
2014-11-13T14BU01260City permit recordTENTSXMAS TREE LOTWithdrwn
2014-11-12finaledT14BU01243City permit recordTENTSTENTFinal
2014-11-05finaledT14BU01209City permit recordTENTSTENTFinal
2014-11-05T14BU01211City permit recordTENTSTENTVoid
2013-12-02expired 2014-05-31T13BU01320City permit recordTENTSTENTExpired
2013-11-08finaledT13BU01240City permit recordTENTSTENTFinal
2013-03-15finaledT13BU00310City permit recordTENTSTENTFinal
2012-11-08finaledT12BU01317City permit recordTENTSTENTFinal
2011-11-16expired 2012-05-14T11EL02974City permit recordELECTRECONNECT ELECTRICAL SERVICE FOR CHRISTMAS TREE LOTClosed
2011-10-18finaledT11BU01368City permit recordTENTSTENTFinal
2011-09-28expired 2012-09-27T11OT01859City permit recordPEDDLERSPORTS DOGS REGULATED PEDDLERExpired
2011-06-24T11BU00859City permit recordBUILD40 x 40 CANOPYVoid
2011-06-24finaledT11BU00860City permit recordTENTS40 x 40 CANOPYFinal
2006-01-31finaledD06-0006City permit recordDevelopment PackageUS BANKComplete

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (12)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 12 records
DateRecordWhatStatus
2022-12-15CE-VIO1222-00959Code enforcement caseSignClosed - resolved
2022-01-05T22DV00092Code enforcement caseRefuseNoverify
2019-12-04T19DV09189Code enforcement caseGraffitiNoverify
2019-05-17T19DV04095Code enforcement caseCode enforcement caseNoverify
2018-05-02T18DV02485Code enforcement caseCode enforcement caseNoverify
2017-08-09T17DV03562Housing code violationGRAFFITIrecorded before 2023NOVERIFY
2017-07-12T17DV02999Code enforcement caseCode enforcement caseNoverify
2014-02-14T14DV00908Code enforcement caseGraffitiComplian
Show 4 older records
Code enforcement history for this parcel — remaining 4 records
DateRecordWhatStatus
2013-05-07T13DV03001Housing code violationCAR THROUGH COMMERCIAL BUILDINrecorded before 2023COMPLIAN
2012-11-14T12DV10517Code enforcement caseGraffitiReferred
2008-07-25T08DV06400Housing code violationCOMMERCIAL ZONINGrecorded before 2023NOVERIFY
2008-03-06T08DV01846Housing code violationPAINT DISTrecorded before 2023CANCEL

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13323356A — 38 permits on file from 2006 to 2026 (12 tents, 5 fireoper, 4 fence / wall, 3 fire operational) and 12 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.