Electrical permit history — 7700 E Speedway Bl

7700 E Speedway Bl, Tucson — built 1980, with 51 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

7700 E Speedway Bl

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1980 — 1980s multifamily stock · last permitted panel/service work 2026 (finaled) · HVAC 1998 (finaled) · 3 open code cases

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted this year (2026). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0326-00439 — Provide And Install New Like for Like 200 Amp 42 Space Panel In Place Of Existing Damaged By Water
  • Heating, cooling & mechanicalLikely dueLast permitted 1998 (28 years ago). The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T98ME00419 — BOILER:RETUBE
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2026 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There are 3 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2026. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2024. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    Solar equipment was permitted here in 2011 — the permit category covers PV, solar water heating and pool heating alike. If it was PV, there is an existing interconnection and the busbar already carries backfeed, which constrains what else can be added under the 120% rule; a thermal system carries no such constraint. Worth confirming which it is.

  • Routine

    A trade permit was pulled in 2024. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 148,297 sq ft (county building-footprint layer, 26 structures)
Usable for solar, planning estimate
≈ 103,800 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,140 kW — roughly 2,850 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,880,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$150,000–$244,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Irvington and Houghton”, is about 4.3 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13323093C
Year constructed
1980 (assessor record)
Permitting authority
Tucson
Zoning
C-1
Property type
Apartments 100+ Units 3 Or More Story
Building area
216,953 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air
Service on record
City records show the 2026 permit was finalized; the permit description states “Provide And Install New Like for Like 200 Amp 42 Space Panel In Place Of Existing Damaged By Water”.

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 51 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (19), electrical reconnect (12), permanent sign (9) and addition / alteration (5). 36 of them carry a final inspection; the other 15 were issued, expired or are still open, which is not the same as work completed. There are 74 code-enforcement cases recorded against the parcel, 3 of which are open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13323093C. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85710 · Commercial & industrial reports · Homes in 85710 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E SPEEDWAY BL hold 3,258 City permits on record, 697 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (125 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0826-03524Code enforcement caseNotice of Violation
2026CE-VIO0726-02851Code enforcement caseClosed - Unfounded
2026CE-VIO0726-02849Code enforcement caseActive
2026CE-VIO0526-02192Code enforcement caseReferred
2026CE-VIO0526-02191Code enforcement caseNotice of Violation
2026TC-COM-0326-00439Commercial Addition/Alteration PermitInspections Complete
2026CE-VIO0326-01111Code enforcement caseClosed - Resolved
2026CE-VIO0226-00862Code enforcement caseClosed - Resolved
2025CE-VIO0925-04220Code enforcement caseClosed - Resolved
2025CE-VIO0925-04202Code enforcement caseClosed - Unfounded
2025CE-VIO0925-04152Code enforcement caseReferred
2025CE-VIO0925-04087Code enforcement caseClosed - Resolved
2025CE-VIO0925-03739Code enforcement caseClosed - Resolved
2025TC-COM-1224-02349Commercial Trade PermitInspections
2025TC-COM-1124-02233Commercial Addition/Alteration PermitInspections
2025TC-COM-1124-02232Commercial Addition/Alteration PermitInspections
2024SP-NRP-1024-00091Electrical ReconnectExpired
2024SP-NRP-1024-00090Electrical ReconnectExpired
2024CE-VIO1024-04271Code enforcement caseClosed - Unfounded
2024SP-NRP-1024-00013Electrical ReconnectComplete
2024SP-NRP-1024-00019Electrical ReconnectComplete
2024SP-NRP-1024-00006Electrical ReconnectComplete
2024SP-NRP-1024-00007Electrical ReconnectComplete
2024TC-RES-0924-05507Electrical ReconnectComplete
2024SP-NRP-1024-00017Electrical ReconnectComplete
2024SP-NRP-1024-00008Electrical ReconnectComplete
2024TC-RES-0924-05506Electrical ReconnectComplete
2024SP-NRP-1024-00011Electrical ReconnectComplete
2024SP-NRP-1024-00009Electrical ReconnectComplete
2024CE-VIO1024-03986Code enforcement caseClosed - Resolved
2024CE-VIO0724-02852Code enforcement caseClosed - Unfounded
2024TC-COM-0624-01181Commercial Trade PermitComplete
2024CE-VIO0524-01726Code enforcement caseClosed - Unfounded
2024CE-VIO0424-01256FireClosed - Unfounded
2024CE-VIO0324-00855FireClosed - Resolved
2024CE-VIO0224-00473Code enforcement caseClosed - Resolved
2024CE-VIO0124-00233ElectricalClosed - Resolved
2024CE-VIO0124-00041RefuseClosed - Resolved
2023CE-VIO1123-06554Code enforcement caseClosed - Resolved
2023CE-VIO1023-05940Code enforcement caseClosed - Resolved
2023CE-VIO1023-05893Code enforcement caseClosed - Unfounded
2023CE-VIO0923-05850Code enforcement caseClosed - Resolved
2023CE-VIO0823-04944Code enforcement caseClosed - Unfounded
2023CE-VIO0723-04419Code enforcement caseClosed - Resolved
2023CE-VIO0623-04237Code enforcement caseClosed - Unfounded
2023CE-VIO0523-03524Code enforcement caseClosed - Resolved
2023CE-VIO0523-03378Code enforcement caseClosed - Resolved
2023CE-VIO0523-03354Code enforcement caseClosed - Unfounded
2023CE-VIO0323-02322Code enforcement caseClosed - Resolved
2023CE-VIO0123-01293Code enforcement caseClosed - Resolved
2022CE-VIO1222-01127Code enforcement caseClosed - Resolved
2022CE-VIO1122-00064Code enforcement caseClosed - Unfounded
2022T22SA00250Zoning ComplianceComplete
2022T22DV02648RES: MINIMUM HOUSINGNOVERIFY
2022T22DV01455RES: MINIMUM HOUSINGCOMPLIAN
2022T22DV00170RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV09019RESIDENTIAL FIRECANCEL
2021T21DV08441RES: MINIMUM HOUSINGNOVERIFY
2021T21DV05991RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV05273RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV05274RES: MINIMUM HOUSINGCOMPLIAN
2020T20CM04881Commercial Trade PermitComplete
2019T19DV09357HOMELESS CAMPSNOVERIFY
2019T19DV09069HOMELESS CAMPSREFERRED
2018T18DV02430REFUSECOMPLIAN
2018T18DV00333RES: MINIMUM HOUSINGNOVERIFY
2018T18CM00005Commercial Trade PermitCanceled
2017T17CM09522Commercial Trade PermitWithdrawn
2017T17DV06776EMERGENCYCOMPLIAN
2017T17CM07476Commercial Trade PermitComplete
2017T17DV04657WORK WITHOUT PERMITS-COMMERCLCOMPLIAN
2017T17CM06583Commercial Addition/Alteration PermitComplete
2017T17CM05618Commercial Trade PermitCanceled
2017T17DV03190SIGN VIOLATIONCOMPLIAN
2017T17DV03032EMERGENCYCOMPLIAN
2017T17DV03040EMERGENCYCOMPLIAN
2017T17DV03041EMERGENCYCOMPLIAN
2017T17DV02682SIGN VIOLATIONREFERRED
2017T17CM03553Commercial Addition/Alteration PermitCanceled
2017T17DV01054FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2016T16SA00490Zoning ComplianceComplete
2016T16DV07776RES: MINIMUM HOUSINGNOVERIFY
2016T16DV04682ENVIRONMENTALCOMPLIAN
2015T15DV07239RES: MINIMUM HOUSINGCOMPLIAN
2015T15SA00147Zoning ComplianceComplete
2014T14DV10392RES: MINIMUM HOUSINGNOVERIFY
2014T14DV08759RES: MINIMUM HOUSINGNOVERIFY
2014T14DV08680RES: MINIMUM HOUSINGCOMPLIAN
2013T13OT00228Permanent Sign PermitComplete
2012T12CM07640Commercial Trade PermitComplete
2012T12DV10818RES: MINIMUM HOUSINGCOMPLIAN
2011T11DV06435RES: MINIMUM HOUSINGNOVERIFY
2011T11DV03508RES: MINIMUM HOUSINGNOVERIFY
2011T10CM03062Commercial Trade PermitComplete
2010T10DV07399SIGN VIOLATIONCOMPLIAN
2010T10DV04420RES: MINIMUM HOUSINGNOVERIFY
2010T10PL00683Commercial Trade PermitWithdrawn
2010T10DV02328RES: MINIMUM HOUSINGNOVERIFY
2010T10DV00463RES: MINIMUM HOUSINGCOMPLIAN
2009T09OT02393Annual Portable Sign ComplianceComplete
2009T09DV03918SIGN VIOLATIONCOMPLIAN
2009T09OT01253Annual Portable Sign ComplianceComplete
2008T08OT02797Annual Portable Sign ComplianceCanceled
2008T08DV09449SIGN VIOLATIONCOMPLIAN
2008T08DV04108RES: MINIMUM HOUSINGCOMPLIAN
2008T08DV03122SIGN VIOLATIONCOMPLIAN
2008T08DV02862RES: MINIMUM HOUSINGNOVERIFY
2008T08DV02152MULTIPLE TYPESCOMPLIAN
2007T07CM02715Commercial Trade PermitCanceled
2006T06OT01712Permanent Sign PermitComplete
2003T03EL00487Commercial Trade PermitComplete
2003T03OT00378Permanent Sign PermitComplete
2003T03OT00348Permanent Sign PermitComplete
2003T03VL00236Permanent Sign PermitComplete
2002T02VL01456Permanent Sign PermitComplete
2001T01PL02372Commercial Trade PermitWithdrawn
2001T01EL00490Residential Trade PermitComplete
2000T00VL01521Permanent Sign PermitComplete
2000T00VL01134Permanent Sign PermitComplete
2000T00ME00727Commercial Trade PermitComplete
1999T99ME00118Commercial Trade PermitCanceled
1998T98VL01076Permanent Sign PermitComplete
1998T98ME00419Commercial Trade PermitComplete
1997T97CM01950Commercial Trade PermitCanceled
1997T97ME00039Commercial Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13323093C — 51 City permits on file from 1997 to 2026 and 74 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).