Electrical permit history — 7700 E Speedway Bl

7700 E Speedway Bl, Tucson — built 1980, with 48 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

7700 E Speedway Bl

Built 1980 — 1980s multifamily stock · last permitted panel/service work 2026 (finaled) · 2 open code cases

Parcel
13323093C
Built
1980 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Apartments 100+ Units 3 Or More Story
Parcel size
9.84 acres
Building area
216,953 sq ft (assessor record)
Sewer
Connection on file (2012) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2026 permit was finalized; the permit description states “Provide And Install New Like for Like 200 Amp 42 Space Panel In Place Of Existing Damaged By Water”.

See the property

County aerial photograph centered on 7700 E Speedway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted this year (2026). City inspection record: COT - LCEL - Electrical Final approved 2026-06-01. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0326-00439 — Provide And Install New Like for Like 200 Amp 42 Space Panel In Place Of Existing Damaged By Water
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 pool / spa permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There are 2 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2026. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    Solar equipment was permitted here in 2010 — the permit category covers PV, solar water heating and pool heating alike. If it was PV, there is an existing interconnection and the busbar already carries backfeed, which constrains what else can be added under the 120% rule; a thermal system carries no such constraint. Worth confirming which it is.

Recorded sales (5)

Recorded transfers from the Pima County Assessor — 5 of 5
DatePriceType
2022-07-15$53,900,000Warranty Deed
2017-01-19$14,500,000Warranty Deed
2006-02-28$12,500,000Warranty Deed
2000-12-19$8,760,000Special Warranty Deed
1998-03-31$8,577,072Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-03-27 (TC-COM-0326-00439) — Provide And Install New Like for Like 200 Amp 42 Space Panel In Place Of Existing Damaged By Water.

Permit history (48)

Permit history for this parcel — 8 of 48 records
DateRecordWhatStatusValue
2026-03-27finaledTC-COM-0326-00439City permit recordPool / spaProvide And Install New Like for Like 200 Amp 42 Space Panel In Place Of Existing Damaged By WaterInspections complete
2024-12-13expired 2026-03-04TC-COM-1224-02349City permit recordCommercial BuildingReplacement of entire mechanical water system on property which includes building 1-13.Inspections
2024-11-19expired 2025-12-03TC-COM-1124-02232City permit recordCommercial BuildingUnit is where the fire started.Inspections
2024-11-19expired 2025-12-03TC-COM-1124-02233City permit recordCommercial BuildingFire Damage, Framework, electrical workInspections
2024-10-23expired 2024-11-23SP-NRP-1024-00090City permit recordSimpleUnit 928 Re Connect InspectionExpired
2024-10-23expired 2024-11-23SP-NRP-1024-00091City permit recordElectrical reconnect929 electrical RECONNECTExpired
2024-10-01finaledSP-NRP-1024-00006City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-10-01finaledSP-NRP-1024-00007City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
Show 40 older records
Permit history for this parcel — remaining 40 records
DateRecordWhatStatusValue
2024-10-01finaledSP-NRP-1024-00008City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-10-01finaledSP-NRP-1024-00009City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-10-01finaledSP-NRP-1024-00011City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-10-01finaledSP-NRP-1024-00013City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-10-01finaledSP-NRP-1024-00017City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-10-01finaledSP-NRP-1024-00019City permit recordSimple*Complete - Added to Utility Clearance Report* - - NO POWER TEP SAID WE NEED A RECONNECT PERMIT. - -Complete
2024-09-24expired 2025-03-23TC-RES-0924-05560City permit recordResidential Building - One or Two FamilyVOID: OS - Duplicate/Same scope of work as existing application SP-NRP-1024-00009. This permit will be voided. NO POWER FOR 4 MONTHSVoid
2024-09-24expired 2025-03-23TC-RES-0924-05561City permit recordResidential Building - One or Two FamilyVOID: OS - Duplicate/Same scope of work as existing application SP-NRP-1024-00011 . This permit will be voided. NO POWER FOR 4 MONTHSVoid
2024-09-23expired 2025-03-22TC-RES-0924-05504City permit recordResidential Building - One or Two FamilyUnit # 208 needs inspection due to no power for 3 months.Void
2024-09-23expired 2025-03-22TC-RES-0924-05505City permit recordResidential Building - One or Two FamilyVOID: OS - Duplicate/Same scope of work as existing application SP-NRP-1024-00008. This permit will be voided. PER TEP CLEARANCE REQUIRED AFTER 90 DAYS OF NO POWER TO VACANT UNIT.Void
2024-09-23finaledTC-RES-0924-05506City permit recordResidential Building - One or Two FamilyPER TEP CLEARANCE REQUIRED AFTER 90 DAYS OF NO POWER TO VACANT UNIT. # 302Complete
2024-09-23finaledTC-RES-0924-05507City permit recordResidential Building - One or Two FamilyPER TEP CLEARANCE REQUIRED AFTER 90 DAYS OF NO POWER TO VACANT UNIT. 805Complete
2024-09-23expired 2025-03-22TC-RES-0924-05508City permit recordResidential Building - One or Two FamilyVOID: OS - Duplicate/Same scope of work as existing application SP-NRP-1024-00007. This permit will be voided. PER TEP CLEARANCE REQUIRED AFTER 90 DAYS OF NO POWER TO VACANT UNIT. # 813Void
2024-09-23expired 2025-03-22TC-RES-0924-05509City permit recordResidential Building - One or Two FamilyVOID: OS - Duplicate/Same scope of work as existing application SP-NRP-1024-00006. This permit will be voided. PER TEP CLEARANCE REQUIRED AFTER 90 DAYS OF NO POWER TO VACANT UNIT. 1114Void
2024-09-23expired 2025-03-22TC-RES-0924-05523City permit recordResidential Building - One or Two FamilyVOID: OS - Duplicate/Same scope of work as existing application SP-NRP-1024-00017. This permit will be voided. no power for over 6 monthsVoid
2024-06-21expired 2024-12-18TC-COM-0624-01186City permit recordCommercial BuildingVOIDED DUPLICATE PERMIT Emergency Inspection of repair and pressure test on existing gas line per SW GASVoid
2024-06-20finaledTC-COM-0624-01181City permit recordCommercial BuildingGas main breakComplete
2020-07-30finaledT20CM04881City permit recordCommercial BuildingREPAIR REPL BBQ GAS RISER restoring gas services to this 400 person apartment complexComplete
2018-01-02expired 2018-08-27T18CM00005City permit recordCOMBOT17DV06776 T17DV04657 REPL ROOF DECKING, BLKING, ELECTRIC FIRE DAMAGE REPAIRExpired
2017-12-28T17CM09522City permit recordCOMBOT17DV04657 T17DV06776 REPAIR WIRING IN BATHROOM FROM FAN FIREWithdrwn
2017-10-02finaledT17CM07476City permit recordCOMBOREPLACE HOT WATER LINESFinal
2017-08-28finaledT17CM06583City permit recordCOMBOCOMMERCIAL TI: FIRE DAMAGE REPAIR; T17DV03032;304,3041 - RHOLLAND 520-419-5354Final
2017-07-24expired 2018-02-25T17CM05618City permit recordCOMBO(T17DV03032,3040,3041) FIRE DAMAGE REPAIRExpired
2017-05-05expired 2017-12-05T17CM03553City permit recordCOMBO(T17DV01054) FIRE DAMAGE REPAIRExpired
2013-02-22finaledT13OT00228City permit recordSIGNCHANGE OF COPY 3/1/13Final
2012-12-04finaledT12CM07640City permit recordCOMBOREPLACE:SEWER LINE:APT COMPLEXFinal
2010-11-01finaledT10CM03062City permit recordSolar PVINSTALL:SOLAR WATER HEATERFinal
2010-04-27T10PL00683City permit recordPLUMBREPAIR:GAS STUBWithdrwn
2009-11-09finaledT09OT02393City permit recordSIGN17448Final
2009-06-18finaledT09OT01253City permit recordSIGN16835Final
2008-11-25expired 2009-02-23T08OT02797City permit recordSIGN15968Expired
2007-06-26expired 2009-05-24T07CM02715City permit recordFence / wallREPLACE HOT WATER BOILER:DRYWALLClosed
2006-06-28finaledT06OT01712City permit recordSIGN11419Final
2003-03-18finaledT03EL00487City permit recordELECTELECTRIC:RECONNECTFinal
2003-03-11finaledT03OT00378City permit recordSIGNSIGN:5160Final
2003-03-06finaledT03OT00348City permit recordSIGNSIGN:5138Final
2001-11-28T01PL02372City permit recordPLUMBWATER LINE:REPLAIR (APA) BWOPWithdrwn
2001-03-01finaledT01EL00490City permit recordELECTELECTRIC SERVICE:RECONNECTFinal
2000-06-26finaledT00ME00727City permit recordMECHPRESSURE VESSEL CERTIFICATE:TUC-24492-24493Final
1999-01-27expired 2009-05-24T99ME00118City permit recordMECHBOILER:REPLACE TUBESClosed

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (100)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 100 records
DateRecordWhatStatus
2026-07-08CE-VIO0726-02851Code enforcement caseCode enforcement caseClosed - unfounded
2026-07-08CE-VIO0726-02849Code enforcement caseCode enforcement caseActive
2026-05-19CE-VIO0526-02192Code enforcement caseCode enforcement caseReferred
2026-05-19CE-VIO0526-02191Code enforcement caseCode enforcement caseReceived
2026-03-06CE-VIO0326-01111Code enforcement caseCode enforcement caseClosed - resolved
2026-02-18CE-VIO0226-00862Code enforcement caseCode enforcement caseClosed - resolved
2025-09-24CE-VIO0925-04220Code enforcement caseCode enforcement caseClosed - resolved
2025-09-23CE-VIO0925-04202Code enforcement caseCode enforcement caseClosed - unfounded

92 older records are not shown here. — each links to its official file.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13323093C — 48 permits on file from 1999 to 2026 (9 simple, 9 residential building - one or two family, 7 combo, 7 sign) and 100 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).