Electrical permit history — 7163 E Broadway Bl

7163 E Broadway Bl, Tucson — built 1981, with 88 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

7163 E Broadway Bl

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1981 — 1980s commercial stock · 88 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 state licensed facility operational fire permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 state licensed facility operational fire permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2012 (14 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T11BU01673 — RELOCATE 53 AND ADD 18 FIRE SPRINKLERS.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2018. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2018. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 124,230 sq ft (county building-footprint layer; 2 neighbouring structures crossing the lot line excluded)
Usable for solar, planning estimate
≈ 87,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 960 kW — roughly 2,400 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,580,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$126,000–$205,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Irvington and Houghton”, is about 3.8 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
133225010
Year constructed
1981 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Cmmnty Shp Ctr Open Air Non-Qualifying
Building area
32,475 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 88 building permits for this parcel dated between 1998 and 2025. By category the work is trade permit (28), permanent sign (20), addition / alteration (15) and fire automatic extinguishing system (11). 65 of them carry a final inspection; the other 23 were issued, expired or are still open, which is not the same as work completed. There are 2 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 133225010. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85710 · Commercial & industrial reports · Homes in 85710 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E BROADWAY BL hold 5,314 City permits on record, 1,040 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (90 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025TF-FOP-0725-00969State Licensed Facility Operational Fire PermitComplete
2024TF-FOP-0624-00737State Licensed Facility Operational Fire PermitComplete
2023TF-FOP-0623-01112State Licensed Facility Operational Fire PermitComplete
2023TC-UTL-1222-00020Cell Tower Building PermitIssued
2022T22FO00418State Licensed Facility Operational Fire PermitComplete
2021T21SE00020Mayor Council Special ExceptionApproved
2020T20OT00769Permanent Sign PermitExpired
2020T20FO00361State Licensed Facility Operational Fire PermitComplete
2019T19CM03293Commercial Trade PermitCanceled
2019T19OT00621Permanent Sign PermitComplete
2018T18CM02975Commercial Trade PermitComplete
2018T18CM02425Commercial Trade PermitComplete
2018T18SE00007Mayor Council Special ExceptionApproved
2017T15CM07550Commercial Trade PermitComplete
2016T15OT01580Permanent Sign PermitComplete
2016T15BU01459Commercial Trade PermitComplete
2015T15CM07277Commercial Trade PermitComplete
2015T15SE00061Mayor Council Special ExceptionApproved
2013T13CM07583Commercial Addition/Alteration PermitComplete
2013T13CM05803Commercial Trade PermitComplete
2012T12BU01221Commercial Trade PermitComplete
2012T11BU01673Fire Automatic Extinguishing System PermitComplete
2011T11BU01585Commercial Trade PermitComplete
2011T11CM02486Commercial Addition/Alteration PermitComplete
2011T11CM02541Commercial Addition/Alteration PermitComplete
2011T11OT01767Permanent Sign PermitComplete
2011T11SE00025Mayor Council Special ExceptionApproved
2011T11PL00940Commercial Trade PermitComplete
2011T11PL00384Commercial Trade PermitComplete
2011T11DV00975WORK WITHOUT PERMITS-COMMERCLCOMPLIAN
2010T10OT00474Permanent Sign PermitCanceled
2010T10OT00379Commercial Addition/Alteration PermitCanceled
2009T09SA00183Zoning ComplianceComplete
2009T09SA00154Zoning ComplianceComplete
2009T09BU00719Fire Automatic Extinguishing System PermitComplete
2009T09SA00122Zoning ComplianceComplete
2009T09OT00840Permanent Sign PermitComplete
2008T08DV02906WEEDSCOMPLIAN
2008T08SE00003Zoning Examiner Special ExceptionCanceled
2007T07CM04726Commercial Addition/Alteration PermitWithdrawn
2007T07BU00721Fire Automatic Extinguishing System PermitComplete
2007T07OT00680Permanent Sign PermitComplete
2007T07CM01091Commercial Addition/Alteration PermitComplete
2007T07BU00160Commercial Addition/Alteration PermitComplete
2007T07DV00072Permanent Sign PermitComplete
2006T06OT03227Permanent Sign PermitComplete
2006T06CM05516Commercial Addition/Alteration PermitComplete
2006T06BU02783Fire Automatic Extinguishing System PermitCanceled
2006T06BU02666Commercial Addition/Alteration PermitComplete
2006T06BU02377Fire Automatic Extinguishing System PermitCanceled
2006T06BU02187Fire Automatic Extinguishing System PermitComplete
2006T06OT02051Permanent Sign PermitCanceled
2006T06OT01994Permanent Sign PermitComplete
2006T06OT01995Permanent Sign PermitComplete
2006T06CM03595Commercial Addition/Alteration PermitComplete
2006T06CM02478Commercial Addition/Alteration PermitWithdrawn
2006T06BU01142Fire Automatic Extinguishing System PermitCanceled
2006T06EL00919Commercial Trade PermitComplete
2006T06BU00044Fire Automatic Extinguishing System PermitComplete
2005T05EL02386Commercial Trade PermitComplete
2005T05OT02611Permanent Sign PermitCanceled
2005T05OT02610Permanent Sign PermitComplete
2005T05BU02028Fire Automatic Extinguishing System PermitComplete
2005T05BU01936Fire Automatic Extinguishing System PermitComplete
2005T05BU01947Fire Automatic Extinguishing System PermitComplete
2005T05EL01523Commercial Trade PermitCanceled
2005T05CM02881Commercial Addition/Alteration PermitComplete
2005T05EL01491Commercial Trade PermitComplete
2005T05OT00705Permanent Sign PermitComplete
2005T05OT00570Permanent Sign PermitComplete
2005T05OT00556Permanent Sign PermitComplete
2005T05OT00124Commercial Addition/Alteration PermitComplete
2005T05OT00388Permanent Sign PermitComplete
2005T05EL00110Commercial Trade PermitComplete
2004T04OT02375Permanent Sign PermitComplete
2004T04OT02374Permanent Sign PermitComplete
2004T04EL01805Commercial Trade PermitComplete
2004T04EL00231Commercial Trade PermitCanceled
2003T03EL00128Commercial Trade PermitComplete
2002T02EL01743Commercial Trade PermitCanceled
2002T02EL01742Commercial Trade PermitComplete
2001T01EL01869Commercial Trade PermitComplete
2000T00EL00325Commercial Trade PermitComplete
1998T98CM04960Commercial Addition/Alteration PermitWithdrawn
1998T98PL02177Commercial Trade PermitComplete
1998T98PL02176Commercial Trade PermitCanceled
1998T98EL01967Commercial Trade PermitComplete
1998T98EL01137Commercial Trade PermitComplete
1998T98BU01113Commercial Addition/Alteration PermitComplete
1998T98EL00718Commercial Trade PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 133225010 — 88 City permits on file from 1998 to 2025 and 2 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.