Electrical permit history — 6901 E Broadway Bl
6901 E Broadway Bl, Tucson — built 1972, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
6901 E Broadway Bl
Built 1972 — 1970s multifamily stock · last permitted panel/service work 2018 (finaled) · 1 open code case
Permanent link: Electrical permit history for 6901 E Broadway Bl (aztucsonelectricalsolutions.com/property/13322432c/6901-e-broadway-bl-tucson-az-85710) · Public records last checked 2026-08-16
- Parcel
- 13322432C
- Built
- 1972 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Apartments 100+ Units 2 Story
- Parcel size
- 4.56 acres
- Building area
- 87,874 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2018 permit was finalized; the permit description states “3 LF INSTALL NEW 1-1/2 COPPER SERVICE LINE ON HTE WEST SIDE OF THE PROPERTY IN THE ALLEY IN ASPHALT.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2018 (8 years ago). City inspection record: last recorded inspection 2018-10-22; no approved final is shown. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T18RW03749 — 3 LF INSTALL NEW 1-1/2 COPPER SERVICE LINE ON HTE WEST SIDE OF THE PROPERTY IN THE ALLEY IN ASPHALT.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2012 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2024. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2021-12-08 | $10,560,000 | Warranty Deed |
| 2007-02-15 | $5,900,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-05-05 (TC-COM-0526-00662) — A/C Change Out, Like for Like, 2.0 Ton UNIT 243.
Permit history (19)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-05-05 | TC-COM-0526-00662City permit record | Commercial BuildingA/C Change Out, Like for Like, 2.0 Ton UNIT 243 | Needs resubmittal | |
| 2026-05-05 | TC-COM-0526-00663City permit record | Commercial BuildingA/C Change Out, Like for Like, 2.0 Ton UNIT 137 | Needs resubmittal | |
| 2025-09-28 | TC-COM-0925-01776City permit record | Fence / wallCODE VIOLATION FOR MULTIPLE WALLS, GATES, LANDSCAPING, ELECTRICAL | Expired | |
| 2025-07-11finaled | TC-COM-0725-01344City permit record | Commercial BuildingCONNECT POWER TO EXISTING UNIT | Complete | |
| 2025-07-10expired 2026-01-13 | TC-COM-0725-01337City permit record | Commercial BuildingReconnect existing power to unit | Inspections | |
| 2025-07-09expired 2025-08-08 | SP-NRP-0725-00354City permit record | Addition / alteration*VOID - The City of Tucson has not approved your Reconnect Only Inspection. Our records indicate multiple code violations at this location. To proceed, you must apply for an Addition/Alteration permit. electric was disconnected for more than 6 months - - | Denied | |
| 2025-02-19expired 2025-12-15 | TC-COM-0225-00357City permit record | Pool / spaInterior renovation of existing space turning it into a sales/leasing office | Inspections | |
| 2024-12-10expired 2025-10-25 | TC-COM-1224-02330City permit record | Pool / spaRemove and raise an existing roof. 90 sq. ft. over a hallway of unheated space between two buildings | Issued |
Show 11 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-09-25 | TC-DMO-0924-00215City permit record | Demolition*VOID: YL-Unable to process, according to the documents submitted and the description of work provided this is the wrong permit type. Submit a new application under Commercial Interior Only Demolition Permit. This permit will be voided as it is not the correct permit type. For questions: Building_Official@tucsonaz.gov* -Selective, interior demolition of leasing office. SOW includes: Removal of all interior walls and doors, floor coverings, drop ceiling and grid, plumbing fixtures, HVAC duct and registers, and DWV piping. | Void | |
| 2024-07-29finaled | TC-RES-0724-04395City permit record | Electrical reconnectElectrical Reconnect for office space | Complete | |
| 2023-04-11expired 2023-10-08 | TS-PRM-0423-00270City permit record | Sign - Permanent**VOID** BP- DUPLICATE Build New Monument over existing sign base attach new sign | Void | |
| 2023-02-13finaled | TS-PRM-0223-00182City permit record | Sign - PermanentFab and Install Illuminated Box Sign, Rebuild new Monument Sign (36.7 sqf.t monument sign area on replacement cabinet / same support - reviewed as new sign for sign area/ electrical) | Complete | |
| 2023-01-09expired 2024-01-05 | TC-COM-0123-00432City permit record | Pool / spaRemodel of existing leasing office, conversion of existing community room to a fitness center, and reconstruction of existing shade structure. Leasing office scope includes demolition of existing laundry room and restrooms and reconfiguration of the space and construction f one new restroom, addition of new exterior windows, and new lighting and mechanical distribution throughout. Fitness Center scope includes demolition of existing kitchenette and stair, replacement of existing windows and new lighting and mechanical distributing throughout. Shade structure scope includes demolition of existing shade structure and construction of new steel shade structure in its place. | Expired | |
| 2020-01-21finaled | T20CM00433City permit record | COMBOWATER MAIN LINE REPL | Final | |
| 2018-08-21finaled | T18RW03749City permit record | ROW3 LF INSTALL NEW 1-1/2 COPPER SERVICE LINE ON HTE WEST SIDE OF THE PROPERTY IN THE ALLEY IN ASPHALT. | Final | |
| 2017-11-02expired 2018-06-06 | T17CM08221City permit record | COMBOFIRE DAMAGE REPL ROOF JOIST | Expired | |
| 2017-10-27finaled | T17CM08082City permit record | Pool / spaREPAIR/REPL GAS LINE TO POOL & SPA HEATER | Final | |
| 2012-05-09finaled | T12CM02583City permit record | COMBOFIRE RESTORATION, SHEETROCK, INSULATION AND ELECTRICAL - COMM-REPAIR LIKE FOR LIKE | Final | |
| 2007-11-07finaled | T07OT02529City permit record | SIGN13985 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (20)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-12-30 | CE-VIO1225-05567Code enforcement case | Code enforcement case | Closed - resolved |
| 2025-12-23 | CE-VIO1225-05479Code enforcement case | Code enforcement case | Referred |
| 2025-06-23 | CE-VIO0625-02698Code enforcement case | Work without permit | Citation |
| 2025-01-06 | CE-VIO0125-00044Code enforcement case | Code enforcement case | Closed - resolved |
| 2024-11-27 | CE-VIO1124-04749Code enforcement case | Work without permit | Referred |
| 2024-11-01 | CE-VIO1124-04383Code enforcement case | Work without permit | Closed - resolved |
| 2023-09-19 | TR-NOV0923-00025Code enforcement case | Code enforcement case | Referred |
| 2023-08-02 | CE-VIO0823-04904Code enforcement case | Work without permit | Closed - resolved |
Show 12 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2023-05-10 | CE-VIO0523-03429Code enforcement case | Work without permit | Closed - unfounded |
| 2017-10-18 | T17DV05403Code enforcement case | Fire | Complian |
| 2015-08-04 | T15DV05737Code enforcement case | Sign | Complian |
| 2012-04-09 | T12DV02711Code enforcement case | Fire | Complian |
| 2009-12-14finaled | T09FR03762Code enforcement case | Code enforcement case | Complete |
| 2009-10-07 | T09DV05789Code enforcement case | Vegetation | Complian |
| 2007-10-17finaled | T07FR02082Code enforcement case | Code enforcement case | Complete |
| 2006-04-11 | T06DV00401Code enforcement case | Fire | Complian |
| 2005-08-31finaled | T05FR01372Code enforcement case | Code enforcement case | Complete |
| 2005-08-24finaled | T05FR01339Code enforcement case | Code enforcement case | Complete |
| 2005-08-24finaled | T05FR01340Code enforcement case | Code enforcement case | Complete |
| 2005-02-10finaled | T05FR00234Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 13322432C — 19 permits on file from 2007 to 2026 (4 commercial building, 4 pool / spa, 3 combo, 2 sign - permanent) and 20 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.