Electrical permit history — 554 N Wilmot Rd

554 N Wilmot Rd, Tucson — built 1980, with 224 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

554 N Wilmot Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1980 — 1980s commercial stock · last permitted panel/service work 2024 (finaled) · HVAC 2000 (finaled) · 1 open code case

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2024 (2 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0924-01830 — New Electrical Service - okay to apply for second permit at this location per JG
  • Heating, cooling & mechanicalLikely dueLast permitted 2000 (26 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T00CM04162 — REPLACE:CT EQUIPMENT/HVAC/ELECTRIC
  • Fire alarm & life safetyFinaled permit foundA newer 2025 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “FIRE ALARM ELEVATOR UPGRADE.”. Last permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0425-00329 — modify sprinklers per nfpa.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2024 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    A trade permit was pulled in 2024. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 270,293 sq ft (county building-footprint layer, 7 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 189,200 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 2,080 kW — roughly 5,200 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 3,420,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$274,000–$445,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 3.1 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
133170630
Year constructed
1980 (assessor record)
Permitting authority
Tucson
Zoning
PAD-13
Property type
Hospital
Building area
1,123,935 sq ft
Service on record
City records show the 2024 permit was finalized; the permit description states “New Electrical Service - okay to apply for second permit at this location per JG”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 224 building permits for this parcel dated between 1997 and 2026. By category the work is fire automatic extinguishing system (54), addition / alteration (45), trade permit (39) and registered facility annual (22). 169 of them carry a final inspection; the other 55 were issued, expired or are still open, which is not the same as work completed. There are 2 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 133170630. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85711 · Commercial & industrial reports · Homes in 85711 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N WILMOT RD hold 1,672 City permits on record, 269 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (226 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-0925-01621Commercial Addition/Alteration PermitComplete
2026TC-REG-0126-00002Registered Facility Annual PermitIssued
2026TC-COM-0325-00619Commercial Addition/Alteration PermitInspections
2025TD-DEV-0925-00250Development PackageIssued
2025TF-FCP-0825-00652Fire Automatic Extinguishing System PermitWithdrawn
2025TC-COM-0724-01351Commercial Addition/Alteration PermitComplete
2025TF-FCP-0725-00531Fire Alarm System PermitExpired
2025TP-PRE-0725-00139Pre-Application ConferenceComplete
2025TF-FCP-0425-00329Fire Automatic Extinguishing System PermitComplete
2025TC-COM-0125-00166Commercial Addition/Alteration PermitComplete
2025TC-COM-0325-00620Commercial Addition/Alteration PermitWithdrawn
2025TC-COM-0225-00342Commercial Addition/Alteration PermitApproved
2025TC-COM-1024-02028Commercial Addition/Alteration PermitComplete
2025TF-FOP-1223-01834General Operational Fire PermitComplete
2025TF-FOP-0224-00149State Licensed Facility Operational Fire PermitComplete
2025TF-FOP-1223-01835General Operational Fire PermitComplete
2024TC-COM-0924-01830Commercial Trade PermitComplete
2024TF-FCP-0724-00591Fire Alarm System PermitComplete
2024TF-FCP-0724-00540Fire Automatic Extinguishing System PermitComplete
2023TF-FCP-0823-00954Fire Automatic Extinguishing System PermitComplete
2023TF-FCP-0723-00828Other IFC Construction PermitIssued
2023TC-REG-0523-00010Registered Facility Annual PermitIssued
2023TF-FOP-0223-00437State Licensed Facility Operational Fire PermitComplete
2023TF-FOP-1222-00197General Operational Fire PermitComplete
2023TF-FOP-1222-00252General Operational Fire PermitComplete
2023TF-FCP-0223-00400Fire Automatic Extinguishing System PermitExpired
2022T22OT00216Registered Facility Annual PermitIssued
2022T22DV00304Code enforcement caseActive
2021T21FC00691Fire Automatic Extinguishing System PermitComplete
2021T20CM06314Commercial Addition/Alteration PermitComplete
2021T21FO00377State Licensed Facility Operational Fire PermitComplete
2021T21FO00379State Licensed Facility Operational Fire PermitComplete
2021T21FC00406Fire Alarm System PermitComplete
2020T20FO00378State Licensed Facility Operational Fire PermitComplete
2020T20FC00623Fire Alarm System PermitComplete
2020T20FO00379State Licensed Facility Operational Fire PermitComplete
2020T20OT00439Registered Facility Annual PermitExpired
2020T19FC01064Fire Alarm System PermitExpired
2019T19FO00634State Licensed Facility Operational Fire PermitComplete
2019T19FO00635State Licensed Facility Operational Fire PermitComplete
2019T19DV05230SIGN VIOLATIONNOVERIFY
2019T19OT00179Registered Facility Annual PermitExpired
2018T18FO00985General Operational Fire PermitComplete
2018T18FO00986State Licensed Facility Operational Fire PermitComplete
2018T18FO00987General Operational Fire PermitComplete
2018T18FO00988General Operational Fire PermitComplete
2018T18FO00990General Operational Fire PermitComplete
2018T18FO00982General Operational Fire PermitComplete
2018T18FO00983General Operational Fire PermitComplete
2018T18FO00984General Operational Fire PermitComplete
2018T18FO00989General Operational Fire PermitComplete
2018T18FC00839Fire Alarm System PermitComplete
2018T18FC00690Fire Automatic Extinguishing System PermitExpired
2018T18FC00685Fire Automatic Extinguishing System PermitWithdrawn
2018T18FO00180Fire Code AppealComplete
2018T18FO00471State Licensed Facility Operational Fire PermitComplete
2018T18FC00200Fire Automatic Extinguishing System PermitComplete
2018T18FC00260Fire Alarm System PermitExpired
2018T18FC00170Fire Alarm System PermitComplete
2018T18OT00027Permanent Sign PermitExpired
2018T18OT00115Registered Facility Annual PermitExpired
2018T17OT01153Permanent Sign PermitExpired
2017T17CM03268Commercial Addition/Alteration PermitComplete
2017T17FC00802Fire Automatic Extinguishing System PermitComplete
2017T17FC00774Fire Automatic Extinguishing System PermitComplete
2017T17CM04859Commercial Addition/Alteration PermitComplete
2017T17CM03070Commercial Addition/Alteration PermitCanceled
2017T17FC00182Fire Automatic Extinguishing System PermitCanceled
2017T17FC00221Fire Automatic Extinguishing System PermitComplete
2017T17FC00181Fire Automatic Extinguishing System PermitExpired
2017T17OT00091Registered Facility Annual PermitExpired
2016T16BU01075Fire Automatic Extinguishing System PermitComplete
2015T15BU01151Fire Automatic Extinguishing System PermitComplete
2015T15CM03361Commercial Trade PermitComplete
2015T15OT00351Registered Facility Annual PermitCanceled
2015T15SA00004Zoning ComplianceComplete
2014T14OT00614Permanent Sign PermitComplete
2014T14BU00766Commercial Trade PermitComplete
2014T14BU00402Fire Automatic Extinguishing System PermitComplete
2014T14OT00168Registered Facility Annual PermitComplete
2014T14OT00169Registered Facility Annual PermitCanceled
2014T14CM00706Commercial Addition/Alteration PermitWithdrawn
2013T07OT02452Floodplain Use PermitCanceled
2013T13OT00571Registered Facility Annual PermitComplete
2013T13BU00296Commercial Trade PermitComplete
2013T13BU00286Fire Automatic Extinguishing System PermitCanceled
2013T13OT00271Permanent Sign PermitComplete
2013T13BU00021Fire Automatic Extinguishing System PermitComplete
2013T12CM06870Commercial Addition/Alteration PermitCanceled
2013T13OT00026Registered Facility Annual PermitComplete
2012T12CM04879Commercial Addition/Alteration PermitCanceled
2012DP12-0124Development PackageComplete
2012T12BU00849Fire Automatic Extinguishing System PermitCanceled
2012T12OT00336Registered Facility Annual PermitComplete
2011T11OT00552Registered Facility Annual PermitComplete
2011T11BU00249Fire Automatic Extinguishing System PermitComplete
2010T10BU01762Fire Automatic Extinguishing System PermitComplete
2010T10BU01009Fire Automatic Extinguishing System PermitComplete
2010T10OT01287Permanent Sign PermitComplete
2010T10OT01125Permanent Sign PermitComplete
2010T10OT00268Registered Facility Annual PermitComplete
2009T09BU01446Fire Automatic Extinguishing System PermitComplete
2009T09BU00271Commercial Trade PermitCanceled
2009T09OT01464Permanent Sign PermitComplete
2009T09OT01288Permanent Sign PermitComplete
2009T09OT00429Registered Facility Annual PermitComplete
2009T09OT00462Permanent Sign PermitCanceled
2009T09BU00247Commercial Trade PermitComplete
2009T09OT00259Permanent Sign PermitComplete
2008T08BU01683Fire Automatic Extinguishing System PermitComplete
2008T08BU01710Commercial Addition/Alteration PermitComplete
2008T08BU01451Commercial Addition/Alteration PermitComplete
2008T08CM00344Commercial Addition/Alteration PermitComplete
2008T08OT00776Registered Facility Annual PermitCanceled
2008T08PL00674Commercial Trade PermitComplete
2008T08OT00529Permanent Sign PermitComplete
2008T08BU00667Fire Automatic Extinguishing System PermitComplete
2008T08CM00246Commercial Trade PermitWithdrawn
2007T07CM03017Commercial Addition/Alteration PermitComplete
2007D07-0007Development PackageComplete
2007T07BU02161Fire Automatic Extinguishing System PermitComplete
2007T07BU01681GradingComplete
2007T07BU02187Commercial Addition/Alteration PermitComplete
2007T07BU01626Commercial Trade PermitComplete
2007T07BU00616GradingComplete
2007T07CM01426Commercial Trade PermitCanceled
2007T06CM06197Commercial Addition/Alteration PermitComplete
2007T07OT00517Registered Facility Annual PermitCanceled
2007T06CM03783Commercial New Building PermitComplete
2007T07BU00139Fire Automatic Extinguishing System PermitComplete
2007T06CM01872Commercial Addition/Alteration PermitComplete
2007T07OT00087Permanent Sign PermitComplete
2006D06-0016Development PackageComplete
2006T06CM06196Commercial Trade PermitWithdrawn
2006T06BU01160Commercial Trade PermitComplete
2006T05BU03025GradingComplete
2006T06CM05174Commercial Trade PermitComplete
2006D06-0008Development PackageComplete
2006T06BU02454Commercial Trade PermitComplete
2006T06BU01863Fire Automatic Extinguishing System PermitComplete
2006T06BU02074Fire Automatic Extinguishing System PermitComplete
2006T06CM03198Commercial Addition/Alteration PermitComplete
2006T06BU01393Fire Automatic Extinguishing System PermitComplete
2006T05CM05115Commercial Trade PermitComplete
2006T06OT00705Registered Facility Annual PermitCanceled
2006T06BU00330GradingComplete
2006T06PL00347Commercial Trade PermitComplete
2006T06CM00845Commercial Trade PermitWithdrawn
2006C9-05-20 RezoningEffectuated
2006T06BU00334Commercial DemolitionComplete
2006T06BU00283Commercial DemolitionComplete
2006T05BU02893Commercial Trade PermitComplete
2005T05BU03023GradingWithdrawn
2005T05CM06458Commercial Trade PermitWithdrawn
2005T05BU02087Fire Automatic Extinguishing System PermitComplete
2005T05CM02406Commercial Addition/Alteration PermitComplete
2005T05OT01229Registered Facility Annual PermitCanceled
2005T05BU00589Fire Automatic Extinguishing System PermitComplete
2005T04CM05004Commercial Addition/Alteration PermitComplete
2005T05CM00083Commercial Addition/Alteration PermitComplete
2004T04BU02673Fire Automatic Extinguishing System PermitComplete
2004T04BU02390Fire Automatic Extinguishing System PermitComplete
2004T04CM03674Commercial Addition/Alteration PermitComplete
2004T04BU02075Commercial Trade PermitComplete
2004T04BU02147Fire Automatic Extinguishing System PermitComplete
2004T04BU01863Fire Automatic Extinguishing System PermitComplete
2004T04OT00053Development PackageComplete
2004T04CM00658Commercial Addition/Alteration PermitComplete
2004T04PL00842Commercial Trade PermitWithdrawn
2004T04CM01251Commercial Addition/Alteration PermitComplete
2004T04CM01161Commercial Addition/Alteration PermitWithdrawn
2004T04CM00771Commercial Addition/Alteration PermitComplete
2004T04CM00931Commercial Addition/Alteration PermitWithdrawn
2004T04CM00930Commercial Addition/Alteration PermitWithdrawn
2004T04CM00691Commercial Addition/Alteration PermitComplete
2004T04BU00368Commercial DemolitionComplete
2004T04BU00287Fire Automatic Extinguishing System PermitComplete
2004T04CM00571Commercial Addition/Alteration PermitComplete
2004T04CM00515Commercial Addition/Alteration PermitComplete
2004T04CM00461Commercial Addition/Alteration PermitComplete
2004T04BU00061GradingWithdrawn
2003T03BU01983Fire Automatic Extinguishing System PermitComplete
2003T03BU01565Fire Automatic Extinguishing System PermitComplete
2003T03CM02712Commercial Addition/Alteration PermitComplete
2003T02CM05280Commercial Trade PermitComplete
2003T03CM00919Commercial Addition/Alteration PermitWithdrawn
2002T02BU02983Fire Automatic Extinguishing System PermitComplete
2002T02BU02898Fire Automatic Extinguishing System PermitComplete
2002T02BU02885Fire Automatic Extinguishing System PermitComplete
2002T02BU02784Fire Automatic Extinguishing System PermitComplete
2002T02BU02861Fire Automatic Extinguishing System PermitComplete
2002T02BU02860Fire Automatic Extinguishing System PermitComplete
2002T02BU01467Fire Automatic Extinguishing System PermitComplete
2002T01CM00001Commercial Trade PermitComplete
2001T01BU02027Fire Automatic Extinguishing System PermitCanceled
2001T01CM01060Commercial Addition/Alteration PermitComplete
2000T00CM05635Commercial Trade PermitComplete
2000T00CM04878Commercial Addition/Alteration PermitCanceled
2000T00ME01196Commercial Trade PermitComplete
2000T00ME01195Commercial Trade PermitComplete
2000T00BU03009Fire Automatic Extinguishing System PermitComplete
2000T00BU02697Commercial Trade PermitWithdrawn
2000T00CM04162Commercial Addition/Alteration PermitComplete
2000T00ME00713Commercial Trade PermitComplete
2000T00ME00647Commercial Trade PermitComplete
2000T00ME00648Commercial Trade PermitComplete
2000T00ME00637Commercial Trade PermitComplete
2000T00ME00324Commercial Trade PermitComplete
2000T00BU00261Fire Automatic Extinguishing System PermitComplete
1999T99CM05379Commercial Addition/Alteration PermitComplete
1999T99CM05587Commercial Addition/Alteration PermitComplete
1999T99ME01045Commercial Trade PermitComplete
1999T99ME00715Commercial Trade PermitComplete
1999T99EL00973Commercial Trade PermitComplete
1999T99CM01060Commercial Addition/Alteration PermitComplete
1999T99ME00284Commercial Trade PermitComplete
1998T98OT00337Registered Facility Annual PermitComplete
1998T98CM04047Commercial Addition/Alteration PermitComplete
1998T98BU01769Fire Automatic Extinguishing System PermitComplete
1998T98BU01607Fire Automatic Extinguishing System PermitComplete
1998T98ME00353Commercial Trade PermitComplete
1998T98ME00323Commercial Trade PermitComplete
1998T98CM00465Commercial Trade PermitWithdrawn
1998T98BU00374Fire Automatic Extinguishing System PermitComplete
1997T97OT00275Registered Facility Annual PermitComplete
1997T97BU01187Fire Automatic Extinguishing System PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 133170630 — 224 City permits on file from 1997 to 2026 and 2 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.