Electrical permit history — 2130 N Wilmot Rd

2130 N Wilmot Rd, Tucson — built 1977, with 44 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2130 N Wilmot Rd

Built 1977 — 1970s commercial stock · last permitted panel/service work 2019 (finaled); a newer 2020 permit is expired without a final

Parcel
13316027E
Built
1977 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Warehouse W/ Office/ Retail
Parcel size
2.88 acres
Building area
67,200 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2019 permit was finalized; the permit description states “REPLACE 100 AMP SERVICE DISCONNECT”.

See the property

County aerial photograph centered on 2130 N Wilmot Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentA newer 2020 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “REPLACE 200 AMP 3 PHASE PANEL”. Last permitted 2019 (7 years ago). City inspection record: ELECTRIC - FINAL approved 2020-01-03. Contractor of record: DUFFY ELECTRICAL INC *APA*. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T19CM09050 — REPLACE 100 AMP SERVICE DISCONNECT
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2010 fence / wall permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyLikely dueLast permitted 2003 (23 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T03BU01115 — FIRE SPKR:ADD 2
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

  • Worth confirming

    There is an electrical reconnect permit from 2021. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2023-03-20 (TC-COM-0323-00832) — Plumbing Backflow needs to be replaced in the front of the suite.

Permit history (44)

Permit history for this parcel — 8 of 44 records
DateRecordWhatStatusValue
2023-03-20expired 2023-09-16TC-COM-0323-00832City permit recordCommercial BuildingPlumbing Backflow needs to be replaced in the front of the suiteExpired
2021-03-22expired 2021-09-21T21OT00213City permit recordFence / wall4= CofC illum wall signsIssued
2021-01-06finaledT21CM00118City permit recordElectrical reconnectElectrical reconnectFinal
2020-08-19expired 2021-02-28T20CM05366City permit recordCommercial BuildingREPLACE 200 AMP 3 PHASE PANELExpired
2019-12-10finaledT19CM09050City permit recordCOMBOREPLACE 100 AMP SERVICE DISCONNECTFinal
2018-10-22finaledT18CM08408City permit recordElectrical reconnectELECTRICAL RECONNECTFinal
2018-03-22finaledT18CM02196City permit recordCOMBOREPLACE ELECTRIC METER BOX: LIKE FOR LIKE 300 AMPFinal
2016-12-15expired 2017-09-09T16CM09378City permit recordCOMBOUPGRADE UP TO 200AMPExpired
Show 36 older records
Permit history for this parcel — remaining 36 records
DateRecordWhatStatusValue
2015-04-03expired 2015-06-02T15EX00450City permit recordEXCAVINSTALL NEW 45' POLE & ANCHOR WORK ORDER # 289353Closed
2015-04-03T15TC00845City permit recordBARRICADINSTALL NEW 45' POLE & ANCHOR WORK ORDER # 289353Expired
2015-02-19T15CM01106City permit recordSolar PVSOLAR POLEWithdrwn
2014-06-20expired 2014-08-19T14EX00751City permit recordEXCAVBetween Sewer Manhole 8607-01 And Manhole 8354-01ms, Raise Manhole No 8607-01 To Grade And Pour Concrete Collar, 5'X5' Excavation Area In AsphaltClosed
2013-12-12expired 2014-02-10T13EX01307City permit recordEXCAVCut curb to widen existing opening by 5'.Closed
2013-04-11finaledT13CM02153City permit recordCOMBORECONNECT - ELECTRICFinal
2012-11-15finaledT12CM07315City permit recordCOMBOELECTRIC RECONNECTFinal
2012-06-07finaledT12CM03305City permit recordCOMBORECONNECT: ELECTRICFinal
2011-07-29finaledT11EL02020City permit recordELECTRECONNECT ELECTRIC; COMMFinal
2011-07-29finaledT11EL02021City permit recordELECTRECONNECT ELECTRIC; COMMFinal
2011-07-15finaledT11EL01903City permit recordELECTCOMM: ELEC RECONNECTFinal
2011-03-15expired 2011-09-11T11OT00491City permit recordC-OF-OC OF O: RETAIL TEA WHOLESALERZonecert
2010-06-29finaledT10BU01033City permit recordFence / wallADD GYPSUM BOARD TO AN EXISTING WALL FOR FIRE RATING. WALL IS CONTAINING OXYGEN TANKSFinal
2010-04-08expired 2010-10-05T10OT00766City permit recordSIGN18140Void
2010-03-31finaledT10OT00717City permit recordSIGN18140Final
2010-02-01finaledT10OT00244City permit recordC-OF-OC OF O: OFFICE/STORAGEFinal
2010-01-22finaledT10OT00170City permit recordC-OF-OC OF O: ANTIQUES APPRAISALSC of o
2009-08-07finaledT09OT01658City permit recordC-OF-OC OF O:RETAIL RODEO MECHANICAL INCFinal
2009-07-06finaledT09OT01365City permit recordC-OF-OC OF O: EQUIPMENT REPAIRC of o
2008-09-15T08OT02189City permit recordC-OF-OC OF O:STORAGE & SALESWithdrwn
2007-08-20finaledT07EL01548City permit recordELECTREPLACE:ELECTRIC SERVICEFinal
2005-11-08finaledT05OT02787City permit recordC-OF-OC OF O MECHANICAL SUBCONTRACTOR FOR DUCTWORKC of o
2005-08-09expired 2006-02-19T05OT01968City permit recordC-OF-OC OF O:DMEExpired
2005-05-27expired 2005-11-28T05EL01065City permit recordELECTRECONNECT:ELECTRICExpired
2004-09-24finaledT04EL01982City permit recordELECTGENERAL REPAIR:ELECTRIC SERVICE FOR 8 METERS (APA)Final
2004-04-27expired 2004-10-27T04EL00850City permit recordELECTRECONNECT:ELECTRIC:WAREHOUSEExpired
2003-05-06finaledT03BU01115City permit recordSPKLRFIRE SPKR:ADD 2Final
2002-03-19finaledT02CM01469City permit recordCOMBOFIRE BARRIER FOR OXYGEN STORAGEC of o
2002-03-13expired 2003-09-07T02OT00387City permit recordSIGNSIGN:3753Expired
2001-02-06T01OT00028City permit recordC-OF-OC OF O:RETAILWithdrwn
1998-05-14expired 1998-11-10T98ME00343City permit recordMECHAIR COND:REPLACEMENTExpired
1998-05-14expired 1998-11-10T98ME00344City permit recordMECHAIR COND:REPLACEMENTExpired
1998-03-12finaledT98EL00453City permit recordELECTREPAIR:ELECTRICFinal
1998-03-06expired 1998-09-05T98EL00411City permit recordELECTRECONNECT:ELECTRIC WAREHOUSE/OFFICEExpired
1997-08-20expired 1998-03-03T97EL01279City permit recordELECTRECONNECT:SHOWING ONLYExpired
1997-04-04expired 1997-10-25T97EL00300City permit recordELECTELEC UPGRADEExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (47)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 47 records
DateRecordWhatStatus
2018-12-12T18DV08033Code enforcement caseCode enforcement caseVoid
2018-10-10T18DV06566Code enforcement caseCode enforcement caseComplian
2015-09-28T15DV07161Code enforcement caseSignComplian
2010-11-03finaledT10FR02310Code enforcement caseCode enforcement caseComplete
2010-03-25finaledT10FR00658Code enforcement caseCode enforcement caseComplete
2010-03-25finaledT10FR00659Code enforcement caseCode enforcement caseComplete
2010-03-25finaledT10FR00660Code enforcement caseCode enforcement caseComplete
2010-03-25finaledT10FR00662Code enforcement caseCode enforcement caseComplete
Show 39 older records
Code enforcement history for this parcel — remaining 39 records
DateRecordWhatStatus
2010-02-24finaledT10FR00397Code enforcement caseCode enforcement caseComplete
2010-02-24finaledT10FR00398Code enforcement caseCode enforcement caseComplete
2010-02-24finaledT10FR00399Code enforcement caseCode enforcement caseComplete
2010-02-24finaledT10FR00400Code enforcement caseCode enforcement caseComplete
2010-02-24finaledT10FR00402Code enforcement caseCode enforcement caseComplete
2010-02-24finaledT10FR00403Code enforcement caseCode enforcement caseComplete
2010-02-23finaledT10FR00391Code enforcement caseCode enforcement caseComplete
2010-02-17finaledT10FR00371Code enforcement caseCode enforcement caseComplete
2010-02-17finaledT10FR00372Code enforcement caseCode enforcement caseComplete
2010-02-17finaledT10FR00373Code enforcement caseCode enforcement caseComplete
2010-02-16finaledT10FR00361Code enforcement caseCode enforcement caseComplete
2010-02-16finaledT10FR00362Code enforcement caseCode enforcement caseComplete
2010-02-16finaledT10FR00363Code enforcement caseCode enforcement caseComplete
2010-02-16finaledT10FR00365Code enforcement caseCode enforcement caseComplete
2010-02-16finaledT10FR00366Code enforcement caseCode enforcement caseComplete
2010-02-11finaledT10FR00350Code enforcement caseCode enforcement caseComplete
2010-02-10finaledT10FR00340Code enforcement caseCode enforcement caseComplete
2010-01-28finaledT10FR00220Code enforcement caseCode enforcement caseComplete
2010-01-28finaledT10FR00221Code enforcement caseCode enforcement caseComplete
2010-01-28finaledT10FR00222Code enforcement caseCode enforcement caseComplete
2007-08-07T07FR01503Code enforcement caseCode enforcement caseField
2005-11-14T05FR01781Code enforcement caseFireField
2005-11-09finaledT05FR01746Code enforcement caseCode enforcement caseComplete
2005-11-09finaledT05FR01747Code enforcement caseCode enforcement caseComplete
2005-11-09finaledT05FR01748Code enforcement caseCode enforcement caseComplete
2005-11-09T05FR01750Code enforcement caseFireField
2005-11-09T05FR01751Code enforcement caseFireField
2005-11-09T05FR01752Code enforcement caseFireField
2005-11-09T05FR01753Code enforcement caseFireField
2005-11-09T05FR01754Code enforcement caseFireField
2005-11-09T05FR01755Code enforcement caseFireField
2005-11-09finaledT05FR01757Code enforcement caseCode enforcement caseComplete
2005-11-08T05FR01731Code enforcement caseFireField
2005-11-08T05FR01733Code enforcement caseFireField
2005-11-08T05FR01734Code enforcement caseFireField
2005-11-08T05FR01736Code enforcement caseFireField
2005-11-08T05FR01739Code enforcement caseFireField
2005-11-01T05FR01705Code enforcement caseFireField
2005-11-01T05FR01706Code enforcement caseFireField

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13316027E — 44 permits on file from 1997 to 2023 (11 elect, 9 c-of-o, 7 combo, 3 excav) and 47 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.