Electrical permit history — 2200 N Wilmot Rd
2200 N Wilmot Rd, Tucson — built 1974, with 42 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
2200 N Wilmot Rd
Built 1974 — 1970s commercial stock · last permitted panel/service work 1999 (finaled)
Permanent link: Electrical permit history for 2200 N Wilmot Rd (aztucsonelectricalsolutions.com/property/13316025e/2200-n-wilmot-rd-tucson-az-85712) · Public records last checked 2026-08-17
- Parcel
- 13316025E
- Built
- 1974 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Office Building 2 Story
- Parcel size
- 1.05 acres
- Building area
- 17,819 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 1999 permit was finalized; the permit description states “UPGRADE:ELECTRICAL 200 AMP TO 400 AMP” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionGetting onLast permitted 1999 (27 years ago). City inspection record: last recorded inspection 2007-05-07; no approved final is shown. Contractor of record: NIGHT OWL ELECTRIC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T99EL01676 — UPGRADE:ELECTRICAL 200 AMP TO 400 AMP
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Most recent permit on record for this parcel: 2024-04-29 (TR-UTL-0424-00877) — Boring for 100ft in ROW and the other 100ft will be on private property.
Permit history (42)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-04-29finaled | TR-UTL-0424-00877City permit record | Right-of-Way (ROW) - UtilityBoring for 100ft in ROW and the other 100ft will be on private property | Complete | |
| 2023-09-21finaled | TR-UTL-0923-02552City permit record | Right-of-Way (ROW) - UtilityCox to aerial Overlash 330', pull 15' of fiber through existing conduit, bore 96' and place vault for system tie. | Complete | |
| 2017-03-02finaled | T17CM01678City permit record | COMBOINSTALL 3 NEW RRHS ON EXISTING TOWER-AT&T | Final | |
| 2014-07-10finaled | T14CM04297City permit record | COMBOCELL TOWER & SITE MODIFICATIONS | Final | |
| 2007-05-01finaled | T07OT01031City permit record | SIGN13046 | Final | |
| 2007-01-02 | T07OT00004City permit record | C-OF-OC OF O : PERSONAL TRAINING | Withdrwn | |
| 2006-08-03 | T06CM04443City permit record | COMBOADDITON:OFFICE T99CM04985 | Withdrwn | |
| 2006-07-20finaled | T06CM04256City permit record | COMBOTI: OFFICE PRINT SHOP | C of o |
Show 34 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2006-07-20finaled | T06CM04258City permit record | COMBOTI: PERMANANT MAKE UP OFFICE SUITE # 240 | C of o | |
| 2006-07-20finaled | T06CM04259City permit record | COMBOTI: OFFICE SUITE # 180 | C of o | |
| 2006-07-20expired 2007-10-24 | T06CM04260City permit record | COMBOTI: OFFICE RESEARCH | Expired | |
| 2006-07-20finaled | T06CM04261City permit record | COMBOTI: OFFICE SUITE # 260 | C of o | |
| 2006-07-12 | T06AN00735City permit record | ADDRNEW | Issued | |
| 2006-07-12 | T06AN00736City permit record | ADDRNEW | Issued | |
| 2006-07-12 | T06AN00737City permit record | ADDRNEW | Issued | |
| 2006-07-12 | T06AN00738City permit record | ADDRNEW | Issued | |
| 2006-07-12 | T06OT01832City permit record | C-OF-OC OF O:OFFICE | Withdrwn | |
| 2006-07-12 | T06OT01833City permit record | C-OF-OC OF O:OFFICE | Withdrwn | |
| 2006-07-12 | T06OT01834City permit record | C-OF-OC OF O:OFFICE | Withdrwn | |
| 2006-07-12 | T06OT01835City permit record | C-OF-OC OF O:RESEACH OFFICE | Withdrwn | |
| 2006-03-30 | T06CM01788City permit record | COMBOTI: PERMANENT MAKEUP STUDIO | Withdrwn | |
| 2006-03-30 | T06OT00882City permit record | C-OF-OC OF O | Withdrwn | |
| 2006-03-21 | T06AN00340City permit record | ADDRNEW | Issued | |
| 2006-01-17 | T06AN00074City permit record | ADDRNEW | Issued | |
| 2006-01-17 | T06OT00136City permit record | C-OF-OC OF O | Withdrwn | |
| 2005-12-02finaled | T05OT02973City permit record | SIGN10156 | Final | |
| 2005-11-29finaled | T05BU02835City permit record | BUILDAWNING SIGN | Final | |
| 2005-11-29finaled | T05OT02942City permit record | SIGN10129 | Final | |
| 2005-01-04finaled | T05OT00011City permit record | SIGNSIGN:ELECTRIC:8279 NORTH WILMOT PROPERTIES | Final | |
| 2004-11-08finaled | T04OT02240City permit record | SIGNSIGN:8045 INSTY-PRINTS | Final | |
| 2004-11-04finaled | T04OT02215City permit record | SIGNSIGN:8028 INSTY-PRINTS | Final | |
| 2004-11-03 | T04AN01053City permit record | ADDRNEW | Issued | |
| 2002-01-25expired 2002-08-25 | T02OT00146City permit record | SIGNSIGN:3594 | Expired | |
| 2001-08-22expired 2001-10-21 | T01EX00972City permit record | EXCAVEXCAV:100 LF CURB/SIDEWALK/ ROW IMPROVEMENTS | Closed | |
| 2000-11-09 | T00BU03337City permit record | TANKSINSTALL:500 GALLON FUEL TANK | Withdrwn | |
| 2000-11-09expired 2007-11-04 | T00BU03339City permit record | BUILD500 GAL. ABOVE GROUND FUEL TANK | Closed | |
| 2000-03-27expired 2000-05-26 | T00EX00473City permit record | EXCAVEXCAV:16 LF | Closed | |
| 2000-02-17finaled | T00BU00524City permit record | GRADINGGRADING:1003 CY CUT & 0 FILL | Final | |
| 1999-10-22expired 2002-04-21 | T99CM04985City permit record | Addition / alterationADDITION:OFFICE ROOM/REMODEL | Expired | |
| 1999-07-16finaled | T99EL01676City permit record | ELECTUPGRADE:ELECTRICAL 200 AMP TO 400 AMP | Final | |
| 1997-07-25finaled | T97OT00141City permit record | C-OF-OC OF O INSPECTION:OFFICE | C of o | |
| 1997-03-18finaled | T97OT00021City permit record | C-OF-OC OF O INSPECTION:OFFICE & REPAIR | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (5)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2010-04-16finaled | T10FR00756Code enforcement case | Code enforcement case | Complete |
| 2010-04-16finaled | T10FR00759Code enforcement case | Code enforcement case | Complete |
| 2010-04-16finaled | T10FR00760Code enforcement case | Code enforcement case | Complete |
| 2010-04-16finaled | T10FR00761Code enforcement case | Code enforcement case | Complete |
| 2005-12-12 | T05ZV00731Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 13316025E — 42 permits on file from 1997 to 2024 (9 combo, 9 c-of-o, 7 sign, 7 addrnew) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.