Electrical permit history — 6944 E Tanque Verde Rd

6944 E Tanque Verde Rd, Tucson — built 1984, with 46 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6944 E Tanque Verde Rd

Built 1984 — 1980s commercial stock · 46 permits on record; no permitted panel/service or HVAC work among them

Parcel
13315291B
Built
1984 (county record)
Jurisdiction
Tucson
Zoning
C-1
Assessor use
Nursing/Orphan/Rehabprofit Licensed
Parcel size
2.89 acres
Building area
55,351 sq ft (assessor record)
Sewer
Connection on file (1984, 2017) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 6944 E Tanque Verde Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1223-01381 — Upgrade to Cellular monitoring
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (3)

Recorded transfers from the Pima County Assessor — 3 of 3
DatePriceType
2020-03-02$16,750,000Warranty Deed
2017-01-04$8,200,000Warranty Deed
2006-03-30$8,250,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-01-07 (TF-FOP-0126-00026) — Residential and detox substance abuse facility.

Permit history (46)

Permit history for this parcel — 8 of 46 records
DateRecordWhatStatusValue
2026-01-07finaledTF-FOP-0126-00026City permit recordFire OperationalResidential and detox substance abuse facilityComplete
2024-09-03finaledTF-FOP-0924-01008City permit recordFire OperationalArizona Rehab CampusComplete
2023-12-08finaledTF-FCP-1223-01381City permit recordFire ConstructionUpgrade to Cellular monitoringComplete
2023-10-27finaledTR-UTL-1023-02800City permit recordRight-of-Way (ROW) - UtilityEMG 2679578 6944 E Tanque Verde Rd 14-15-06NE repair main rear south side of business lot in easement; 6lf dirt; mlmComplete
2023-10-16finaledTF-FCP-1023-01215City permit recordAddition / alterationdining room was expanded requiring an additional smoke detectors and audio visual.Complete
2023-08-30TF-FOP-0823-01440City permit recordFire OperationalVOID-Resubmitted under Permit#TF-FOP-0823-01443-Annual RenewVoid
2023-08-30finaledTF-FOP-0823-01443City permit recordFire OperationalAZ Rehab Campuses I-1 Beds 160Complete
2023-08-03finaledTR-UTL-0823-02194City permit recordRight-of-Way (ROW) - UtilityPRJ254999-1 COX TO TRENCH 57' AND BORE 9' AND OVERLASH 378' TO PLACE VAULT FOR CATV CONDUIT SYSTEM TIEComplete
Show 38 older records
Permit history for this parcel — remaining 38 records
DateRecordWhatStatusValue
2023-04-04expires 2026-09-25TD-DEV-0423-00200City permit recordDevelopment PackageFire Damage Remodel and Dining Area expansion of 367 SF to existing Building No. 7 (0.007% Expansion). No impact on parking or other site issues. New indoor dining area replaces existing exterior patio dining area. For PDSD Records only. Nick Ross authorized an expedited review.Issued
2022-05-20expired 2024-05-29T22CM03879City permit recordCommercial BuildingRepair exterior patio & deck damages due to a fire.Issued
2022-05-03finaledT22FO00416City permit recordFIREOPERARIZONA REHAB CAMPUS - 206 BEDSFinal
2022-01-11finaledT22FC00021City permit recordFIRECONSRe-piping hood suppression system to provide coverage for new appliances.Final
2021-02-18finaledT21FO00096City permit recordFIREOPERARIZONA REHAB CAMPUS 160 BEDS VENDOR ACCIDENTLY PAID TWICE - REFUNDED THROUGH LASERFICHE 37042Final
2020-01-21finaledT20CM00418City permit recordCOMBOGAS REPIPE -LAUNDRY ROOMFinal
2017-06-20finaledT17FO00545City permit recordFIREOPERinpatient Rehab Center - 162 BedsFinal
2017-03-15finaledT17FC00214City permit recordFIRECONSBLDG A - NEW FIRE SPRINKLER SYSTEM IN EXISTING BUILDING - 86 NEW SPRINKLERSFinal
2017-03-08finaledT17FC00189City permit recordFIRECONSBUILDING A - FIRE ALARMFinal
2017-03-08finaledT17FC00190City permit recordFIRECONSBUILDING B - FIRE ALARMFinal
2017-03-08finaledT17FC00191City permit recordFIRECONSBUILDING C - FIRE ALARMFinal
2017-03-08finaledT17FC00192City permit recordFIRECONSBUILDING D - FIRE ALARMFinal
2017-03-08finaledT17FC00193City permit recordFIRECONSBUILDING F - FIRE ALARMFinal
2017-03-08finaledT17FC00194City permit recordFIRECONSBUILDING G - FIRE ALARMFinal
2017-02-28finaledT17FC00164City permit recordFIRECONSNew fire sprinkler system in existing building "C"Final
2017-02-24expired 2017-09-03T17CM01516City permit recordCOMBOLIFE SAFETY ACCESS CONTROLExpired
2017-02-21finaledT17FC00152City permit recordFIRECONSNew Fire Sprinkler System in existing building "B"= 243 New SprinklersFinal
2017-02-15finaledT17FC00142City permit recordFIRECONSNEW ALARM SYSTEM- BLDG EFinal
2017-02-10finaledT17CM01138City permit recordCOMBORESIDENTIAL CARE - BLDG BC of o
2017-02-10finaledT17CM01141City permit recordCOMBORESIDENTIAL CARE - BLDG CC of o
2017-02-10finaledT17CM01145City permit recordCOMBORESIDENTIAL CARE - BLDG DC of o
2017-02-10finaledT17CM01146City permit recordCOMBORESIDENTIAL CARE - BLDG FC of o
2017-01-30finaledT17FC00089City permit recordFIRECONSBLDG D - New Fire Sprinkler System in existing buildingFinal
2017-01-30finaledT17FC00090City permit recordFIRECONSBLDG F New Fire Sprinkler System in Existing buildingFinal
2017-01-24finaledT17FC00072City permit recordFIRECONSInstall one Kitchen Hood SystemFinal
2017-01-19expired 2017-07-26T17FC00053City permit recordFIRECONSBLDG E - FIRE ALARM SYSTEMVoid
2017-01-19finaledT17FC00055City permit recordFIRECONSFIRE CODE OFFICIAL APPEAL and FIRE ALARM BLD "E"Final
2017-01-13finaledT17OT00055City permit recordSIGNCHANGE OF COPY on DFFinal
2017-01-06finaledT17CM00136City permit recordCOMBOREHABILITATION FACILITYC of o
2016-12-28finaledDP16-0237City permit recordDevelopment PackageAZ REHAB CLINICComplete
2016-11-16finaledT16FC00238City permit recordFIRECONSAdd 140 new sprinkler heads-Bld EFinal
2016-10-07finaledT16CM07684City permit recordCOMBORESIDENTIAL CARE BLDG 1C of o
2016-09-22finaledT16CM07294City permit recordCOMBODETOX FACILITY - BLDG EC of o
2015-03-27finaledT15CM02019City permit recordCOMBOWIDEN DOOR OPENINGS AND RE-FRAME-INSTALL AUTOMATIC BREAK AWAY SLIDERSL of c
2007-07-24finaledT07CM03105City permit recordCOMBOSTORAGE COINTAINER (T07DV04762)Final
2005-09-12finaledT05OT02238City permit recordSIGNSIGN: RAMADA INN FOOTHILLS 9672Final
2003-02-07finaledT03OT00196City permit recordSIGNSIGN:#5042Final
1998-11-24finaledT98ME00922City permit recordMECHPRESSURE VESSEL CERTIFICATE:TUC-22897,24437Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (9)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 9 records
DateRecordWhatStatus
2021-11-04T21DV07883Code enforcement caseFireComplian
2020-12-30T20DV08203Code enforcement caseSignComplian
2017-11-17T17DV06204Code enforcement caseRefuseNoverify
2016-03-17T16DV01603Code enforcement caseZoningComplian
2014-11-26T14DV09720Code enforcement caseRefuseReferred
2009-08-04T09DV04531Code enforcement caseCode enforcement caseComplian
2007-08-06T07DV07317Code enforcement caseFireInvalid
2007-05-24T07DV04762Code enforcement caseCode enforcement caseComplian
Show 1 older record
Code enforcement history for this parcel — remaining 1 records
DateRecordWhatStatus
2006-06-23T06ZV00439Code enforcement caseCode enforcement caseComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13315291B — 46 permits on file from 1998 to 2026 (17 firecons, 11 combo, 4 fire operational, 3 fireoper) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.