Electrical permit history — 1181 N El Dorado Pl

1181 N El Dorado Pl, Tucson — with 70 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

1181 N El Dorado Pl

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Build year not published — permits on file from 1997 · 70 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0824-00715 — To install 1-ea. sprinkler head at the front hall reception.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2013. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2008. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2008. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 3.1 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
133148660
Year constructed
1997 (earliest permit on file)
Permitting authority
Tucson
Zoning
C-1
Property type
True Condominium Common Area

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 70 building permits for this parcel dated between 1997 and 2025. By category the work is addition / alteration (33), fire automatic extinguishing system (15), trade permit (13) and state licensed facility operational fire (4). 53 of them carry a final inspection; the other 17 were issued, expired or are still open, which is not the same as work completed. There is 1 code-enforcement case recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 133148660. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85715 · Commercial & industrial reports · Homes in 85715 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N EL DORADO PL hold 234 City permits on record, 25 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (71 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025TC-COM-1225-02353Commercial Addition/Alteration PermitNeeds Resubmittal
2025TC-COM-0325-00481Commercial Addition/Alteration PermitComplete
2025CE-VIO0525-02064Code enforcement caseReferred
2024TF-FCP-0824-00715Fire Automatic Extinguishing System PermitComplete
2023TF-FCP-0823-00934Fire Alarm System PermitExpired
2023TC-COM-0323-00828Commercial Addition/Alteration PermitIssued
2023TF-FOP-0423-00858State Licensed Facility Operational Fire PermitComplete
2021T21FO00032State Licensed Facility Operational Fire PermitComplete
2020T20FO00602State Licensed Facility Operational Fire PermitComplete
2020T20FO00603State Licensed Facility Operational Fire PermitComplete
2017T17OT00992Permanent Sign PermitComplete
2017T17FC00611Fire Alarm System PermitComplete
2017T17FC00576Fire Automatic Extinguishing System PermitComplete
2017T17CM04457Commercial Addition/Alteration PermitComplete
2017T17CM04456Commercial Addition/Alteration PermitComplete
2015T15BU01456Fire Automatic Extinguishing System PermitComplete
2015T15CM08831Residential Trade PermitWithdrawn
2014T14BU00408Fire Automatic Extinguishing System PermitComplete
2014T14CM01468Commercial Addition/Alteration PermitComplete
2013T13CM06726Commercial Trade PermitComplete
2011T11OT01459Commercial Addition/Alteration PermitComplete
2011T11OT01460Commercial Addition/Alteration PermitComplete
2011T11CM02327Commercial Addition/Alteration PermitComplete
2011T11CM02124Commercial Addition/Alteration PermitComplete
2011T11CM02328Commercial Addition/Alteration PermitComplete
2011T11CM02329Commercial Addition/Alteration PermitComplete
2011T11CM02330Commercial Addition/Alteration PermitComplete
2011T11CM02331Commercial Addition/Alteration PermitComplete
2010T10OT01192Commercial Addition/Alteration PermitWithdrawn
2009T09CM03020Commercial Addition/Alteration PermitComplete
2008T08BU02095Fire Automatic Extinguishing System PermitComplete
2008T08CM03570Commercial Addition/Alteration PermitComplete
2008T08CM02680Commercial Addition/Alteration PermitComplete
2008T08OT01936Commercial Addition/Alteration PermitWithdrawn
2008T08EL01224Commercial Trade PermitComplete
2008T08EL01226Commercial Trade PermitComplete
2008T08EL01225Commercial Trade PermitComplete
2008T08EL01227Commercial Trade PermitComplete
2008T08EL01223Commercial Trade PermitComplete
2008T08CM01089Commercial Addition/Alteration PermitComplete
2008T08CM01088Commercial Addition/Alteration PermitCanceled
2008T08BU00827Fire Automatic Extinguishing System PermitComplete
2008T08BU00826Fire Automatic Extinguishing System PermitComplete
2008T07CM04769Commercial Addition/Alteration PermitCanceled
2008T07CM04770Commercial Addition/Alteration PermitCanceled
2008T07CM04768Commercial Addition/Alteration PermitCanceled
2008T07CM04778Commercial Addition/Alteration PermitComplete
2001T01OT01103Permanent Sign PermitComplete
2000T00CM01725Commercial Addition/Alteration PermitComplete
2000T00BU01062Fire Automatic Extinguishing System PermitComplete
1999T99BU01355Fire Automatic Extinguishing System PermitComplete
1999T99CM02275Commercial Addition/Alteration PermitCanceled
1999T99ME00569Commercial Trade PermitComplete
1999T99ME00570Commercial Trade PermitComplete
1999T99ME00568Commercial Trade PermitComplete
1999T99ME00566Commercial Trade PermitComplete
1999T99ME00571Commercial Trade PermitComplete
1998T98BU00734Fire Automatic Extinguishing System PermitComplete
1998T98CM01118Commercial Addition/Alteration PermitCanceled
1998T98BU00054Fire Automatic Extinguishing System PermitComplete
1997T97CM04059Commercial Trade PermitComplete
1997T97BU02384Fire Automatic Extinguishing System PermitComplete
1997T97CM03430Commercial Addition/Alteration PermitCanceled
1997T97BU02091Fire Automatic Extinguishing System PermitComplete
1997T97CM03255Commercial Addition/Alteration PermitCanceled
1997T97BU01397Commercial Addition/Alteration PermitComplete
1997T97BU01558Fire Automatic Extinguishing System PermitComplete
1997T97CM02054Commercial Addition/Alteration PermitCanceled
1997T97BU00569Fire Automatic Extinguishing System PermitComplete
1997T97CM00603Commercial Addition/Alteration PermitCanceled
1997T97BU00168Commercial DemolitionWithdrawn

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 133148660 — 70 City permits on file from 1997 to 2025 and 1 code enforcement case — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The assessor’s building record, the sewer connection file and the flood map were also not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).