Electrical permit history — 9855 E Speedway Bl

9855 E Speedway Bl, Tucson — built 2009, with 37 permits on record. Review electrical, HVAC and remodel history with links to official records.

Multifamily property

9855 E Speedway Bl

Built 2009 — 2000s multifamily stock · 37 permits on record; no permitted panel/service or HVAC work among them

Parcel
13303300A
Built
2009 (county record)
Jurisdiction
Tucson
Zoning
O-3
Assessor use
Apartments 25 - 99 Units 2 Story
Parcel size
4.77 acres
Building area
97,320 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 9855 E Speedway Bl, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0124-00062 — Replace the existing Dedicated Function Fire Panel (Firelite MS-9050) with a new Firelite ES-50X fire panel and TG-7FS Cellular communicator for sprinkler monitoring. All existing addressable devices are compatible and shall remain in place. A new pull station is to be added next to the FACP.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Worth confirming

    A pool or spa was permitted in 2009. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2024-01-25 (TF-FCP-0124-00062) — Replace the existing Dedicated Function Fire Panel (Firelite MS-9050) with a new Firelite ES-50X fire panel and TG-7FS Cellular communicator for sprinkler monitoring. All existing addressable devices are compatible and shall remain in place. A new pull station is to be added next to the FACP..

Permit history (37)

Permit history for this parcel — 8 of 37 records
DateRecordWhatStatusValue
2024-01-25finaledTF-FCP-0124-00062City permit recordFire ConstructionReplace the existing Dedicated Function Fire Panel (Firelite MS-9050) with a new Firelite ES-50X fire panel and TG-7FS Cellular communicator for sprinkler monitoring. All existing addressable devices are compatible and shall remain in place. A new pull station is to be added next to the FACP.Complete
2023-05-22expired 2024-11-03TS-PRM-0523-00322City permit recordFence / wall2 - single face internally illuminated cabinets replacing existing signs mounted on existing masonry entry wallIssued
2023-01-05expired 2023-07-04TC-COM-0123-00425City permit recordPool / spaResurface swimming pool, new waterline tile, new pump(Pentair Whisperflo 2.6 VST), new sand filter(TR 100 sand filter), LED pool lights(white), Vacless(SVR System), 320 Rainbow Chlorinator, new flometer, new pressure gauge Exisiting equipment: Pentair Cartridge Filter Model 320, Pentair pump Intelliflo VS + SVRSExpired
2015-06-16finaledT15CM04046City permit recordCOMBO(T15DV04388) DAMAGE REPAIR CAR WENT THREW BLDGL of c
2014-07-07finaledT14BU00762City permit recordBUILDFIRE ALARM-SPRINKLER MONITORINGFinal
2012-02-14finaledT12BU00214City permit recordBUILDFIRE ALARMFinal
2010-03-19finaledT10CM00683City permit recordCOMBOPHOTOVOLTAIC SYSTEM 6.7 KW DCFinal
2010-03-02finaledT10OT00465City permit recordSIGN17988Final
Show 29 older records
Permit history for this parcel — remaining 29 records
DateRecordWhatStatusValue
2010-02-12finaledT10CM00347City permit recordCOMBO20 CARPORT STRUCTURES:Final
2010-02-12finaledT10CM00348City permit recordAddition / alterationADDITION: ONE CARPORT STRUCTUREFinal
2010-01-12finaledT10CM00062City permit recordCOMBOTEMP CONSTRUCTION TRAILERFinal
2009-12-24finaledT09BU01896City permit recordSPKLRInstall 72 fire sprinklersFinal
2009-12-09finaledT09BU01803City permit recordPool / spaPOOL:SEMI PUBLIC W/90' OF 5' WROUGHT IRON FENCE & GATESFinal
2009-10-16finaledT09BU01551City permit recordSPKLRInstall 120 fire sprinklersFinal
2009-10-15finaledT09BU01539City permit recordSPKLRInstall 100 fire sprinklersFinal
2009-10-15finaledT09BU01540City permit recordSPKLRInstall 100 fire sprinklersFinal
2009-10-15finaledT09BU01541City permit recordSPKLRInstall 100 fire sprinklersFinal
2009-10-15finaledT09BU01542City permit recordSPKLRInstall 100 fire sprinklersFinal
2009-09-04finaledT09BU01332City permit recordSPKLRInstall 73 fire sprinklersFinal
2009-09-04finaledT09BU01335City permit recordSPKLRInstall 120 fire sprinklersFinal
2009-09-04finaledT09BU01337City permit recordSPKLRInstall 100 fire sprinklersFinal
2009-07-30finaledT09BU01113City permit recordSPKLRInstall 72 fire sprinklersFinal
2009-07-28finaledT09BU01101City permit recordSPKLRINSTALL:120 FIRE SPRINKLERSFinal
2009-07-21finaledT09BU01065City permit recordSPKLRInstall 10 fire sprinklersFinal
2009-07-21finaledT09BU01067City permit recordSPKLRInstall 100 fire sprinklersFinal
2009-06-09finaledT09BU00833City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-06-09finaledT09BU00834City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-06-09finaledT09BU00835City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-06-09finaledT09BU00836City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-06-09finaledT09BU00837City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-06-09expired 2009-12-06T09BU00838City permit recordFence / wallFOUNDATION/RETAINING WALLSClosed
2009-06-09finaledT09BU00839City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-06-09finaledT09BU00840City permit recordFence / wallFOUNDATION/RETAINING WALLSFinal
2009-05-20finaledT09CM01282City permit recordCOMBOTEMP CONSTRUCTION TRAILERFinal
2009-04-21expired 2010-05-08T09EX00239City permit recordEXCAVEXCA:45' WATER LINE & 45' TO INSTALL DRY UTILITIESClosed
2007-12-14DS07-53City permit recordZoning Verification Letter9855 E SPEEDWAY BLVD - 9855 E. SPEEDWAY BLVD - DS 2-08.4.1.BApproved
2007-10-02D07-0041City permit recordADU / casitaTANQUE VERDE VALLEY CASITASApproved

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2022-09-23T22DV05503Code enforcement caseVegetationClosed - unfounded
2016-12-07T16DV08238Code enforcement caseFireComplian
2015-06-15T15DV04388Code enforcement caseCode enforcement caseComplian
2012-06-07T12DV04774Code enforcement caseCode enforcement caseNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13303300A — 37 permits on file from 2007 to 2024 (13 spklr, 9 fence / wall, 5 combo, 2 pool / spa) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).