Electrical permit history — 10760 E Tanque Verde Rd

10760 E Tanque Verde Rd, Tucson — built 1968, with 18 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

10760 E Tanque Verde Rd

Built 1968 — aluminum branch-wiring era · 18 permits on record; no permitted panel/service or HVAC work among them

Parcel
13302040F
Built
1968 (assessor record — effective construction year, which can move after a major remodel)
Jurisdiction
Unincorporated Pima County
Zoning
CR-1
Assessor use
Sfr Grade 010-3 Urban Non-Subdivided
Parcel size
1.15 acres
Living area
2,947 sq ft (assessor record)
Cooling
Refrigeration (assessor record)
Heating
Forced Air (assessor record)
Roof
Asphalt (assessor record)
Pool
Yes (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Typical original service for a 1968 home
approximately 100 A

See the property

County aerial photograph centered on 10760 E Tanque Verde Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 1997 damage/demo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not tell you the service is original — only that nothing has been permitted here recently. The build year is the better clue, and it is above.
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 1997 damage/demo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. The assessor records cooling as Refrigeration and heating as Forced Air. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Asphalt.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    This is the aluminum branch-circuit window (roughly 1965–1973). Solid aluminum on 15/20 A circuits is a recognized fire hazard at the terminations and needs approved repair — COPALUM or AlumiConn, not a wire nut. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    100 A was typical. Adding an EV charger, heat pump, or casita usually forces a service upgrade first. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    The assessor records a pool on this parcel. Equipment bonding, the equipotential bonding grid and GFCI protection on the pump and light circuits are the usual findings on pool equipment — the pool-bonding rules in NEC Article 680 were expanded in the 2008 cycle, so a pool built before that is worth an on-site check.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2018-11-16$416,500Warranty Deed
2002-05-28$225,000

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2020-10-23 (P20BP07395) — Mechanical/Plumbing Equipment.

Permit history (18)

Permit history for this parcel — 8 of 18 records
DateRecordWhatStatusValue
2020-10-23P20BP07395Pima County permitElectrical / mechanicalMechanical/Plumbing EquipmentPermit Expired
2020-10-06P20BP05354-02Pima County permitRevisionElectrical Equipment - RevisionApproved
2020-09-30P20BP05354-01Pima County permitRevisionElectrical Equipment - RevisionApproved
2020-08-12P20FC00595Pima County permitFloodplain UseSOLIssued
2020-08-11finaledP20BP05354Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2020-06-25P20FC00455Pima County permitFloodplain UseSOLIssued
2020-06-24finaledP20BP04095Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2018-10-24finaledP18RR00357Pima County permitPublic Records RequestSeptic Records RequestComplete
Show 10 older records
Permit history for this parcel — remaining 10 records
DateRecordWhatStatusValue
2008-04-18finaledP08CP02858Pima County permitHistoricalPLUMB/SOTH -Final
2006-11-16P06RW02667Pima County permitRight of WayROW/RDRI - — 10760 E TANQUE VERDE RDApplication Expired
2002-05-30finaledP02CP05516Pima County permitPool / spaPOOL/SPA/PRES -Final
2000-05-01P00CP04508Pima County permitHistoricalCOMBO/SOTH -Application Expired
1998-07-11DEQ-010613Pima County permitSepticSEPTHIST/ -CA Issued
1998-05-29P98RW01185Pima County permitRight of WayROW/RWAT - — 10760 E TANQUE VERDE RDIssued
1997-05-27P97CP06248Pima County permitRight of WayROW/RWAT - — 10760 E TANQUE VERDE RDIssued
1997-04-22finaledP97CP04627Pima County permitDamage/DemoFIREDAMG/SOTH -Final
1997-04-01finaledP97CP03570Pima County permitHistoricalCOMBO/SOTH -Final
1993-12-20finaled79646Pima County permitHistoricalPMSHIST/ -Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13302040F — 18 permits on file from 1993 to 2020 (4 historical, 3 electrical / mechanical, 3 right of way, 2 revision) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.