Electrical permit history — 1229 E Kentucky St

1229 E Kentucky St, Tucson — built 1962, with 4 permits on record. Review electrical, HVAC and remodel history with links to official records.

Home

1229 E Kentucky St

Built 1962 — post-war 60–100 A service era · last permitted panel/service work 2018 (finaled)

Parcel
132180820
Built
1962 (county record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Condo/Twnhm/Row/Patio Grade 3
Parcel size
0.06 acres
Living area
816 sq ft (assessor record)
Cooling
Evaporative (assessor record)
Heating
Wall Furnace (assessor record)
Roof
Built Up (assessor record)
Garage
Carport (1-car) (assessor record)
Sewer
Connection on file (1962) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Typical original service for a 1962 home
approximately 60–100 A
Service on record
City records show the 2018 permit was finalized; the permit description states “ELECTRICAL UPGRADE NOT TO EXCEED 200AMPS” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 1229 E Kentucky St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & panelCurrentLast permitted 2018 (8 years ago). City inspection record: ELECTRIC - FINAL approved 2018-09-25. Contractor of record: VETERAN'S PLUMBING & DRAIN LLC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T18CM07074 — ELECTRICAL UPGRADE NOT TO EXCEED 200AMPS
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records cooling as Evaporative and heating as Wall Furnace. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Built Up.
  • Plumbing work on recordNot in this windowNothing in the permit records we read for this parcel that names this system. Unremarkable — plenty of buildings never need a permitted plumbing repair.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    60–100 A was standard. That is enough for a mid-century house, not for a modern kitchen, HVAC, and an EV. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Federal Pacific (Stab-Lok) and Zinsco/Sylvania panels were sold through this period. Stab-Lok breakers have a documented history of failing to trip internally; Zinsco breakers can weld to the bus so the handle moves without breaking the circuit. In both cases a replacement breaker does not resolve it — the panel itself is what gets replaced. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Grounded branch circuits did not become the norm until the early 1960s — much of the original wiring here is likely ungrounded. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    Cloth-jacketed NM cable is common in this era. The jacket embrittles with age and heat, particularly in Tucson attics. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2023-03-24 (TC-RES-0323-03839) — • SYSTEM SIZE: 2960W DC, 2320W AC • MODULES: (8) MISSION SOLAR ENERGY LLC: TXI6-370120BB • INVERTERS: (8) ENPHASE ENERGY: IQ8PLUS-72-2-US • RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE WITH STANDOFF TO RAFTER: SNR-DC-01249.

Permit history (4)

Permit history for this parcel — 4 of 4 records
DateRecordWhatStatusValue
2023-03-24expired 2023-09-20TC-RES-0323-03839City permit recordSolar PV• SYSTEM SIZE: 2960W DC, 2320W AC • MODULES: (8) MISSION SOLAR ENERGY LLC: TXI6-370120BB • INVERTERS: (8) ENPHASE ENERGY: IQ8PLUS-72-2-US • RACKING: ULTRA RAIL, ATTACHMENT DETAIL, OMNIBASE WITH STANDOFF TO RAFTER: SNR-DC-01249Expired
2023-02-09expired 2023-12-25TC-RES-0223-02743City permit recordResidential Building - One or Two Familyroof mounted PV system 11 x 400W panels 1 x 5kw inverter 20A BreakerIssued
2018-12-12expired 2019-06-11T18CM09704City permit recordCOMBOINSTALL PV SYSTEM AND RELATED MATERIALSExpired
2018-09-07finaledT18CM07074City permit recordCOMBOELECTRICAL UPGRADE NOT TO EXCEED 200AMPSFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 132180820 — 4 permits on file from 2018 to 2023 (2 combo, 1 solar pv, 1 residential building - one or two family) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.