Electrical permit history — 4300 S Park Av

4300 S Park Av, Tucson — built 1993, with 51 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4300 S Park Av

Built 1993 — 1990s commercial stock · last permitted panel/service work 2018 (finaled) · HVAC 2005 (finaled)

Parcel
13216600B
Built
1993 (assessor record)
Jurisdiction
Tucson
Zoning
R-2
Assessor use
Municipal Police/Fire Department Facility
Parcel size
3.19 acres
Building area
18,719 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2018 permit was finalized; the permit description states “WO# 1807356 - 4220 S Park Av #11 - New service install - 80' x 45' area - P/O in white paint - In front north corner of Building #11 - There is no address identified but building has #11 posted on it - Need to enter through guard shack”.

See the property

County aerial photograph centered on 4300 S Park Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2018 (8 years ago). City inspection record: last recorded inspection 2018-10-01; no approved final is shown. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T18RW02429 — WO# 1807356 - 4220 S Park Av #11 - New service install - 80' x 45' area - P/O in white paint - In front north corner of Building #11 - There is no address identified but building has #11 posted on it - Need to enter through guard shack
  • Heating, cooling & mechanicalLikely dueLast permitted 2005 (21 years ago). City inspection record: MECHANICAL - FINAL approved 2005-06-16. Contractor of record: T R S AIR CONDITIONING SERVICES AND CONSTRUCTION. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T05CM01719 — REPLACE: CHILLER
  • Fire alarm & life safetyCurrentLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00153 — COT Property - Add 2nd communicator cell to existing fire system
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2019. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2026-01-21 (TR-UTL-0126-00139) — Zayo contractor to pull fiber thru existing underground conduit. Zayo contractor to access existing HH's to facilitate pull thru of fiber..

Permit history (51)

Permit history for this parcel — 8 of 51 records
DateRecordWhatStatusValue
2026-01-21TR-UTL-0126-00139City permit recordRight-of-Way (ROW) - UtilityZayo contractor to pull fiber thru existing underground conduit. Zayo contractor to access existing HH's to facilitate pull thru of fiber.Needs resubmittal
2026-01-07TR-UTL-0126-00047City permit recordRight-of-Way (ROW) - UtilityZayo contractor to pull fiber thru existing underground conduit. Zayo contractor to accesss existing HH's to facilitate pull thru of fiber.Needs resubmittal
2024-07-16expired 2025-04-02TC-UTL-0724-00042City permit recordUtilities· REMOVE ALL ANTENNAS · REMOVE ALL RRHS · REMOVE EXISTING ANTENNA MOUNTS · REMOVE ALL NOKIA EQUIPMENT · INSTALL (3) SECTOR FRAME MOUNTS · INSTALL (3) 840-370966K A1/B1/C1 · INSTALL (3) AIR6419 B77D+AIR6419 B77G STACKED ON POS A2/B2/C2 · INSTALL (3) 840-370799K ANTENNAS ON A3/B3/C3 · INSTALL (3) 4490 B5/B12'S RADIOS ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4415 B30'S FOR A1/B1/C1 (N) 10' PIPES ON SECTOR “V” · INSTALL (3) 4890 B25/B66 ON SXK1255394/2 B2B'S TO BE SHARED W/ (3) 4478 B14'S FOR A3/B3/C3 (N) 10' PIPES ON ON SECTOR “V” · RETAIN (1) WCS-IMFT-AMT FILTER IN B1Issued
2022-07-29expired 2024-10-05T22CM05819City permit recordCommercial BuildingTHIS PROJECT WILL BE COMPRISED OF:CHANGES ON THE EXISTING AT&T ANTENNA ARRAY:· POSITION (3) - REPLWithdrawn
2022-03-29expired 2023-05-12T22FC00232City permit recordFire ConstructionFlammable & Combustible Liquid - Emergency generator with diesel belly tank to provide back-up power at cell tower when electric power from the local utility is interrupted.; Other Construction PermitIssued
2022-02-23finaledT22FO00173City permit recordFire OperationalFlammable & Combustible Liquid - EMERGENCY GENERATOR TO PROVIDE BACK-UP POWER AT CELL TOWER WHEN ELECTRIC POWER FROM THE LOCAL UTILITY IS INTERRUPTED.; Other Operational PermitComplete
2021-11-30finaledT21RW05102City permit recordROWLANE CLOSURE TO WORK IN TELECOM MANHOLE IN SOUTHBOUND BIKE LANE ON PARK AV FOR ZAYO GROUP. ADDRESS ON APPLICATION IS 4220 S PARK AV ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. 1. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. 3. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 4. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 5. MAINTAIN PEDESTRIAN ACCESS 6. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. 7. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813Final
2021-02-25finaledT21FC00153City permit recordFIRECONSCOT Property - Add 2nd communicator cell to existing fire systemFinal

43 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (19)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 19 records
DateRecordWhatStatus
2016-01-12T16DV00153Code enforcement caseCode enforcement caseComplian
2013-01-10T13DV00223Code enforcement caseSignComplian
2011-02-08finaledT11FR00397Code enforcement caseFireComplete
2011-01-26T11FR00245Code enforcement caseCode enforcement caseField
2011-01-18T11FR00172Code enforcement caseCode enforcement caseField
2010-12-30finaledT10FR02764Code enforcement caseCode enforcement caseComplete
2010-10-27T10FR02266Code enforcement caseCode enforcement caseField
2010-10-06T10FR02049Code enforcement caseFireField
Show 11 older records
Code enforcement history for this parcel — remaining 11 records
DateRecordWhatStatus
2010-05-21finaledT10FR01022Code enforcement caseCode enforcement caseComplete
2010-01-28finaledT10FR00234Code enforcement caseFireComplete
2009-10-19finaledT09FR03302Code enforcement caseFireComplete
2009-10-13T09FR03259Code enforcement caseFireField
2009-04-21finaledT09FR01362Code enforcement caseCode enforcement caseComplete
2009-02-02finaledT09FR00429Code enforcement caseCode enforcement caseComplete
2008-10-27finaledT08FR03958Code enforcement caseFireComplete
2008-10-01T08FR03417Code enforcement caseCode enforcement caseField
2008-05-22T08FR01289Code enforcement caseFireField
2007-08-23finaledT07FR01649Code enforcement caseCode enforcement caseComplete
2007-05-09T07FR00912Code enforcement caseCode enforcement caseField

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13216600B — 51 permits on file from 1999 to 2026 (16 combo, 4 spklr, 3 commercial building, 3 row) and 19 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.