Built 1975 — 1970s commercial stock · HVAC 2012 (finaled)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 row permit - development/building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalGetting onLast permitted 2012 (14 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T11CM03044 — TI/REPLACE HVAC
  • Fire alarm & life safetyFinaled permit foundA newer 2025 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “EXPEDITE - Install Cell Dialer”. Last permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0725-00612 — Fire Suppression system install
  • RoofLikely dueLast permitted 2003 (23 years ago). Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar. T02CM04124 — REMOVE:PARAPET & RE-ROOF

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2019. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Worth confirming

    A pool or spa was permitted in 2007. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2024. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 445,186 sq ft (county building-footprint layer, 23 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 311,600 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 3,430 kW — roughly 8,580 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 5,640,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$451,000–$733,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 2.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13216600A
Year constructed
1975 (assessor record)
Permitting authority
Tucson
Zoning
I-1
Property type
Municipal Commercial Property
Building area
369,012 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 292 building permits for this parcel dated between 1997 and 2026. By category the work is trade permit (92), addition / alteration (67), fire automatic extinguishing system (36) and registered facility annual (13). 179 of them carry a final inspection; the other 113 were issued, expired or are still open, which is not the same as work completed. There are 13 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13216600A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85714 · Commercial & industrial reports · Homes in 85714 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S PARK AV hold 600 City permits on record, 147 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (305 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-0826-01263Commercial Solar PermitIssued
2026TC-COM-0926-01560Commercial Addition/Alteration PermitSubmitted - Online
2026TD-DEV-0526-00121Development PackageInspections
2026CE-VIO0626-02665Code enforcement caseClosed - Administrative
2026TC-CFO-0526-00089Temporary Certificate-of-Occupancy (TCO)Inspections
2026recordRight-of-Way (ROW) Permit - UtilityInspections
2026TC-UTL-0526-00064Private Utilities PermitFees Due
2026recordROW Permit - City CIP/JOCInspections
2026TC-COM-0426-00540Commercial Addition/Alteration PermitIssued
2026recordROW Permit - Development/BuildingVoid
2026recordROW Permit - Development/BuildingInspections
2026TC-REG-0126-00001Registered Facility Annual PermitFees Paid
2025recordROW Permit - Development/BuildingComplete
2025recordROW Permit - Development/BuildingComplete
2025recordRight-of-Way (ROW) Permit - GeneralInspections
2025TF-FCP-1125-00995Fire Alarm System PermitExpired
2025recordRight-of-Way (ROW) Permit - UtilityComplete
2025recordRight-of-Way (ROW) Permit - GeneralComplete
2025TF-FCP-0725-00612Fire Automatic Extinguishing System PermitComplete
2025TE-FPU-0725-00300Floodplain Use PermitIssued
2025recordRight-of-Way (ROW) Permit - GeneralComplete
2025TF-FCP-0425-00288Fire Automatic Extinguishing System PermitNeeds Resubmittal
2025TC-REG-0325-00008Registered Facility Annual PermitFees Due
2025recordRight-of-Way (ROW) Permit - GeneralComplete
2025TF-FCP-1224-01121Fire Alarm System PermitComplete
2024TF-FCP-1224-01093Fire Automatic Extinguishing System PermitComplete
2024recordRight-of-Way (ROW) Permit - GeneralComplete
2024recordRight-of-Way (ROW) Permit - GeneralNeeds Resubmittal
2024recordRight-of-Way (ROW) Permit - UtilityComplete
2024recordRight-of-Way (ROW) Permit - GeneralVoid
2024TF-FCP-1124-00984Fire Automatic Extinguishing System PermitComplete
2024TC-COM-0423-00942Commercial New Building PermitApproved
2024recordRight-of-Way (ROW) Permit - UtilityInspections
2024TE-FPU-0824-00254Floodplain Use PermitIssued
2024recordRight-of-Way (ROW) Permit - UtilityComplete
2024TC-COM-0724-01304Commercial Trade PermitComplete
2024TE-FPU-0624-00183Floodplain Use PermitIssued
2024recordRight-of-Way (ROW) Permit - UtilityComplete
2024TC-COM-0224-00234Commercial Addition/Alteration PermitComplete
2024TC-BCA-0324-00012Building Code AppealApproved
2024TC-COM-0224-00289Commercial Trade PermitComplete
2024TD-DEV-0423-00198Development PackageInspections
2023recordROW Permit - City CIP/JOCComplete
2023recordRight-of-Way (ROW) Permit - UtilityComplete
2023TC-COM-1222-00288Commercial Addition/Alteration PermitComplete
2023recordROW Permit - City CIP/JOCNeeds Resubmittal
2023recordRight-of-Way (ROW) Permit - UtilityInspections
2023T22CM04604Commercial Addition/Alteration PermitIssued
2023recordROW Annual Permit - Utility MaintenanceComplete
2022TC-COM-1122-00026Commercial Trade PermitComplete
2022TC-REG-1122-00001Registered Facility Annual PermitApproved
2022T22CM05031Commercial Addition/Alteration PermitIssued
2022T22PRE0243Pre-Application ConferenceComplete
2022T22CM05819Commercial Trade PermitWithdrawn
2022DP22-0250 Development PackageCanceled
2022recordRight-of-Way (ROW) Permit - GeneralComplete
2022recordRight-of-Way (ROW) Permit - GeneralComplete
2022recordRight-of-Way (ROW) Permit - GeneralComplete
2022T22CM04407Commercial Trade PermitComplete
2022T22BU00177Commercial DemolitionComplete
2022T22DV02978VegetationClosed - Unfounded
2022T22FO00173General Operational Fire PermitComplete
2022T22FC00232Other IFC Construction PermitIssued
2022T22PRE0064Pre-Application ConferenceCanceled
2022recordRight-of-Way (ROW) Permit - GeneralComplete
2022T21CM09642Commercial Trade PermitIssued
2021T21OT00431Registered Facility Annual PermitExpired
2021T21FC00277Fire Alarm System PermitComplete
2021T21CM01605Commercial Addition/Alteration PermitComplete
2021T21FC00148Fire Automatic Extinguishing System PermitComplete
2020T20FC00793Fire Automatic Extinguishing System PermitComplete
2020T19CM09398Commercial Addition/Alteration PermitComplete
2020T20CM04411Commercial Addition/Alteration PermitExpired
2020T20FC00317Fire Alarm System PermitComplete
2020T19CM09024Commercial Trade PermitExpired
2020T20OT00031Registered Facility Annual PermitExpired
2019T19CM06308Commercial Addition/Alteration PermitComplete
2019T19CM06689Residential Solar PermitComplete
2019DP19-0241Development PackageApproved
2019T19CM05054Residential Solar PermitComplete
2019T19CM04766Residential Solar PermitComplete
2019T19CM04764Residential Solar PermitComplete
2019DP19-0158Development PackageComplete
2019T19OT00139Registered Facility Annual PermitExpired
2018T18CM06357Commercial Trade PermitComplete
2018T18DV06668SHOPPING CARTCANCEL
2018T18DV06666SHOPPING CARTCANCEL
2018T18DV06344CONDEMNATIONCANCEL
2018T18DV06345CONDEMNATIONCANCEL
2018T18DV06330SHOPPING CARTCANCEL
2018T18FO00812General Operational Fire PermitComplete
2018T18CM04143Commercial Trade PermitComplete
2018DP18-0126Development PackageIssued
2018T18CM03316Commercial Addition/Alteration PermitComplete
2018T17CM09539Commercial Trade PermitComplete
2018T18OT00130Registered Facility Annual PermitExpired
2017T16FC00126Fire Alarm System PermitExpired
2017T17FC00207Fire Alarm System PermitCanceled
2017T17FC00208Fire Alarm System PermitCanceled
2017T17OT00134Registered Facility Annual PermitExpired
2017T17BU00065Commercial DemolitionWithdrawn
2017T17CM01299Commercial Addition/Alteration PermitComplete
2016T16FC00136Fire Alarm System PermitExpired
2016T16FC00121Fire Alarm System PermitExpired
2016T16FC00124Fire Alarm System PermitExpired
2016T16FC00123Fire Alarm System PermitExpired
2016T16FC00094Fire Alarm System PermitExpired
2016T16FC00073Fire Alarm System PermitExpired
2016T16DV04613MULTI-AGENCY INSPECTION TEAMNOVERIFY
2016T16DV04612MULTI-AGENCY INSPECTION TEAMNOVERIFY
2016DP16-0091Development PackageApproved
2016T16BU00578Commercial Trade PermitCanceled
2016T16CM01261Commercial Trade PermitComplete
2016T16CM00094Commercial Trade PermitComplete
2016T16OT00292Registered Facility Annual PermitCanceled
2016T16BU00246Commercial Trade PermitCanceled
2016T16BU00257Commercial Trade PermitCanceled
2016T16DV00347MULTIPLE TYPESCOMPLIAN
2016T16DV00348MULTIPLE TYPESCOMPLIAN
2016T16DV00349MULTIPLE TYPESCOMPLIAN
2016T16DV00346MULTIPLE TYPESCOMPLIAN
2016T16BU00096Commercial Trade PermitComplete
2016T16SE00013Mayor Council Special ExceptionApproved
2015T15BU00929Fire Automatic Extinguishing System PermitComplete
2015T15BU00668Fire Automatic Extinguishing System PermitComplete
2015T14CM07391Commercial New Building PermitComplete
2015T14OT01601Floodplain Use PermitComplete
2015DP14-0202Development PackageComplete
2015T15OT00142Registered Facility Annual PermitCanceled
2015T14CM07827Commercial Trade PermitComplete
2014DP14-0185Development PackageComplete
2014T14BU00873Commercial Trade PermitComplete
2014T14BU00870Fire Automatic Extinguishing System PermitComplete
2014T14OT00174Registered Facility Annual PermitCanceled
2013T13BU00775Fire Automatic Extinguishing System PermitComplete
2013T13BU00495Commercial Trade PermitComplete
2013T12CM08100Commercial Addition/Alteration PermitCanceled
2013T13BU00169Commercial Trade PermitComplete
2013T13BU00166Fire Automatic Extinguishing System PermitCanceled
2013T12CM07618Commercial Trade PermitComplete
2013T12CM06013Commercial Addition/Alteration PermitCanceled
2012T12OT01657Registered Facility Annual PermitCanceled
2012T12BU01334Residential Addition/Alteration PermitComplete
2012T12BU00940Commercial Trade PermitComplete
2012T12BU00659Storage Tank PermitComplete
2012T11CM03044Commercial Trade PermitComplete
2012T11CM02877Commercial Trade PermitComplete
2012T11CM03045Commercial Trade PermitCanceled
2012T12CM00406Commercial Trade PermitComplete
2012T12CM00417Commercial Trade PermitComplete
2011T11BU01527Fire Automatic Extinguishing System PermitComplete
2011T11OT02108Registered Facility Annual PermitComplete
2011T11CM02560Residential Solar PermitComplete
2011T11CM02662Residential Solar PermitComplete
2011T11OT01669Floodplain Use PermitComplete
2011T11CM02654Commercial Trade PermitCanceled
2011T11EL02234Commercial Trade PermitComplete
2011T11BU00185Fire Automatic Extinguishing System PermitComplete
2011T11SE00004Zoning Examiner Special ExceptionCanceled
2010T10CM03334Commercial Addition/Alteration PermitComplete
2010T10PRE0089Pre-Application ConferenceCanceled
2010T10EL02575Commercial Trade PermitComplete
2010T10CM01790Commercial Trade PermitComplete
2010T10EL01509Commercial Trade PermitComplete
2010T10CM01603Commercial Addition/Alteration PermitComplete
2010T10OT01310Floodplain Use PermitComplete
2010T10CM01443Commercial Addition/Alteration PermitComplete
2009T09BU01866Fire Automatic Extinguishing System PermitComplete
2009T09CM02012Commercial Addition/Alteration PermitComplete
2009T09OT01584Floodplain Use PermitCanceled
2009T09BU00969Storage Tank PermitComplete
2009T09EL01456Commercial Trade PermitComplete
2008T08CM02135Commercial Addition/Alteration PermitComplete
2008T08BU01250Fire Automatic Extinguishing System PermitComplete
2007T07CM03023Commercial Addition/Alteration PermitComplete
2007T07EL02075Commercial Trade PermitComplete
2007T07BU01225Commercial Trade PermitComplete
2007T07CM01468Commercial Addition/Alteration PermitComplete
2007T06CM06090Commercial Trade PermitComplete
2007T06EL02360Commercial Trade PermitComplete
2007T07CM01071Commercial Trade PermitComplete
2007T06CM06008Commercial Addition/Alteration PermitComplete
2007T07BU00362Fire Automatic Extinguishing System PermitComplete
2006T06CM04864Commercial Addition/Alteration PermitComplete
2006T06BU02291Fire Automatic Extinguishing System PermitComplete
2006T06CM02768Commercial Addition/Alteration PermitComplete
2006T06CM00188Commercial Trade PermitComplete
2005T05CM02381Commercial Addition/Alteration PermitComplete
2005T05CM04144Commercial Trade PermitWithdrawn
2005T05BU02308Storage Tank PermitComplete
2005T05CM01508Commercial Addition/Alteration PermitCanceled
2005T05CM01719Commercial Trade PermitComplete
2005T04CM03054Commercial Addition/Alteration PermitComplete
2005T05ME00085Commercial Trade PermitWithdrawn
2005T05BU00228Fire Automatic Extinguishing System PermitComplete
2004T04CM02088Commercial Addition/Alteration PermitWithdrawn
2004T04CM01938Commercial Trade PermitComplete
2004T04OT00819Development PackageComplete
2004T04BU00432Fire Automatic Extinguishing System PermitComplete
2004T04BU00441Fire Automatic Extinguishing System PermitComplete
2004T04BU00324Fire Automatic Extinguishing System PermitComplete
2004T03CM05713Commercial Trade PermitComplete
2004T04EL00183Commercial Trade PermitWithdrawn
2004T03CM03909Commercial Addition/Alteration PermitCanceled
2004T03CM03910Commercial Addition/Alteration PermitCanceled
2003T03PL01356Commercial Trade PermitComplete
2003T03BU01593Fire Automatic Extinguishing System PermitCanceled
2003T02CM05547Commercial Addition/Alteration PermitWithdrawn
2003T02CM04124Commercial Addition/Alteration PermitComplete
2003T02CM04350Commercial Addition/Alteration PermitComplete
2003T02CM02960Commercial Addition/Alteration PermitCanceled
2002T02CM05736Commercial Addition/Alteration PermitComplete
2002T02CM02114Commercial Addition/Alteration PermitComplete
2002T02ME00379Residential Trade PermitCanceled
2002T01CM05890Commercial Addition/Alteration PermitCanceled
2002T01EL02420Commercial Trade PermitComplete
2002T02EL00786Commercial Trade PermitComplete
2002T02PL00812Commercial Trade PermitComplete
2002T02BU00705Fire Automatic Extinguishing System PermitComplete
2002T01CM03856Commercial Trade PermitComplete
2001T01BU02749Commercial Addition/Alteration PermitComplete
2001T01CM01769Commercial Addition/Alteration PermitComplete
2001T01BU02388Fire Automatic Extinguishing System PermitComplete
2001T01CM02809Commercial Trade PermitComplete
2001T01CM03253Commercial Trade PermitComplete
2001T01EL01374Commercial Trade PermitComplete
2001T01CM02836Commercial Trade PermitComplete
2001T01CM02727Commercial Trade PermitWithdrawn
2001T01CM01625Commercial Trade PermitWithdrawn
2001T01CM00994Commercial Addition/Alteration PermitComplete
2001T01BU00642Fire Automatic Extinguishing System PermitComplete
2001T00CM05263Commercial Addition/Alteration PermitComplete
2001T00CM03802Commercial Trade PermitCanceled
2001T00CM03803Commercial Trade PermitCanceled
2001T01CM00602Commercial Addition/Alteration PermitCanceled
2001T00CM05172Commercial Addition/Alteration PermitCanceled
2000T00BU03541Fire Automatic Extinguishing System PermitComplete
2000T00CM04937Commercial Addition/Alteration PermitComplete
2000T00ME01291Commercial Trade PermitWithdrawn
2000T00EL01981Commercial Trade PermitCanceled
2000T00CM03642Commercial Addition/Alteration PermitComplete
2000T00CM03602Commercial Addition/Alteration PermitComplete
2000T00CM03603Commercial Addition/Alteration PermitComplete
2000T00CM00133Commercial Addition/Alteration PermitComplete
2000T00CM00132Commercial Addition/Alteration PermitComplete
2000T00BU01327Fire Automatic Extinguishing System PermitComplete
2000T00CM02839Commercial Trade PermitComplete
2000T00CM02044Commercial Addition/Alteration PermitComplete
2000T00BU01455Fire Automatic Extinguishing System PermitWithdrawn
2000T00EL01256Commercial Trade PermitCanceled
2000T00EL01118Commercial Trade PermitWithdrawn
2000T00CM01969Commercial Trade PermitWithdrawn
2000T00BU01011GradingComplete
2000T00CM01549Commercial Addition/Alteration PermitWithdrawn
2000T99CM02091Commercial Addition/Alteration PermitComplete
2000T00BU00675Fire Automatic Extinguishing System PermitComplete
2000T00BU00669Fire Automatic Extinguishing System PermitComplete
2000T00BU00670Fire Automatic Extinguishing System PermitComplete
2000T00BU00671Fire Automatic Extinguishing System PermitComplete
2000T00BU00673Fire Automatic Extinguishing System PermitComplete
1999T99CM05204Commercial Trade PermitComplete
1999T99EL01917Commercial Trade PermitComplete
1999T99CM00862Commercial Addition/Alteration PermitCanceled
1999T99EL01986Commercial Trade PermitWithdrawn
1999T99ME00859Commercial Trade PermitComplete
1999T99CM00715Commercial Trade PermitCanceled
1999T99EL00966Commercial Trade PermitComplete
1999T99EL00812Commercial Trade PermitComplete
1999T99EL00504Commercial Trade PermitComplete
1999T99EL00882Commercial Trade PermitComplete
1999T99EL00884Commercial Trade PermitComplete
1999T99EL00811Commercial Trade PermitComplete
1999T98CM05021Commercial Addition/Alteration PermitWithdrawn
1999T98BU03071Storage Tank PermitCanceled
1999T99CM00675Commercial Addition/Alteration PermitComplete
1999T99EL00512Commercial Trade PermitComplete
1999T99EL00511Commercial Trade PermitComplete
1999T99EL00503Commercial Trade PermitComplete
1999T99ME00231Commercial Trade PermitComplete
1998T98EL02254Commercial Trade PermitWithdrawn
1998T98ME00919Commercial Trade PermitComplete
1998T98CM05314Commercial Addition/Alteration PermitWithdrawn
1998T98BU02751Fire Automatic Extinguishing System PermitComplete
1998T98PL02318Commercial Trade PermitComplete
1998T98PL02317Commercial Trade PermitComplete
1998T98CM05020Commercial Addition/Alteration PermitWithdrawn
1998T98CM04339Commercial Addition/Alteration PermitCanceled
1998T98CM04351Commercial Addition/Alteration PermitComplete
1998T98BU01474Fire Automatic Extinguishing System PermitComplete
1998T98BU01409Commercial Addition/Alteration PermitComplete
1998T98CM01054Commercial Addition/Alteration PermitWithdrawn
1998T98CM01055Commercial Addition/Alteration PermitCanceled
1998T98ME00320Commercial Trade PermitComplete
1998T97CM02238Commercial Trade PermitCanceled
1998T98CM01380Commercial Addition/Alteration PermitComplete
1998T98CM01258Commercial Addition/Alteration PermitComplete
1997T97CM00779Commercial Trade PermitCanceled
1997T97EL01025Commercial Trade PermitCanceled
1997T97EL00567Commercial Trade PermitWithdrawn
1997T97BU00658Fire Automatic Extinguishing System PermitComplete
1997T97EL00116Commercial Trade PermitComplete
1997T97CM00921Commercial Addition/Alteration PermitCanceled
1997T97EL00352Commercial Trade PermitComplete
1997T97CM00701Commercial Addition/Alteration PermitCanceled
1997T97EL00014Commercial Trade PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13216600A — 292 City permits on file from 1997 to 2026 and 13 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.