Electrical permit history — 1881 E Irvington Rd

1881 E Irvington Rd, Tucson — built 1982, with 81 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

1881 E Irvington Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1982 — 1980s multifamily stock · 81 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2000 addition / alteration permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. No permitted service or distribution work shows in the record we read. Gear of this era is generally still supported, but spare capacity drifts with every tenant improvement — worth a load check against the panel schedule before adding major equipment. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2000 addition / alteration permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Concrete Tile. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2015. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    A trade permit was pulled in 2016. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 56,049 sq ft (county building-footprint layer, 19 structures)
Usable for solar, planning estimate
≈ 39,200 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 430 kW — roughly 1,080 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 710,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$57,000–$92,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “I-10 and Valencia Rd”, is about 2.2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13216481A
Year constructed
1982 (assessor record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 100+ Units 2 Story
Building area
81,899 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2024. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2024. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 81 building permits for this parcel dated between 1997 and 2024. By category the work is trade permit (35), annual portable sign compliance (30), zoning compliance (6) and permanent sign (5). 50 of them carry a final inspection; the other 31 were issued, expired or are still open, which is not the same as work completed. There are 11 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13216481A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85714 · Commercial & industrial reports · Homes in 85714 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E IRVINGTON RD hold 1,682 City permits on record, 293 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (92 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025CE-VIO0125-00011Code enforcement caseClosed - Unfounded
2024CE-VIO1124-04382VegetationClosed - Resolved
2024TC-COM-0624-01068Commercial Trade PermitIssued
2023TZ-CMP-0923-00184Zoning ComplianceComplete
2023TC-RES-0623-06178Residential Trade PermitIssued
2023CE-VIO0323-02491Code enforcement caseClosed - Resolved
2022T22CM03840Commercial Addition/Alteration PermitIssued
2021T21DV08519REFUSECOMPLIAN
2021T21DV01835ILLEGAL DUMPINGCOMPLIAN
2020T20OT00593Permanent Sign PermitComplete
2020T20DV07725CLEAN CITIES INITIATIVE PGRMNOVERIFY
2020T20CM05312Commercial Trade PermitExpired
2020T20SA00264Zoning ComplianceApproved
2020T20CM01296Commercial Trade PermitExpired
2020T20DV01478MULTIPLE TYPESNOVERIFY
2020T20DV01098CONDEMNATIONCOMPLIAN
2020T20OT00105Annual Portable Sign ComplianceIssued
2019T19OT01036Annual Portable Sign ComplianceCanceled
2019T19DV05740WEEDSREFERRED
2019T19OT00501Annual Portable Sign ComplianceCanceled
2019T19OT00265Annual Portable Sign ComplianceCanceled
2018T18OT01268Annual Portable Sign ComplianceCanceled
2018T18SA00462Zoning ComplianceComplete
2018T18OT00913Annual Portable Sign ComplianceExpired
2018T18OT00554Annual Portable Sign ComplianceCanceled
2018T18OT00164Annual Portable Sign ComplianceCanceled
2017T17OT01115Annual Portable Sign ComplianceCanceled
2017T17OT00691Annual Portable Sign ComplianceCanceled
2017T17SA00171Zoning ComplianceComplete
2017T17PRE0033Pre-Application ConferenceCanceled
2017T17OT00321Annual Portable Sign ComplianceCanceled
2016T16SA00554Zoning ComplianceComplete
2016T16OT01198Annual Portable Sign ComplianceCanceled
2016T16OT00738Annual Portable Sign ComplianceCanceled
2016T16CM04583Residential Trade PermitComplete
2015T15CM08929Commercial Trade PermitComplete
2015T15CM08436Residential Trade PermitComplete
2015T15CM07655Commercial Trade PermitComplete
2015T15OT01483Annual Portable Sign ComplianceComplete
2015T15OT01311Permanent Sign PermitComplete
2015T15CM04229Commercial Trade PermitComplete
2015T15OT00565Annual Portable Sign ComplianceCanceled
2014T14CM05388Commercial Trade PermitComplete
2014T14OT00867Annual Portable Sign ComplianceCanceled
2014T14DV04002GRAFFITICOMPLIAN
2014T14CM00371Commercial Trade PermitComplete
2014T14OT00091Annual Portable Sign ComplianceCanceled
2013T13OT00315Annual Portable Sign ComplianceCanceled
2012T12OT01351Annual Portable Sign ComplianceCanceled
2012T12OT00432Annual Portable Sign ComplianceCanceled
2011T11EL01666Commercial Trade PermitComplete
2011T11EL01667Commercial Trade PermitComplete
2011T11OT00764Annual Portable Sign ComplianceComplete
2010T10EL02161Commercial Trade PermitComplete
2010T10OT01807Annual Portable Sign ComplianceCanceled
2010T10OT01096Annual Portable Sign ComplianceComplete
2010T10EL00363Commercial Trade PermitComplete
2010T10OT00391Annual Portable Sign ComplianceComplete
2009T09OT02336Annual Portable Sign ComplianceComplete
2009T09EL02188Commercial Trade PermitComplete
2009T09OT01477Annual Portable Sign ComplianceCanceled
2009T09OT00800Annual Portable Sign ComplianceComplete
2009T09OT00370Annual Portable Sign ComplianceComplete
2009T09OT00147Annual Portable Sign ComplianceComplete
2008T08EL02077Commercial Trade PermitComplete
2008T08SA00387Zoning ComplianceComplete
2008T08OT02066Annual Portable Sign ComplianceCanceled
2008T08DV04564ILLEGAL DUMPINGNOVERIFY
2007T07DV10289Permanent Sign PermitComplete
2006T06EL02401Commercial Trade PermitComplete
2006T06EL01939Commercial Trade PermitComplete
2006T06EL01501Residential Trade PermitComplete
2006T06EL00937Commercial Trade PermitComplete
2005T05EL01256Commercial Trade PermitComplete
2005T05EL00335Commercial Trade PermitComplete
2005T05EL00310Commercial Trade PermitComplete
2003T03EL00511Residential Trade PermitComplete
2003T03EL00130Residential Trade PermitComplete
2002T02BU01596Residential DemolitionComplete
2002T02CM02533Commercial Addition/Alteration PermitWithdrawn
2002T02EL01018Commercial Trade PermitCanceled
2002T02EL00893Commercial Trade PermitComplete
2001T01OT00528Permanent Sign PermitComplete
2000T00EL02352Commercial Trade PermitComplete
2000T00CM02533Residential Addition/Alteration PermitComplete
1999T99EL00408Residential Trade PermitComplete
1998T98VL01352Permanent Sign PermitComplete
1998T98EL01451Commercial Trade PermitComplete
1998T98EL01449Commercial Trade PermitComplete
1997T97EL02099Commercial Trade PermitComplete
1997T97EL00637Residential Trade PermitComplete
1997T97EL00205Residential Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13216481A — 81 City permits on file from 1997 to 2024 and 11 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.