Electrical permit history — 755 E Benson Hy
755 E Benson Hy, Tucson — built 1977, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
755 E Benson Hy
Built 1977 — 1970s commercial stock · HVAC 2023 (finaled) · 1 open code case
Permanent link: Electrical permit history for 755 E Benson Hy (aztucsonelectricalsolutions.com/property/132130500/755-e-benson-hy-tucson-az-85713) · Public records last checked 2026-08-16
- Parcel
- 132130500
- Built
- 1977 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Motel
- Parcel size
- 1.96 acres
- Building area
- 30,376 sq ft (assessor record)
- Sewer
- Connection on file (1977) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 firecons permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalCurrentLast permitted 2023 (3 years ago). City inspection record: COT - FCON - Fire - Final approved 2024-06-27. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-COM-0623-01560 — Combine 2 guestrooms into office. Replace exist structural beam. Relocated 2 exist outlets. No change to exist HVAC or plumbing.
- Fire alarm & life safetyCurrentLast permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00218 — Install 2 new Hydrants on Private Fire Line. Install 1 new Gate valve for 1 hydrant. Ex. Gate valve to be utilized for other hydrant.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2023. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Recorded sales (3)
| Date | Price | Type |
|---|---|---|
| 2021-11-01 | $2,804,828 | Warranty Deed |
| 2017-05-24 | $1,450,000 | Warranty Deed |
| 2004-06-03 | $1,150,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-01-07 (TR-UTL-0125-00041) — C.3044808 -ACCESS HH 20387, HH 21068, HH 19487, & MH 19053 FOR SPLICING.
Permit history (20)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-01-07finaled | TR-UTL-0125-00041City permit record | Right-of-Way (ROW) - UtilityC.3044808 -ACCESS HH 20387, HH 21068, HH 19487, & MH 19053 FOR SPLICING | Complete | |
| 2024-11-08finaled | TR-UTL-1124-02134City permit record | Right-of-Way (ROW) - UtilityC.3044808 - ACCESS HH 20387, HH 21068, HH 19487, & MH 19053 FOR SPLICING | Complete | |
| 2024-10-10 | TR-ROW-1024-01191City permit record | Right-of-Way (ROW)This ROW permit will be used to perform geotechnical investigation/boring, existing utility potholing, existing storm drain inspections, as well as native plant inventory and relocation. This work will take place along the I-10 corridor at Park Avenue | Needs resubmittal | |
| 2024-10-09 | TR-ROW-1024-01186City permit record | Right-of-Way (ROW)This ROW permit will be used to perform geotechnical investigation/boring, existing utility potholing, existing storm drain inspections, as well as native plant inventory and relocation. This work will take place along the I-10 corridor at Park Avenue, Kino Parkway, Country Club, Irvington, and Palo Verde. | Void | |
| 2023-12-12finaled | TZ-PMT-1223-00126City permit record | Pool / spaTwo temporary storage boxes of 40'x8' at the hotel premises. The units are not using any existing parking spaces. It is used to store construction materials and hotel furniture. | Complete | |
| 2023-07-26 | TZ-PMT-0723-00083City permit record | Zoning Permit Annual**VOID** DUPLICATE PERMIT Two storage containers used to hold material for some renovations on the property, such as furniture,case goods, material for office renovations | Void | |
| 2023-06-22finaled | TC-COM-0623-01560City permit record | Commercial BuildingCombine 2 guestrooms into office. Replace exist structural beam. Relocated 2 exist outlets. No change to exist HVAC or plumbing. | Complete | |
| 2023-04-28finaled | TR-UTL-0423-01410City permit record | Right-of-Way (ROW) - UtilityNew Fiber Optic Pathway. | Complete |
Show 12 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-04-24 | TR-ROW-0423-00668City permit record | Right-of-Way (ROW)New Fiber Optic Pathway. | Withdrawn | |
| 2022-03-23finaled | T22FC00218City permit record | FIRECONSInstall 2 new Hydrants on Private Fire Line. Install 1 new Gate valve for 1 hydrant. Ex. Gate valve to be utilized for other hydrant. | Final | |
| 2022-02-24finaled | T22OT00141City permit record | SIGN2-CofC on FW + DF | Final | |
| 2021-09-23expired 2023-06-11 | T21CM07641City permit record | Commercial BuildingTI: EXTEND A SUITES (T20DV07859) | Withdrawn | |
| 2019-09-04finaled | T19FC00703City permit record | Addition / alterationFire Alarm & Detection Systems - Install new Fire Alarm Control Panel , smoke detector above panel, pull station at Panel. Connect any exizting devices to new FACP; Fire Alarm Systems - New Sq Ft: 5000; Fire Alarm Systems - # New Stories: 2; Additional Plan Reviews: 1; Additional Inspections: 2 | Complete | |
| 2018-04-09 | T18BU00191City permit record | Pool / spaPOOL | Withdrwn | |
| 2018-01-17expired 2018-07-16 | T18OT00083City permit record | Fence / wall3- CHof COPY (1-FS, 1-DF, 1-WALL) | Expired | |
| 2005-01-25finaled | T05OT00168City permit record | SIGNSIGN:#8394 WESTERN INN MOTEL | Final | |
| 2004-06-02finaled | T04OT01093City permit record | SIGNSIGN:7246 | Final | |
| 2003-04-03finaled | T03OT00552City permit record | SIGNSIGN:5291 | Final | |
| 2002-05-14finaled | T02OT00741City permit record | SIGNSIGN:3999 | Final | |
| 2000-06-28finaled | T00ME00778City permit record | MECHPRESSURE VESSEL CERTIFICATE:TUC-23243 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (58)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-01-27 | CE-VIO0125-00395Code enforcement case | Code enforcement case | Closed - resolved |
| 2024-07-18 | CE-VIO0724-02816Code enforcement case | Vegetation | Citation |
| 2024-06-04 | CE-VIO0624-02151Code enforcement case | Sign | Referred |
| 2024-04-29 | CE-VIO0424-01541Code enforcement case | Work without permit | Closed - unfounded |
| 2023-12-06 | CE-VIO1223-06744Code enforcement case | Refuse | Closed - resolved |
| 2023-10-05 | CE-VIO1023-05917Code enforcement case | Work without permit | Closed - resolved |
| 2022-12-29 | CE-VIO1222-01173Code enforcement case | Work without permit | Closed - resolved |
| 2022-09-23 | T22DV05499Code enforcement case | Refuse | Closed - unfounded |
50 older records are not shown here. — each links to its official file.
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 132130500 — 20 permits on file from 2000 to 2025 (5 sign, 3 right-of-way (row) - utility, 3 right-of-way (row), 2 pool / spa) and 58 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
