Built 1977 — 1970s commercial stock · HVAC 2023 (permitted, completion not confirmed) · 2 open code cases
Permanent link: Electrical permit history for 755 E Benson Hy (aztucsonelectricalsolutions.com/property/132130500/755-e-benson-hy-tucson-az-85713) · Public records last checked 2026-11-13
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 other ifc construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalPermitted — completion not confirmedA 2023 permit specifies this work (the permit description states “Combine 2 guestrooms into office. Replace exist structural beam. Relocated 2 exist outlets. No change to exist HVAC or plumbing.”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. TC-COM-0623-01560 — Combine 2 guestrooms into office. Replace exist structural beam. Relocated 2 exist outlets. No change to exist HVAC or plumbing.
- Fire alarm & life safetyFinaled permit foundLast permitted 2019 (7 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T19FC00703 — Fire Alarm & Detection Systems - Install new Fire Alarm Control Panel , smoke detector above panel, pull station at Panel. Connect any exizting devices to new FACP; Fire Alarm Systems - New Sq Ft: 5000; Fire Alarm Systems - # New Stories: 2; Additional Plan Reviews: 1; Additional Inspections: 2
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth looking at
There are 2 open code enforcement cases on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2023. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
- Routine
A trade permit was pulled in 2000. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.
Solar and energy potential
- Roof footprint
- ≈ 19,118 sq ft (county building-footprint layer)
- Usable for solar, planning estimate
- ≈ 13,400 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 145 kW — roughly 360 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 240,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset at TEP commercial rates
- $19,000–$31,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)
Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Aviation Pkwy and Kino Pkwy”, is about 2 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Get a commercial solar & switchgear analysis
See the property
Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot, so no zone is shown here. That is a gap in this page, not a statement about the property. Check FEMA’s flood map for this address ↗
- Local floodplain (the City of Tucson): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 132130500 ↗ · the City of Tucson ↗
The record behind this read
- Parcel
- 132130500
- Year constructed
- 1977 (assessor record)
- Permitting authority
- Tucson
- Zoning
- C-2
- Property type
- Motel
- Building area
- 30,376 sq ft
The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.
The most recent permit with evidence of issuance is dated 2026. The work was permitted, but final completion is not confirmed. The permit covers only the work described in that record.
What this means for work here
Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.
The most recent permit with evidence of issuance is dated 2026. The work was permitted, but final completion is not confirmed. The permit covers only the work described in that record.
What that reading rests on. The issuing offices hold 22 building permits for this parcel dated between 2000 and 2026. By category the work is permanent sign (6), right-of-way (row) permit - utility (3), pre-application conference (2) and right-of-way (row) permit - general (2). 13 of them carry a final inspection; the other 9 were issued, expired or are still open, which is not the same as work completed. There are 32 code-enforcement cases recorded against the parcel, 2 of which are open. We do not reproduce complaint text — it routinely names people with no connection to the property.
Go straight to the records
Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.
Commercial building (1): 2026 TC-DMO-1026-00173
Code enforcement cases (32): 2026 CE-VIO1026-04204 · 2025 CE-VIO0125-00395 · 2024 CE-VIO0724-02816 · 2024 CE-VIO0624-02151 · 2024 CE-VIO0424-01541 · 2023 CE-VIO1223-06744 · 2023 CE-VIO1023-05917 · 2022 CE-VIO1222-01173 · 2022 T22DV05499 · 2021 T21DV07270 · 2021 T21DV07225 · 2021 T21DV07044 · 2020 T20DV07859 · 2020 T20DV07519 · 2020 T20DV07523 · 2020 T20DV07524 · 2020 T20DV07525 · 2020 T20DV07476 · 2019 T19DV07885 · 2019 T19DV05313 · 2019 T19DV03635 · 2018 T18DV08269 · 2018 T18DV02080 · 2018 T18DV00219 · 2018 T18DV00220 · 2018 T18DV00221 · 2018 T18DV00222 · 2018 T18DV00223 · 2018 T18DV00137 · 2015 T15DV09823 · and 2 older — search the parcel at the office below
City permit record (15): 2026 TP-PRE-0526-00119 · 2026 TP-PRE-0226-00032 · 2023 TZ-PMT-1223-00126 · 2023 TC-COM-0623-01560 · 2022 T21CM07641 · 2022 T22OT00141 · 2022 T22FC00218 · 2019 T19FC00703 · 2018 T18BU00191 · 2018 T18OT00083 · 2005 T05OT00168 · 2004 T04OT01093 · 2003 T03OT00552 · 2002 T02OT00741 · 2000 T00ME00778
Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 132130500. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.
In the public record: All commercial property · Commercial property in 85713 · Commercial & industrial reports · Homes in 85713 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.
How this property compares nearby
Properties on E BENSON HY hold 391 City permits on record, 121 of them since 2022.
Computed from the same public records as this report — counts and years, not an appraisal.
Complete permit record (54 entries)
Every permit and case we hold for this parcel, newest first. Each number links to the official file.
| Year | Number | Type | Status |
|---|---|---|---|
| 2026 | TC-DMO-1026-00173 | Commercial Interior Only Demolition Permit | Issued |
| 2026 | CE-VIO1026-04204 | Code enforcement case | Notice of Violation |
| 2026 | TP-PRE-0526-00119 | Pre-Application Conference | In Review |
| 2026 | TP-PRE-0226-00032 | Pre-Application Conference | Complete |
| 2025 | CE-VIO0125-00395 | Code enforcement case | Closed - Resolved |
| 2025 | record | Right-of-Way (ROW) Permit - Utility | Complete |
| 2024 | record | Right-of-Way (ROW) Permit - Utility | Complete |
| 2024 | record | Right-of-Way (ROW) Permit - General | Needs Resubmittal |
| 2024 | record | ROW Permit - Development/Building | Void |
| 2024 | CE-VIO0724-02816 | Vegetation | Citation |
| 2024 | CE-VIO0624-02151 | Sign | Referred |
| 2024 | CE-VIO0424-01541 | Work without permit | Closed - Unfounded |
| 2023 | TZ-PMT-1223-00126 | Temporary Use Permit | Complete |
| 2023 | CE-VIO1223-06744 | Refuse | Closed - Resolved |
| 2023 | TC-COM-0623-01560 | Commercial Addition/Alteration Permit | Issued |
| 2023 | CE-VIO1023-05917 | Work without permit | Closed - Resolved |
| 2023 | record | Right-of-Way (ROW) Permit - Utility | Complete |
| 2023 | record | Right-of-Way (ROW) Permit - General | Withdrawn |
| 2022 | CE-VIO1222-01173 | Work without permit | Closed - Resolved |
| 2022 | T22DV05499 | Refuse | Closed - Unfounded |
| 2022 | T21CM07641 | Commercial Addition/Alteration Permit | Withdrawn |
| 2022 | T22OT00141 | Permanent Sign Permit | Complete |
| 2022 | T22FC00218 | Other IFC Construction Permit | Complete |
| 2021 | T21DV07270 | MULTIPLE TYPES | REFERRED |
| 2021 | T21DV07225 | WORK WITHOUT PERMITS-RESIDENTL | NOVERIFY |
| 2021 | T21DV07044 | Refuse | Closed - Resolved |
| 2020 | T20DV07859 | Work without permit | Closed - Resolved |
| 2020 | T20DV07519 | EMERGENCY | COMPLIAN |
| 2020 | T20DV07523 | EMERGENCY | COMPLIAN |
| 2020 | T20DV07524 | EMERGENCY | COMPLIAN |
| 2020 | T20DV07525 | EMERGENCY | COMPLIAN |
| 2020 | T20DV07476 | MULTIPLE TYPES | COMPLIAN |
| 2019 | T19DV07885 | PROP MAINT MULTIPLE TYPES | COMPLIAN |
| 2019 | T19FC00703 | Fire Alarm System Permit | Complete |
| 2019 | T19DV05313 | FIRE AT COMMERCIAL BUILDING | COMPLIAN |
| 2019 | T19DV03635 | PROP MAINT MULTIPLE TYPES | COMPLIAN |
| 2018 | T18DV08269 | REFUSE | NOVERIFY |
| 2018 | T18DV02080 | RES: MINIMUM HOUSING | COMPLIAN |
| 2018 | T18BU00191 | Residential Pool/Spa Permit | Withdrawn |
| 2018 | T18OT00083 | Permanent Sign Permit | Expired |
| 2018 | T18DV00219 | MULTIPLE TYPES | COMPLIAN |
| 2018 | T18DV00220 | MULTIPLE TYPES | COMPLIAN |
| 2018 | T18DV00221 | MULTIPLE TYPES | COMPLIAN |
| 2018 | T18DV00222 | MULTIPLE TYPES | COMPLIAN |
| 2018 | T18DV00223 | MULTIPLE TYPES | COMPLIAN |
| 2018 | T18DV00137 | MULTIPLE TYPES | COMPLIAN |
| 2015 | T15DV09823 | RES: MINIMUM HOUSING | NOVERIFY |
| 2014 | T14DV06446 | RES: MINIMUM HOUSING | COMPLIAN |
| 2008 | T08DV02699 | REFUSE | COMPLIAN |
| 2005 | T05OT00168 | Permanent Sign Permit | Complete |
| 2004 | T04OT01093 | Permanent Sign Permit | Complete |
| 2003 | T03OT00552 | Permanent Sign Permit | Complete |
| 2002 | T02OT00741 | Permanent Sign Permit | Complete |
| 2000 | T00ME00778 | Commercial Trade Permit | Complete |
prints this report — permits, comparisons and sources — as a clean document
How this report was built
This is a reading of public records for parcel 132130500 — 22 City permits on file from 2000 to 2026 and 32 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-11-13.
The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.