Electrical permit history — 1001 E Benson Hy

1001 E Benson Hy, Tucson — built 1999, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1001 E Benson Hy

Built 1999 — 1990s commercial stock · 29 permits on record; no permitted panel/service or HVAC work among them

Parcel
132130480
Built
1999 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Misc Commercial
Parcel size
0.98 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 1001 E Benson Hy, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00936 — REMOVE 2 X 10,000 AND 1 X 12,000 UNDERGROUND STORAGE TANKS.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2024-10-09 (TR-ROW-1024-01186) — This ROW permit will be used to perform geotechnical investigation/boring, existing utility potholing, existing storm drain inspections, as well as native plant inventory and relocation. This work will take place along the I-10 corridor at Park Avenue, Kino Parkway, Country Club, Irvington, and Palo Verde..

Permit history (29)

Permit history for this parcel — 8 of 29 records
DateRecordWhatStatusValue
2024-10-09TR-ROW-1024-01186City permit recordRight-of-Way (ROW)This ROW permit will be used to perform geotechnical investigation/boring, existing utility potholing, existing storm drain inspections, as well as native plant inventory and relocation. This work will take place along the I-10 corridor at Park Avenue, Kino Parkway, Country Club, Irvington, and Palo Verde.Void
2024-08-27TZ-PMT-0824-00057City permit recordZoning Permit AnnualConstruction trailerExpired
2020-01-28finaledT20RW00493City permit recordROWSEWER REHABILITATION NO EXACAVTION . CLOSE PARTIAL RIGHT TURN BAY AND ONE OF THE ENTRANCE TO BUSINESS. OTHER DRIVEWAYS AVAILABLE . NOTES: BUSINESS ACCESS MUST BE MAINTAINED AND SIGNEDFinal
2019-12-12finaledT19BU00618City permit recordDemolitionDEMOLITION - T19DV07604Final
2019-11-25finaledT19RW07197City permit recordROWSEWER REHABILITATION NO EXCAVATION. WE WILL BLOCK ONE OF THE DRIVEWAYS AND LEAVE TWO AVAILABLE TO BUSINESSES.Final
2018-07-24finaledT18RW03227City permit recordROWREPAIR OF ASPHALT THAT IS PUSHING/ROLLING AGAINST CONCRETE WHERE THE TWO MEET ON PARK AVE, NEAR THE NE CORNER OF BENSON HWY/ PARK AVEFinal
2017-11-13finaledT17FC00936City permit recordFIRECONSREMOVE 2 X 10,000 AND 1 X 12,000 UNDERGROUND STORAGE TANKS.Final
2016-12-21expired 2017-07-12T16CM09512City permit recordCOMBOREMOVAL OF MANSARD ROOFExpired
Show 21 older records
Permit history for this parcel — remaining 21 records
DateRecordWhatStatusValue
2015-08-17expired 2016-02-17T15BU00940City permit recordTANKSDISPENSER SWAY (LIKE FOR LIKE)Expired
2011-09-29finaledT11OT01867City permit recordSIGN45 DAY BANNER - 9-4-11 TO 10-18-11Final
2011-08-10finaledT11OT01568City permit recordSIGN19794Final
2011-07-20finaledT11OT01429City permit recordSIGNBANNER; 45 DAY; 07/20/11 - 09/03/11Final
2008-08-04expired 2009-06-09T08CM02690City permit recordCOMBOTI:INTERIOR REMODELExpired
2007-07-16finaledT07OT01627City permit recordSIGN13404Final
2007-05-11finaledT07CM01979City permit recordCOMBOAWNING W/ ELECTRICFinal
2007-05-11finaledT07OT01125City permit recordSIGN13106Final
2007-04-04finaledT07OT00795City permit recordSIGN12912Final
2005-03-31finaledT05OT00727City permit recordSIGNSIGN: 8758 CHEVRON USA INCFinal
2005-03-07finaledT05OT00483City permit recordSIGNSIGN:ELECTRIC:8621 CHEVRON USA ., INCFinal
2004-11-02finaledT04BU02675City permit recordTANKSREPLACE:GAS DISPENSERSFinal
1999-09-03expired 1999-11-02T99EX01050City permit recordEXCAVEXCAV:50 LF OF SIDEWALK & APPROACHClosed
1999-08-27expired 2000-02-23T99EL02186City permit recordELECTSIGNS:CIRCUIT:9908125Closed
1999-08-05expired 2000-04-17T99EL01864City permit recordELECTSIGNS:CIRCUIT:9908027 AND 9908028Closed
1999-07-23finaledT99EL01750City permit recordELECTSIGNS:CIRCUIT:9907116Final
1999-06-30expired 2000-04-17T99EL01504City permit recordELECTSIGNS:CIRCUITS:9906131Closed
1999-06-11expired 1999-12-08T99BU01568City permit recordTANKSTANKS:REMOVE 1000 GAL WASTE TANKExpired
1998-08-19P98AN02076City permit recordADDRNEWIssued
1998-08-18finaledT98BU02020City permit recordGRADINGGRADING:CUT 652CY & FILL 611CYFinal
1998-08-18finaledT98CM03559City permit recordCOMBOSERVICE STATION & RESTAURANTC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (13)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 13 records
DateRecordWhatStatus
2022-11-01CE-VIO1122-00099Code enforcement caseVegetationClosed - resolved
2021-10-11T21DV07026Code enforcement caseCode enforcement caseComplian
2020-01-22T20DV00498Code enforcement caseCode enforcement caseComplian
2019-09-30T19DV07604Code enforcement caseCode enforcement caseComplian
2019-07-29T19DV06094Code enforcement caseCode enforcement caseComplian
2019-07-02T19DV05325Code enforcement caseCode enforcement caseComplian
2019-05-20T19DV04156Code enforcement caseCode enforcement caseComplian
2019-01-30T19DV00508Code enforcement caseCode enforcement caseComplian
Show 5 older records
Code enforcement history for this parcel — remaining 5 records
DateRecordWhatStatus
2017-01-31T17DV00411Code enforcement caseGraffitiNoverify
2011-01-19finaledT11FR00181Code enforcement caseCode enforcement caseComplete
2011-01-12finaledT11FR00118Code enforcement caseFireComplete
2007-11-28finaledT07FR02429Code enforcement caseCode enforcement caseComplete
2006-03-31finaledT06FR00606Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 132130480 — 29 permits on file from 1998 to 2024 (8 sign, 4 combo, 4 elect, 3 row) and 13 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.