Electrical permit history — 3333 S Country Club Rd
3333 S Country Club Rd, Tucson — built 1967, with 30 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3333 S Country Club Rd
Built 1967 — 1960s commercial stock · 30 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 3333 S Country Club Rd (aztucsonelectricalsolutions.com/property/13205015n/3333-s-country-club-rd-tucson-az-85713) · Public records last checked 2026-08-17
- Parcel
- 13205015N
- Built
- 1967 (county record)
- Jurisdiction
- Tucson
- Zoning
- I-2
- Assessor use
- Truck Terminal
- Parcel size
- 5.47 acres
- Building area
- 19,580 sq ft (assessor record)
- Sewer
- Connection on file (2009) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2019 (7 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T19FC00059 — REPLACE TWO EXISTING FUEL DISPENSERS WITH GIBARCO HI FLOWS, WITH NEW HANGING HARDWARE. EXISTING DISPENSER SUMPS TO REMAIN.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Most recent permit on record for this parcel: 2026-08-12 (TR-UTL-0826-01340) — PRJ320330-1: Cox to pull thru 333' of existing CATV conduit & bore 73' to install new CATV conduit for system tie..
Permit history (30)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-08-12 | TR-UTL-0826-01340City permit record | Right-of-Way (ROW) - UtilityPRJ320330-1: Cox to pull thru 333' of existing CATV conduit & bore 73' to install new CATV conduit for system tie. | In review | |
| 2024-08-20expired 2025-03-23 | TC-COM-0824-01631City permit record | Commercial BuildingTwo Evap coolers would be installed for an existing building | Issued | |
| 2023-03-17finaled | TR-UTL-0323-01114City permit record | Right-of-Way (ROW) - UtilityP.015054 - 290 ft of bore on S Country Club Rd (North of E 44th St - revision to amend existing permit TR-UTL-1122-00287 | Complete | |
| 2023-02-06 | TR-ROW-0223-00340City permit record | Right-of-Way (ROW)P.015054 - 290 ft of bore on S Country Club Rd (North of E 44th St - revision to amend existing permit TR-UTL-1122-00287 | Needs resubmittal | |
| 2022-12-02finaled | TR-UTL-1222-00360City permit record | Right-of-Way (ROW) - Utilityp.015054-2- ALONG S. COUNTY CLUB RD BORE 290' AND PLACE 1 NEW HANDHOLE. | Complete | |
| 2022-11-16finaled | TR-UTL-1122-00287City permit record | Right-of-Way (ROW) - UtilityP.015054 - ALONG S. COUNTRY CLUB RD ACCESS MH 30758 TO SPLICE CABLE. | Complete | |
| 2022-10-28 | TR-ROW-1022-00016City permit record | Right-of-Way (ROW)P.015054- ALONG S. COUNTY CLUB RD ACCESS MH 30758 TO SPLICE CABLE. | Void | |
| 2022-03-16finaled | T22RW00980City permit record | ROWSTARTING ON THE WEST SIDE OF SOUTH COUNTRY CLUB RD., NORTH OF 44TH ST AT TEP POLE, OVERLASH COAX TO EXISTING STRAND GOING EAST 118’ TO OUT OF ROW. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. 1. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 3. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. AND MUST BE A MINIMUM OF 18-FT HIGH WHEN CROSSING INTERSECTIONS, PAVEMENT AND ALLEYS. 4. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 5. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 6. MAINTAIN PEDESTRIAN ACCESS 7. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813 | Final |
Show 22 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-01-24 | T22CM00514City permit record | Commercial BuildingRun electrical power to modular data server . 480v - 80 amp feed to transformer stepped down to 240v | Expired | |
| 2021-11-18finaled | T21RW05037City permit record | Pool / spaFEDEX FREIGHT FACILITIES MANAGEMENT - TUCSON SERVICE CENTER - SANITARY SEWER IMPROVEMENTS, T21CM00150 EXCAVATING ACROSS COUNTRY CLUB RD FOR NEW HCS TO PROPERTY LINE PER APPROVED DP T21CM00150. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. 1. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 2. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. 3. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. 4. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) 5. ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. 6. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 7. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. 8. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION 9. MAINTAIN PEDESTRIAN ACCESS 10. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813 | Final | |
| 2021-06-07finaled | T21RW02765City permit record | ROWPOTHOLE NEEDED TO COMPELTE LOCATE. 2 5X5 BELLHOLES IN BLACKTOP TO POTHOLE GAS LINE ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. | Final | |
| 2021-05-28 | T21RW02634City permit record | ROWPOTHOLE NEEDED TO COMPELTE LOCATE. 2 5X5 BELLHOLES IN BLACKTOP TO POTHOLE GAS LINE PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. | Void | |
| 2021-04-15finaled | T21RW01802City permit record | Pool / spaEXCAVATING ACROSS COUNTRY CLUB ROAD FOR NEW HCS TO PROPERTY LINE @ 100 LF IN ASPHALT. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. TRENCHES/ PITS CANNOT BE LEFT OPEN OVERNIGHT. MUST BE BACKFILLED AND PATCHED OR PLATED. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. | Final | |
| 2021-01-15 | T21CM00518City permit record | COMBOEXTERIOR LIGHTING REPLACEMENT | Withdrwn | |
| 2021-01-15 | T21RW00234City permit record | ROWEXCAVATE TO EXPOSE COUNTY SEWER LINE TO CONFIRM INVERT ELEVATION. COUNTY SEWER IS LOCATED IN EASEMENT APPROXIMATELY 16' WEST OF SOUTHBOUND SIDEWALK. | Withdrwn | |
| 2021-01-08finaled | T21RW00091City permit record | ROWSTARTING ON THE WEST SIDE OF COUNTRY CLUB RD RISER UP TEP POLE AND OVERLASH 278' GOING NORTH CONTINUE GOING EAST 40' AND RISER DOWN TRENCH / BORE GOING 20' CONTINUE EAST 10' TO OUT OF ROW. | Final | |
| 2021-01-06finaled | T21CM00150City permit record | COMBORerouting sewer line around lift station, tapping and connecting to County sewer main. | Final | |
| 2020-04-15finaled | T20CM02263City permit record | COMBOUPGRADE LIGHTING TO LED | Final | |
| 2019-09-26finaled | T19RW05648City permit record | ROWJOB WILL REQUIRE ACCESS TO MH #30578 TO PLACE FIBER A NOTICE OF TEMPORARYHOLIDAY RESTRICTION APPLIES TO THIS PERMIT AND WILL BE IN EFFECT FROM THANKSGIVING DAY TO JANUARY 2. DUE TO THE INCREASING TRAFFIC VOLUME ON MANY OF THE CITY'S ROADS, IT IS NECESSARY TO RESTRICT LANE CLOSURES ON CERTAIN ROADS DURING THE HOLIDAY SEASON. | Final | |
| 2019-01-24finaled | T19CM00484City permit record | COMBOREMOVE/REPLC 23 EXSISTING FUEL DISPENSERS (FED EX) | Final | |
| 2019-01-23finaled | T19FC00059City permit record | FIRECONSREPLACE TWO EXISTING FUEL DISPENSERS WITH GIBARCO HI FLOWS, WITH NEW HANGING HARDWARE. EXISTING DISPENSER SUMPS TO REMAIN. | Final | |
| 2018-05-21finaled | T18RW02347City permit record | ROWStart Point: From the TEP Pole on the West side of S Country Club Rd and E 44th ST begin adding new strand heading North. Continuing West 95' to TEP , riser down pole. Place 3x3 pothole to install riser. Begin 30' bore/trench heading North , install 2x2'' conduits. Continue East 25' asphalt bore/trench to out of ROW | Final | |
| 2011-10-27finaled | T11PL01792City permit record | PLUMBREPLACE:GAS LINE:BUS | Final | |
| 2011-03-09expired 2011-12-05 | T11CM00742City permit record | COMBOEMERGENCY GENERATOR | Expired | |
| 2009-10-08finaled | T09PL01640City permit record | PLUMBGAS RISER:REPAIR | Final | |
| 2008-09-03finaled | T08BU01600City permit record | TANKSABOVE GROUND STORAGE TANK | Final | |
| 2006-04-25finaled | T06BU00994City permit record | TANKSINSTALL: ABOVE GRADE STORAGE TANK DIESEL | Final | |
| 2005-10-24expired 2005-12-23 | T05EX01215City permit record | EXCAVMANHOLE REPAIR | Closed | |
| 2005-08-17finaled | T05CM04292City permit record | COMBOINST OIL SEPARATOR FOR PRESSURE WASH STATION | Final | |
| 2005-04-20expired 2006-04-20 | T05OT00967City permit record | PEDDLEREL PERO LOCO REGULATED PEDDLER | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (1)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2006-10-19finaled | T06FR02684Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 13205015N — 30 permits on file from 2005 to 2026 (7 row, 6 combo, 4 right-of-way (row) - utility, 2 commercial building) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.