Electrical permit history — 3003 S Country Club Rd

3003 S Country Club Rd, Tucson — built 1969, with 86 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

3003 S Country Club Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1969 — 1960s commercial stock · 86 permits on record; no permitted panel/service or HVAC work among them

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 general operational fire permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 general operational fire permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0924-00802 — To Install One control module on the 1st floor NW Warehouse area
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2020. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Worth confirming

    A pool or spa was permitted in 2006. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2010. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 100,431 sq ft (county building-footprint layer, 2 structures)
Usable for solar, planning estimate
≈ 70,300 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 770 kW — roughly 1,930 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,270,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$102,000–$165,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 1.4 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
13204007A
Year constructed
1969 (assessor record)
Permitting authority
Tucson
Zoning
I-1
Property type
Warehousing
Building area
135,818 sq ft

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 86 building permits for this parcel dated between 1997 and 2025. By category the work is addition / alteration (31), fire automatic extinguishing system (23), trade permit (11) and permanent sign (7). 62 of them carry a final inspection; the other 24 were issued, expired or are still open, which is not the same as work completed. There are 2 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 13204007A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All industrial property · Commercial property in 85713 · Commercial & industrial reports · Homes in 85713 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on S COUNTRY CLUB RD hold 334 City permits on record, 94 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (88 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025recordROW Permit - Special EventsComplete
2025TF-FOP-0825-01127General Operational Fire PermitComplete
2025TC-COM-0725-01388Commercial Addition/Alteration PermitComplete
2025CE-VIO0425-01503Code enforcement caseClosed - Resolved
2025TC-COM-0424-00731Commercial Addition/Alteration PermitIssued
2025TS-PRM-0125-00002Permanent Sign PermitIssued
2024TF-FCP-0924-00802Fire Alarm System PermitComplete
2024TF-FCP-0824-00680Fire Automatic Extinguishing System PermitComplete
2024recordRight-of-Way (ROW) Permit - GeneralComplete
2024TC-CFO-0324-00062Temporary Certificate-of-Occupancy (TCO)Issued
2024TF-FCP-0224-00132Fire Alarm System PermitComplete
2024CE-VIO0324-00922Code enforcement caseClosed - Resolved
2023TF-FCP-1123-01291Fire Automatic Extinguishing System PermitComplete
2023TC-COM-0823-01980Commercial Addition/Alteration PermitComplete
2023TF-FCP-0923-01133Fire Alarm System PermitComplete
2022T22FC00614Fire Automatic Extinguishing System PermitComplete
2022T22CM02438Commercial Addition/Alteration PermitIssued
2022T22CM02174Commercial Addition/Alteration PermitIssued
2021DP19-0129Development PackageComplete
2020T20FC00656Fire Alarm System PermitComplete
2020T20CM03763Residential Solar PermitComplete
2020T20FC00307Fire Automatic Extinguishing System PermitComplete
2020T20CM00532Commercial Addition/Alteration PermitComplete
2019T19PRE0097Pre-Application ConferenceCanceled
2019CWH-19-0129Commercial Water Harvesting OrdinanceActive
2018T18OT00067Permanent Sign PermitInspections Complete
2017T17OT00962Permanent Sign PermitCanceled
2017T17FC00484Fire Alarm System PermitComplete
2015T15BU01137Fire Automatic Extinguishing System PermitComplete
2015T15CM04129Commercial Addition/Alteration PermitWithdrawn
2014T14CM05848Commercial Addition/Alteration PermitCanceled
2014T14CM05778Commercial Trade PermitCanceled
2012T12OT01654Permanent Sign PermitCanceled
2012T12CM00012Commercial Addition/Alteration PermitComplete
2011T11BU01123Commercial Addition/Alteration PermitCanceled
2011T11BU01092Fire Automatic Extinguishing System PermitComplete
2011T11CM02430Commercial Trade PermitCanceled
2011T11CM01542Commercial Addition/Alteration PermitComplete
2011T11BU00127Fire Automatic Extinguishing System PermitComplete
2011T11CM00193Commercial New Building PermitComplete
2010T10CM01510Commercial Addition/Alteration PermitComplete
2010T10EL02103Commercial Trade PermitComplete
2010T10CM02174Commercial Trade PermitComplete
2010T10BU00692Fire Automatic Extinguishing System PermitComplete
2010T10CM01128Commercial Trade PermitComplete
2010T10CM00523Commercial Trade PermitComplete
2010T10BU00275Fire Automatic Extinguishing System PermitComplete
2010T09CM02571Commercial Addition/Alteration PermitCanceled
2009T09BU01162Fire Automatic Extinguishing System PermitComplete
2009T09CM01489Commercial Addition/Alteration PermitWithdrawn
2009T09CM01385Commercial Addition/Alteration PermitComplete
2009T08CM03931Commercial Addition/Alteration PermitCanceled
2008T08BU00747Fire Automatic Extinguishing System PermitComplete
2008T08BU00348Fire Automatic Extinguishing System PermitComplete
2007T07CM03523Commercial Addition/Alteration PermitComplete
2007T07OT00578Permanent Sign PermitComplete
2007T07BU00038Fire Automatic Extinguishing System PermitComplete
2007T06CM06437Commercial Addition/Alteration PermitComplete
2006T06OT02557Permanent Sign PermitComplete
2006T06OT02558Permanent Sign PermitComplete
2006T06BU02083Fire Automatic Extinguishing System PermitComplete
2006T06CM04257Commercial Addition/Alteration PermitComplete
2005T05CM04192Commercial Addition/Alteration PermitWithdrawn
2004T04CM04189Commercial Addition/Alteration PermitWithdrawn
2004T04BU01870Fire Automatic Extinguishing System PermitComplete
2004T04BU00415Fire Automatic Extinguishing System PermitComplete
2003T03CM05284Commercial Addition/Alteration PermitComplete
2003T03BU02058Fire Automatic Extinguishing System PermitComplete
2002T02EL02410Commercial Trade PermitComplete
2001T01CM05488Commercial Addition/Alteration PermitComplete
2001T01CM05326Commercial Addition/Alteration PermitComplete
2001T01CM03347Commercial Addition/Alteration PermitComplete
2000T00CM02237Commercial Trade PermitCanceled
2000T00BU00755Fire Automatic Extinguishing System PermitComplete
2000T00BU00558Fire Automatic Extinguishing System PermitWithdrawn
1999T99CM03456Commercial Addition/Alteration PermitComplete
1999T99BU01884Fire Automatic Extinguishing System PermitComplete
1999T99CM03003Commercial Addition/Alteration PermitComplete
1998T98BU02186Fire Automatic Extinguishing System PermitComplete
1998T98CM03563Commercial Addition/Alteration PermitComplete
1998T98BU01080Fire Automatic Extinguishing System PermitComplete
1998T98CM00430Commercial Addition/Alteration PermitComplete
1998T98EL00214Commercial Trade PermitCanceled
1997T97OT00215Commercial Addition/Alteration PermitWithdrawn
1997T97EL01705Commercial Trade PermitComplete
1997T97CM02494Commercial Addition/Alteration PermitComplete
1997T97PL00911Commercial Trade PermitCanceled
1997T97BU00264Fire Automatic Extinguishing System PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 13204007A — 86 City permits on file from 1997 to 2025 and 2 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-08-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.