Electrical permit history — 2530 S Wilmot Rd

2530 S Wilmot Rd, Tucson — built 1973, with 35 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2530 S Wilmot Rd

Built 1973 — 1970s commercial stock · 35 permits on record; no permitted panel/service or HVAC work among them

Parcel
131132540
Built
1973 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Self-Service Service Station
Parcel size
0.55 acres
Sewer
Connection on file (2003, 2018, 2025) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 2530 S Wilmot Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2000. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2025-04-07$1,300,000Warranty Deed
2001-05-17$412,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-06-01 (TC-CFO-0626-00097) — This project is a proposed fuel center. The fuel center will include a 43' X 88' prefab fuel canopy, a 233 SF kiosk, 5 fuel dispensers and two underground storage tanks. The Site plan is approved through: TD-DEV-0724-00193 The Civil Plans are in review through: TD-DEV-0525-00139 We provided the civil plans as reference in this submittal.

Permit history (35)

Permit history for this parcel — 8 of 35 records
DateRecordWhatStatusValue
2026-06-01expired 2026-08-02TC-CFO-0626-00097City permit recordCertificate of OccupancyThis project is a proposed fuel center. The fuel center will include a 43' X 88' prefab fuel canopy, a 233 SF kiosk, 5 fuel dispensers and two underground storage tanks. The Site plan is approved through: TD-DEV-0724-00193 The Civil Plans are in review through: TD-DEV-0525-00139 We provided the civil plans as reference in this submittalIssued
2026-03-24expired 2026-05-14TR-ROW-0326-00341City permit recordRight-of-Way (ROW)New Driveways, sidewalks and ADA ramps along Wilmot and Golf Links for new Fry's Fuel StationInspections
2026-01-07finaledTR-UTL-0126-00048City permit recordRight-of-Way (ROW) - UtilityEMERGENCY WORK- wo 3196117 2524 s wilmot rd 14-14-24 se hit main at the north west corner of e golf links rd and s wilmot rd in dirt area 6lf/arComplete
2025-12-17TC-FBB-1225-00153City permit recordFactory Built BuildingsWe plan to have (1) 8' x 20' ground set construction office and (1) 8' x 40' storage container for 4 months.Expired
2025-12-16finaledTC-UTL-1225-00122City permit recordUtilitiesConstruction documents for the Fry's #33 fuel center. The site plan was approved though: TD-DEV-0724-00193.Inspections complete
2025-12-03TZ-PMT-1225-00114City permit recordZoning Permit Annual**VOID** We plan to have (1) 8' x 20' ground set construction office and (1) 8' x 40' storage container for 4 months.Void
2025-09-03finaledTF-FCP-0925-00706City permit recordFire ConstructionUST tank permit for the Fry's #33 fuel center.Complete
2025-09-03finaledTF-FOP-0925-01166City permit recordFire OperationalFire operational permit for the Fry's #33 Fuel center.Complete
Show 27 older records
Permit history for this parcel — remaining 27 records
DateRecordWhatStatusValue
2025-08-22expired 2026-03-03TC-DMO-0825-00178City permit recordDemolitionDemolition and removal of old CMU car wash structure and metal canopy structure totaling 3,738sf including associated concrete slab and foundations.Issued
2025-07-29expires 2026-10-12TS-PRM-0725-00318City permit recordSign - Permanentmanufacture and install 5 Illuminated canopy signs and 2 digital fuel displays and 3 monuments signsInspections
2025-05-22expires 2026-11-30TC-COM-0525-01046City permit recordCommercial BuildingThis project is a proposed fuel center. The fuel center will include a 43' X 88' prefab fuel canopy, a 233 SF kiosk, 5 fuel dispensers and two underground storage tanks. The Site plan is approved through: TD-DEV-0724-00193 The Civil Plans are in review through: TD-DEV-0525-00139 We provided the civil plans as reference in this submittalIssued
2025-05-16finaledTD-DEV-0525-00139City permit recordDevelopment PackageRev 1 - Update to basins, concrete, grating, etc, started 03.18.2026 ** Construction documents for the Fry's #33 fuel center. The site plan was approved though: TD-DEV-0724-00193.Inspections complete
2025-05-13TF-FCP-0525-00385City permit recordFire ConstructionVOID - Installing contractor's information needs to be listed on plans & Attach City of Tucson Business License & AZROC. Owner needs to be listed on contacts - UST for the Fry's #33 Fuel CenterVoid
2025-05-13TF-FOP-0525-00695City permit recordFire OperationalVOID - Installing contractor's information needs to be listed on plans & Attach City of Tucson Business License & AZROC. Owner needs to be listed on contacts - Fire operational permit for the Fry's #33 fuel centerVoid
2024-07-03expired 2025-07-03TD-DEV-0724-00193City permit recordDevelopment PackageDP Site Plan submittal for the Fry's #33 Fuel Center.Approved
2023-01-11finaledTR-ROW-0123-00239City permit recordRight-of-Way (ROW)Contractor will be removing & replacing new traffic camera sensors. Duration for this project is approx. (1) one hour. Walkway for pedestrians will be available.Complete
2021-12-10finaledT21RW05227City permit recordROWTEP WILL BE REMOVING 1 POLE IN THE ROW A 2'X2' HOLE 6' DEEP WILL BE BACKFILLED WITHOUT SIDEWALK IMPACT PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF PRECONSTRUCTION MEETING 1. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 2. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 3. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 4. MAINTAIN PEDESTRIAN ACCESS 5. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813Final
2021-01-25finaledT21RW00398City permit recordROWJOB ORDER CONTRACT FOR TRAFFIC SIGNAL AND STREET LIGHT CONSTRUCTION, CONTRACT NO. 181906-02 REPLACE DAMAGED LIGHT POLE AT THE ABOVE ADDRESS BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 48-HOURS PRIOR TO START OF WORK FOR COORDINATION. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS.Final
2019-08-12finaledT19OT00751City permit recordFence / wall1-ILLUM WALL SIGNFinal
2017-08-17finaledT17RW03676City permit recordROWIN ASPHALT NW CORNER OF GOLF LINKS RD AND WILMOT RD TO REPLACE BROKEN VALVEFinal
2017-06-20finaledT17RW02680City permit recordROWEXCAVATE TO REPLACE HIT FIRE HYDRANT IN SIDEWALK AREA IN DIRTFinal
2017-05-10finaledT17CM03704City permit recordCOMBORELO. WMTR./ CONNECT TO NEW MAIN PER TUC. WTR.Final
2012-09-26finaledDP12-0167City permit recordDevelopment PackageSITEComplete
2012-09-26finaledT12CM06009City permit recordCOMBONEW ICE/WATER KIOSKFinal
2012-08-21expired 2013-04-16T12CM05178City permit recordCOMBOTI: CARWASHExpired
2012-08-16expired 2013-02-18T12OT01219City permit recordFence / wall4- C OF C ON WALL & DF SIGNS / 1- NEW WALL SIGN / 1- NEW COURT-YARD FREESTANDING SIGNExpired
2002-07-25expired 2002-09-23T02EX00857City permit recordEXCAVEXCA:INSTALL HCS CONNECTION IN ALLEY 20LFClosed
2002-07-12expired 2003-07-14T02OT01055City permit recordSIGNSIGN:4205Expired
2002-04-10finaledT02CM01847City permit recordAddition / alterationADDITION:CARWASH BAY:EQUIPMENT ROOMFinal
2001-06-15finaledT01EL01572City permit recordELECTELECTRIC:RECONNECT COMMERCIALFinal
2001-03-28expired 2001-12-10T01EL00725City permit recordELECTSIGN:ELECTRIC:2227Expired
2001-03-16expired 2001-12-10T01EL00625City permit recordELECTSIGN:ELECTRIC:2164Expired
2000-02-14finaledT00EL00389City permit recordELECTRECONNECT: ELECTRIC RETAILFinal
1997-07-01finaledT97CM01946City permit recordCOMBOGENERAL REPAIR:ELEC AND PLUMB ONLYFinal
1997-06-20finaledT97OT00106City permit recordC-OF-OC OF O INSPECTION:DOBIES DRIVE THRUC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (6)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 6 of 6 records
DateRecordWhatStatus
2015-06-09T15DV04192Code enforcement caseCode enforcement caseComplian
2015-06-01T15DV04037Code enforcement caseWork without permitCancel
2014-11-07T14DV09330Code enforcement caseCode enforcement caseComplian
2011-08-08T11DV06318Code enforcement caseCode enforcement caseCourtcmp
2008-08-13T08DV07038Code enforcement caseRefuseReferred
2004-08-18T04VL00521Code enforcement caseElectricalComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 131132540 — 35 permits on file from 1997 to 2026 (4 row, 4 combo, 4 elect, 3 development package) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.